• 제목/요약/키워드: Building bioclimatic chart

검색결과 3건 처리시간 0.027초

건물생체기후도를 이용한 자연형 기후설계 도구 개발 및 활용 (Development and Application of Passive Climatic Design Tool Using Building Bioclimatic Chart for Energy Efficient Building)

  • 송승영
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.153-160
    • /
    • 2004
  • It is essential to know climatic characteristics of the site for energy efficient building design. However, it is difficult to obtain a climate data. Even though the climate data is obtained, it is difficult to be applied to the building design since it is usually consisted of just series of numbers. Also, designers cannot know the effective climatic design strategies suitable for the site with ease. Thus, this study aims to develope the climatic design tool working on the personal computer operated by windows 95/98/2000/XP. WYEC weather data and building bioclimatic chart are adopted for the climate analysis. Climatic Characteristics(distributions of the dominant factors, bioclimatic needs, needs to each passive design strategy, and the order of priority, etc.) of Seoul are analysed and presented as an example. Also, passive climatic design process making use of this tool is presented.

건물의 전기부하특성에 따른 BIPV시스템의 부하매칭에 관한 연구 (A Study on BIPV system generation matching by electricity load characteristic of Building)

  • 박재완;신우철;김대곤;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.67-74
    • /
    • 2013
  • These days, although thermal energy is decreasing, electric energy is increasing in building. Also, it is very important to research and distribute BIPV(Building Integrated photovoltaic) because our society consider electricity more significant than other energy in building. Therefore, in this paper, our research team analyzed difference between BIPV yield and building energy consumption through experimental research. As a result, yearly building energy consumption was 104,602.4kWh and BIPV yield was 105,267kWh. And then, totally counterbalanced time took up 26%, reduced electric load time took up 16%. In other words, peak load could be reduced up to 42% by BIPV. As a result, yearly building energy consumption was 104,602.4kWh and BIPV yield was 105,267kWh. And then, totally counterbalanced time took up 26%, reduced electric load time took up 16%. In other words, peak load could be reduced up to 42% by BIPV.

접시형 태양열 집광 시스템을 이용한 열화학 사이클의 수소생산 (TWO-STEP THERMOCHEMICAL CYCLES FOR HYDROGEN PRODUCTION WITH DISH TYPE SOLAR THERMAL SYSTEM)

  • 권해성;오상준;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.169-176
    • /
    • 2011
  • The two-step water splitting thermochemical cycle is composed of the T-R (Thermal Reduction)and W-D (Water Decomposition)steps. The mechanism of this cycle is oxidation-reduction, which produces hydrogen. The reaction temperature necessary for this thermochemical cycle can be achieved by a dish-type solar thermal collector (Inha University, Korea). The purpose of this study is to validate a water splitting device in the field. The device is studied and fabricated by Kodama et al (2010, 2011). The validation results show that the foam device, when loaded with $NiFe_2O_4/m-ZrO_2$powder, was successfully achieved hydrogen production with 9 (10 with a Xe-light solar simulator, 2009, Kodama et al.) repeated cycles under field conditions. Two foam device used in this study were tested for validation before an experiment was performed. The lab scale ferrite-conversion rate was in the range of 24~76%. Two foam devices were designed to for structural stability in this study. In the results of the experiments, the hydrogen percentage of the weight of each foam device was 7.194 and $9.954{\mu}mol\;g^{-1}$ onaverage, and the conversion rates 4.49~29.97 and 2.55~58.83%, respectively.

  • PDF