• Title/Summary/Keyword: Building disaster prevention

Search Result 272, Processing Time 0.028 seconds

Characteristics of Tsunami Propagation through the Korean Straits and Statistical Description of Tsunami Wave Height (대한해협에서의 지진해일 전파특성과 지진해일고의 확률적 기술)

  • Cho, Yong-Jun;Lee, Jae-Il
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.4
    • /
    • pp.269-282
    • /
    • 2006
  • We numerically studied tsunami propagation characteristics through Korean Straits based on nonlinear shallow water equation, a robust wave driver of the near field tsunamis. Tsunamis are presumed to be generated by the earthquake in Tsuhima-Koto fault line. The magnitude of earthquake is chosen to be 7.5 on Richter scale, which corresponds to most plausible one around Korean peninsula. It turns out that it takes only 60 minutes for leading waves to cross Korean straits, which supports recently raised concerns at warning system might be malfunctioned due to the lack of evacuation time. We also numerically obtained the probability of tsunami inundation of various levels, usually referred as tsunami hazard, along southern coastal area of Korean Peninsula based on simple seismological and Kajiura (1963)'s hydrodynamic model due to tsunami-generative earthquake in Tsuhima-Koto fault line. Using observed data at Akita and Fukaura during Okushiri tsunami in 1993, we verified probabilistic model of tsunami height proposed in this study. We believe this inundation probability of various levels to give valuable information for the amendment of current building code of coastal disaster prevention system to tame tsunami attack.

Mapping Technique for Flood Vulnerable Area Using Surface Runoff Mechanism (지표유출메커니즘을 활용한 홍수취약지구 표출 기법)

  • LEE, Jae-Yeong;HAN, Kun-Yeun;KIM, Hyun-Il
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.181-196
    • /
    • 2019
  • Floods can be caused by a variety of factors, and the main cause of floods is the exceeding of urban drainage system or river capacity. In addition, rainfall frequently occurs that causes large watershed runoff. Since the existing methodology of preparing for flood risk map is based on hydraulic and hydrological modeling, it is difficult to analyse for a large area because it takes a long time due to the extensive data collection and complex analysis process. In order to overcome this problem, this study proposes a methodology of mapping for flood vulnerable area that considered the surface runoff mechanism. This makes it possible to reduce the time and effort required to estimate flood vulnerabilities and enable detailed analysis of large areas. The target area is Seoul, and it was confirmed that flood damage is likely to occur near selected vulnerable areas by verifying using 2×2 confusion matrix and ROC curve. By selecting and prioritizing flood vulnerable areas through the surface runoff mechanism proposed in this study, the establishment of systematic disaster prevention measures and efficient budget allocation will be possible.

Behavior Characteristics of Micropile Following the Embedded Condition (근입조건에 따른 마이크로파일의 거동특성)

  • Bang, Seongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.6
    • /
    • pp.19-25
    • /
    • 2020
  • In the recent downtown works, there are frequent cases where the work on existing piles is impossible due to the influence from lack of space and surrounding environment. In such cases, there has been growing cases of using the micropile method that is available to work with the small equipment and asserts the bearing capacity of the existing piles. The micropile method is a type of drilled shaft with the diameter of a pile to be around 75 mm~300 mm that, even for a case where it has certain surrounding structure, foundation and spatial obstacle, there is almost no work difficulty and the work is feasible under all types of soil conditions. In addition, the work can be done in places where the ceiling of the building is low with less vibration and noise in the work process that such method is significantly used for foundation reinforcement of existing buildings. With respect to the motion characteristics that are changed depending on the foundational characteristics or when the micropile is applied with compression or tensile force, there is very few studies conducted. Therefore, under this study, through the data analysis of the field loading test regarding the micropile worked in the fields, it clarifies the settlement and characteristics of bearing capacity following the embedded condition of the ingredients and piles that consist the foundation if the compression and tensile force are applied to the micropile, and by facilitating the statistical analysis program, SAS, to carry out the analysis on the main elements influencing on settlement of the micropile and bearing capacity.

Characteristics study on fire-resistant paint used by TGA-IR (TGA-IR을 사용한 내화 도료의 특성에 관한 연구)

  • Cho, Nam-Wook;Shin, Hyun-Jun;Cho, Won-Bo;Lee, Seong-Hun;Rie, Dong-Ho;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.168-172
    • /
    • 2011
  • The iron frame of building could be collapsed or bent at $500^{\circ}C$. Therefore the fire-resistant paint should be applied for safety. This study performed the comparative analysis to show the characteristics of fireresistant paint. And then 12 products of fire resistant paint and 6 products of paints were used as samples. And the samples were analyzed by TGA (Thermogravimetric Analyzer) as analyzer for measuring the variation of weight on temper of weight by heating. When TGA analyzer could measure the variatiature, and FT-IR was measured for analyze gas components on variation on of weight by heating on 12 products of fire resistance, the samples showed to decrease 40% of weight to $800^{\circ}C$, and because paints had 50% to 40% of loss weight, it showed to be equal with loss weight of fire resistance paint on high temperature or was lower loss weight than it of fire resistance paints. However number 6 sample of fire resistance paints could show to decrease 20% of total weight on $800^{\circ}C$. And then in the case of FT-IR, fire resistance paints could show to have the high intensity of $CO_2$ spectrum as complete combustion. However paints could show to have the lower intensity of $CO_2$ spectrum, have the higher intensity of water spectrum. Therefore the TGA graph of result could be much different until $250^{\circ}C$. When it was burned, FT-IR spectrum could show to confirm the characteristics of fire resistance paints, and the characteristic could be confirmed on inorganic paint of fire resistance by weight loss of TGA.

Fire Safety Analysis of Fire Suppression System for Aircraft Maintenance Hangar Using Fault Tree Method (Fault Tree를 활용한 항공기 격납고 소화시스템의 화재 안전성 분석)

  • Lee, Jong-Guk
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.67-73
    • /
    • 2017
  • An aircraft maintenance hangar is a building that stores, maintains, and inspects expensive aircraft. The frequency of fire occurrence is low, but the resulting human and material damage can be very serious. Therefore, in this study, we conducted a qualitative analysis of the fire safety of the currently operating fire suppression systems for aircraft maintenance hangars using the Fault Tree method, and then performed a quantitative analysis using the failure rate data for the derived basic events and analyzed the importance of the minimal cut sets. As a result of the qualitative analysis by the minimal cut set, it was found that there were 14 accident paths that could be expanded to a large fire, due to the fire control failure of the aircraft hangar fire suppression system. The quantitative analysis revealed that, the probability of the fire expanding into a large one is $2.08{\times}E-05/day$. The analysis of the importance of the minimal cut set shows that four minimal cut sets, namely the fire detector and foam head action according to the zone and blocking of the foam by the aircraft wing and the fire plume, had the same likelihood of causing the fire to develop into a large one, viz. 24.95% each, which together forms the majority of the likelihood. It was confirmed for the first time by fault tree method that the fire suppression system of aircraft maintenance hangars is not suitable for fires under the aircraft wings and needs to be improved.

Verification on the Design Formulas of Apron Length by Scour Analysis at Weir Downstream (보 하류부 세굴 분석을 통한 물받이공 길이 설계 공식 검토)

  • Ko, Dongwoo;Lee, Changhun;Kang, Joongu
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.2
    • /
    • pp.83-89
    • /
    • 2020
  • This hydraulic study analyzed the scour effect at fixed downstream weirs based on the changes in the upstream bed slope. The study was performed using six different bed slopes, that is, 0%, 2%, 3%, 4%, 7%, and 10% at 0.117 ㎥/s in all cases. The scour depth, scour length, and scour volume were measured using a broadband laser scanner to quantitatively analyze the scour at the downstream weir. This study also examined the adequacy of the designed apron length by comparatively analyzing the results of the scour experiments and the apron length calculated using conventional design standard formulas. The analysis of the local scour effect at the downstream weir showed that scour length and scour depth increased as the bed slope became steeper. A comparison between the results of the scour experiment and that of the conventional design formulas showed that both formulas of the National Construction Research Institute and the Bligh were distributed within the allowable values when there was no upstream bed slope. However, as the bed slope upstream of the weir gradually increased, the scour lengths of the apron deviated slightly from the values obtained from the conventional design formulas.

Identifying Specifications of Flat Type Signboards Using a Stereo Camera (스테레오 카메라를 이용한 판류형 간판의 규격 판별)

  • Kwon, Sang Il;Kim, Eui Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.1
    • /
    • pp.69-83
    • /
    • 2020
  • Signboards are standardized according to national legislation for the safety of pedestrians and disaster prevention in urban areas. Signboards should be installed according to the standard. However, it is not easy to manage the signboards systematically due to the number of signboards that have been installed for a long time and frequently changing stores. In this study, we proposed a methodology for distinguishing signboards that deviated from the standard. To this end, the signboard was photographed using a stereo camera, and then the three-dimensional coordinates of the signboard were determined from the signboard image to calculate the signboard's horizontal and vertical dimensions to determine the signboard's specifications. In order to determine the interior and relative orientation parameters of the stereo camera, an outdoor three-dimensional building was used as the test field. Then, the image coordinates of four vertices of the signboard were extracted from the signboard image taken from about 15m ~ 22m distance using deep learning. After determining the signboard's three-dimensional coordinates by using the interior and relative orientation parameters of the stereo camera and the image coordinates of the four vertices of the signboard, the horizontal and vertical sizes of the signboard were calculated, resulting in an error of about 2.7cm on average. The specifications for the ten flat-type signboards showed that all of the horizontal sizes were compliant with the specifications, but the vertical sizes exceeded about 36.5cm on average. Through this, it was found that maintenance of flat-type signboards is needed overall.

Causal Relationship between the Risk-inducing Factors and Safety Inspection and Accident Reduction in Small Construction Sites (소규모 건설현장에서 위험유발요인과 안전점검이 재해 저감 대책에 미치는 인과 관계)

  • Moon, Pil-jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.55-70
    • /
    • 2020
  • This study aims to identify the influence of risk-inducing factors and safety inspection on the measures of reducing accidents among workers of building structures in small construction sites. The result can be summarized as follows: First, as for the influence of risk-inducing factors on human factors, preparation for work, disintegrating molds, taking follow-up measures, and keeping records, have statistically significant influences. Therefore, it can be said that safety inspection has a partial mediating effect in the relationship between risk-inducing factors and human factors. Second, as for the influence of risk-inducing factors on facility factors, preparation for work, and taking follow-up measures influenced significantly. This indicates that safety inspection has a partial mediating effect in the relationship between risk-inducing factors and facility factors. Third, as for the influence of risk-inducing factors on management factors, the installation of shores and risk assessment are found to have significant effects. This shows that safety inspection has a partial mediating effect in the relationship between risk-inducing factors and management factors. Fourth, the influence of risk-inducing factors on work factors was significant only in the installation of shores. This indicates that safety inspection has a completely mediating effect in the relationship between risk-inducing factors and work factors. Finally, in the relationship between risk-inducing factors and accident reduction measures, preparation for work, installation of shores, and taking follow-up measures showed significantly positive influences. In contrast, keeping records has a significant negative influence. Thus, safety inspection has a partial mediating effect in the relationship between risk-inducing factors and management factors.

The Evaluation of Architectural Density on Urban District using Airborne Laser Scanning Data (항공레이저측량 자료를 이용한 시가지 건축밀도 평가에 관한 연구)

  • Lee, Geun-Sang;Koh, Deuk-Koo;Cho, Gi-Sung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.6 no.3
    • /
    • pp.95-106
    • /
    • 2003
  • This study evaluated the architectural density of urban district using airborne laser scanning(ALS) that is a method used in urban planning, water resources and disaster prevention with high interest recently. First, digital elevation model(DEM) and digital surface model(DSM) was constructed from Light detection and ranging(LiDAR). For getting the height of building, ZONALMEAN filter was used in DEM and ZONALMAJORITY filter was used in DSM. This study compared the floor from filtering with the floor from survey and got standard error, which is ${\pm}0.199$ floor. Also, through the overlay and statistical analysis of total-area layer and zone layer, we could present floor area ratio by zone. As a result of comparison with floor area ratio between airborne laser scanning data and survey data, the standard error of floor area ratio shows ${\pm}2.68%$. Therefore, we expect that airborne laser scanning data can be a very efficient source to decision makers who set up landuse plan in near future.

  • PDF

Effect of N Value and Pile Length Ratio on Bearing Capacity Distribution of Cohesionless Soil (사질토 지반에서 N값과 말뚝의 길이비가 지지력 분담 특성에 미치는 영향)

  • Lee, Kwang-Wu;You, Seung-Kyong;Han, Jung-Geun;Park, Jeong-Jun;Kim, Ki-Sung;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.65-73
    • /
    • 2020
  • This study describes the evaluation results of pile length ratio and N value on the bearing capacity of drilled shafts in cohesionless soil. The bearing capacity ratio in Meyerhof's formula is affected only by the length ratio, and it is equally evaluated a sharing ratio of the end bearing capacity and the skin friction. NAVFAC's formula shows that the pile length influences both end bearing capacity and the skin friction, but pile length is also found to be a more influence factor on the end bearing capacity. Especially, it was found that the effect of pile length factor was larger than the effect of N value and pile diameter. FHWA's formula was evaluated to reflect the influence factor by skin friction more positively than other formulas at calculation the bearing capacity. It was also confirmed that the influence of the skin friction is larger when the ultimate bearing capacity is evaluated.