An efficient optimization approach for wind interference effect on octagonal tall building

  • Kar, Rony;Dalui, Sujit Kumar;Bhattacharjya, Soumya
    • Wind and Structures
    • /
    • 제28권2호
    • /
    • pp.111-128
    • /
    • 2019
  • In this paper an octagon plan shaped building (study building) in presence of three square plan shaped building is subjected to boundary layer wind flow and the interference effects on the study building is investigated using Computational fluid dynamics. The variation of the pressure coefficients on different faces of the octagon building is studied both in isolated and interference conditions. Interference Factors (IF) are calculated for different faces of the study building which can be a powerful tool for designing similar plan shaped buildings in similar conditions. A metamodel of the IF, in terms of the distances among buildings is also established using Response Surface Method (RSM). This set of equations are optimized to get the optimum values of the distances where the IF is unity. An upstream Interference zone for this building setup and wind environment is established from these data. Uncertainty principle is also utilised to determine the optimum positions of the interfering buildings considering the uncertain nature of wind flow for minimum interference effect. The proposed procedure is observed to be computationally efficient in deciding optimum layout at buildings often required in city planning. The results show that the proposed RSM-based optimization approach captures the interference zone accurately with substantially less number of experiments.

Improved stress recovery for elements at boundaries

  • Stephen, D.B.;Steven, G.P.
    • Structural Engineering and Mechanics
    • /
    • 제5권2호
    • /
    • pp.127-135
    • /
    • 1997
  • Patch recovery attempts to derive a more accurate stress filed over a particular element than the finite element shape function used for that particular element. Elements that have a free edge being the boundary to the structure have particular stress relationship that can be incorporated to the stress field to improve the accuracy of the approximation.

Simplification of LIDAR Data for Building Extraction Based on Quad-tree Structure

  • Du, Ruoyu;Lee, Hyo Jong
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2011년도 추계학술발표대회
    • /
    • pp.355-356
    • /
    • 2011
  • LiDAR data is very large, which contains an amount of redundant information. The information not only takes up a lot of storage space but also brings much inconvenience to the LIDAR data transmission and application. Therefore, a simplified method was proposed for LiDAR data based on quad-tree structure in this paper. The boundary contour lines of the buildings are displayed as building extraction. Experimental results show that the method is efficient for point's simplification according to the rule of mapping.

콘크리트 내부 온습도 추정 및 탄산화 깊이 예측 (Estimation of Thermal Humidity Inside Concrete and Prediction of Carbonation Depth)

  • 박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2021
  • The temperature and humidity inside concrete affects the depth of carbonation. In this study, the temperature and humidity inside concrete were predicted by the numerical method under the boundary conditions of ambient temperature, humidity, solar radiation, and wind. Using the results of the thermal humidity analysis, diffusion of carbon dioxide and the reaction of cement hydration products were calculated for carbonation depth.

  • PDF

재난변동풍하중을 받는 고층건물의 변동풍압분포의 평가 (Estimate of the Fluctuating Pressure Distribution of Tall Building under Hazard Fluctuating Wind Load)

  • 황진철
    • 한국방재안전학회논문집
    • /
    • 제6권2호
    • /
    • pp.49-56
    • /
    • 2013
  • 본 논문에서는 재난변동풍하중을 받는 고층건물의 예비설계과정에서 필요로 하는 자료를 얻기 위하여 경계층풍동 실험을 실시했다. 먼저 본 실험에 앞서 경계층풍동내의 자연풍을 얻기 위하여 확산장치를 이용했고, 이로부터 평균풍속 수직분포, 난류강도, 파워스펙트럼으로 입증했으며, 이 후 변장비 1:2 강체모형을 이용 경계층풍동실험을 실시한 결과로부터 다음과 같은 결론을 얻을 수 있었다. 1. 경계층풍동에서의 평균풍속 및 난류강도의 수직분포가 자연풍과 같이 잘 실현되었다. 2. 변동풍속 스펙트럼은 Von Karman spectrum과 비교한 결과 잘 일치했다. 3. 변동압력 스펙트럼에서 풍상면의 피크분포는 0.01-0.1 Hz영역에서 발생했고, 풍후면은 0.1 Hz영역에서 발생했다. 4. 자기상관계수는 재난변동풍하중의 작용시간이 증가하면 정성확률과정으로 분포하는 사실을 알 수 있었다.

Investigation on interlaminar shear stresses in laminated composite beam under thermal and mechanical loading

  • Murugesan, Nagaraj;Rajamohan, Vasudevan
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.583-601
    • /
    • 2015
  • In the present study, the combined effects of thermal and mechanical loadings on the interlaminar shear stresses of both moderately thin and thick composite laminated beams are numerically analyzed. The finite element modelling of laminated composite beams and analysis of interlaminar stresses are performed using the commercially available software package MSC NASTRAN/PATRAN. The validity of the finite element analysis (FEA) is demonstrated by comparing the experimental test results obtained due to mechanical loadings under the influence of thermal environment with those derived using the present FEA. Various parametric studies are also performed to investigate the effect of thermal loading on interlaminar stresses generated in symmetric, anti-symmetric, asymmetric, unidirectional, cross-ply, and balanced composite laminated beams of different stacking sequences with identical mechanical loadings and various boundary conditions. It is shown that the elevated thermal environment lead to higher interlaminar shear stresses varying with the stacking sequence, length to thickness ratio, ply orientations under identical mechanical loading and boundary conditions of the composite laminated beams. It is realized that the magnitude of the interlaminar stresses along xz plane is always much higher than those of along yz plane irrespective of the ply-orientation, length to thickness ratios and boundary conditions of the composite laminated beams. It is also observed that the effect of thermal environment on the interlaminar shear stresses in carbon-epoxy fiber reinforced composite laminated beams are increasing in the order of symmetric cross-ply laminate, unidirectional laminate, asymmetric cross-ply laminate and anti-symmetric laminate. The interlaminar shear stresses are higher in thinner composite laminated beams compared to that in thicker composite laminated beams under all environmental temperatures irrespective of the laminate stacking sequence, ply-orientation and boundary conditions.

농촌마을 담장자원 조사연구 (A Study on State of Boundary Barriers Resources in Rural Villages)

  • 임종현;최수명;조중현
    • 농촌계획
    • /
    • 제18권1호
    • /
    • pp.17-28
    • /
    • 2012
  • Functional mismatch and thought and plan-less material use of recently built boundary barriers in rural areas should greatly degrade their amenity value as one of linear villagescapes, but, their present state-of-art basically necessary for problem-solving had never surveyed up to now. From this point of view, this study tried to investigate present stock quantities and qualities of boundary barriers in rural areas by sample studies on 21 case villages(7 types ${\times}$ 3 cases) and comparative analysis between the planned or improved and nots. Wall type was absolutely dominated in the structural terms, of which more than half was used cement block as building material and, therefore, grey-colored. More than half of total barrier length were fully shielded, while relatively partially shielded in the mountainous villages in open space and 'Cultural villages' with closed housing structures. Free standing style of barriers was shown along over two thirds of their total length, although not more than half in planned reclaimed villages. Especially, because of one-sided wall type structure, mismatched over-shieldness and poorer maintenance condition of the boundary barriers in peri-urban villages, there should be provided with very intensive improvement efforts for amenity barriers.

Downburst versus boundary layer induced wind loads for tall buildings

  • Kim, Jongdae;Hangan, Horia;Eric Ho, T.C.
    • Wind and Structures
    • /
    • 제10권5호
    • /
    • pp.481-494
    • /
    • 2007
  • Downbursts are transient phenomena that produce wind profiles that are distinctly different from synoptic boundary layers. Wind field data from Computational Fluid Dynamics (CFD) simulations of isolated downburst-like impinging jets, are used to investigate structural loads of tall buildings due to these high intensity winds. The base shear forces and base moments of tall buildings of heights between 120 and 250 m produced by downburst winds of various scales are compared with the forces from the equivalent boundary layer gust winds, with matched 10-metre wind velocity. The wind profiles are mainly functions of the size of the downburst and the radial distance from the centre of the storm. Wind forces due to various downburst profiles are investigated by placing the building at different locations relative to the storm center as well as varying the size of the downburst. Overall it is found that downbursts larger than approx. 2,000 m in diameter might produce governing design wind loads above those from corresponding boundary layer winds for tall buildings.

Wind pressure provisions for gable roofs of intermediate roof slope

  • Stathopoulos, Theodore;Wang, Kai;Wu, Hanqing
    • Wind and Structures
    • /
    • 제4권2호
    • /
    • pp.119-130
    • /
    • 2001
  • The paper addresses the suitability of wind pressure coefficients specified in contemporary design standards and codes of practice for gable roofs of intermediate slope (roof angle $10^{\circ}-30^{\circ}$). In a recent research study, a series of low building models with different roof slopes in this intermediate range were tested in a boundary layer wind tunnel under simulated open country terrain conditions. This was different from the original study in the 70's, which produced the current provisions on the basis of a model tested only for a single roof slope (4:12) in this range. The results of the study suggest that a modification to the American wind provisions would be warranted to make them more representative of the true local and area-averaged wind loads imposed on gable roofs of intermediate slope.