• Title/Summary/Keyword: Building Structure Standards

Search Result 146, Processing Time 0.028 seconds

Seismic assessment of transfer plate high rise buildings

  • Su, R.K.L.;Chandler, A.M.;Li, J.H.;Lam, N.T.K.
    • Structural Engineering and Mechanics
    • /
    • v.14 no.3
    • /
    • pp.287-306
    • /
    • 2002
  • The assessment of structural performance of transfer structures under potential seismic actions is presented. Various seismic assessment methodologies are used, with particular emphasis on the accurate modelling of the higher mode effects and the potential development of a soft storey effect in the mega-columns below the transfer plate (TP) level. Those methods include response spectrum analysis (RSA), manual calculation, pushover analysis (POA) and equivalent static load analysis (ESA). The capabilities and limitations of each method are highlighted. The paper aims, firstly, to determine the appropriate seismic assessment methodology for transfer structures using these different approaches, all of which can be undertaken with the resources generally available in a design office. Secondly, the paper highlights and discusses factors influencing the response behaviour of transfer structures, and finally provides a general indication of their seismic vulnerability. The representative Hong Kong building considered in this paper utilises a structural system with coupled shear walls and moment resisting portal-frames, above and below the TP, respectively. By adopting the wind load profile stipulated in the Code of Practice on Wind Effects: Hong Kong-1983, all the structural members are sized and detailed according to the British Standards BS8110 and the current local practices. The seismic displacement demand for the structure, when built on either rock or deep soil sites, was determined in a companion paper. The lateral load-displacement characteristic of the building, determined herein from manual calculation, has indicated that the poor ductility (brittle nature) of the mega-columns, due mainly to the high level of axial pre-compression as found from the analysis, cannot be effectively alleviated solely by increasing the quantity of confinement stirrups. The interstorey drift demands at lower and upper zones caused by seismic actions are found to be substantially higher than those arising from wind loads. The mega-columns supporting the TP and the coupling beams at higher zones are identified to be the most vulnerable components under seismic actions.

Experimental study on Chinese ancient timber-frame building by shaking table test

  • Zhang, Xi-Cheng;Xue, Jian-Yang;Zhao, Hong-Tie;Sui, Yan
    • Structural Engineering and Mechanics
    • /
    • v.40 no.4
    • /
    • pp.453-469
    • /
    • 2011
  • A one-story, wooden-frame, intermediate-bay model with Dou-Gon designed according to the Building Standards of the Song Dynasty (A.D.960-1279), was tested on a unidirectional shaking table. The main objectives of this experimental study were to investigate the seismic performance of Chinese historic wooden structure under various base input intensities. El Centro wave (N-S), Taft wave and Lanzhou wave were selected as input excitations. 27 seismic geophones were instrumented to measure the real-time displacement, velocity and acceleration respectively. Dynamic characteristics, failure mode and hysteretic energy dissipation performance of the model are analyzed. Test results indicate that the nature period and damping ratio of the model increase with the increasing magnitude of earthquake excitation. The nature period of the model is within 0.5~0.6 s, the damping ratio is 3~4%. The maximum acceleration dynamic magnification factor is less than 1 and decreases as the input seismic power increases. The frictional slippage of Dou-Gon layers (corbel brackets) between beams and plates dissipates a certain amount of seismic energy, and so does the slippage between posts and plinths. The mortise-tenon joint of the timber frame dissipates most of the seismic energy. Therefore, it plays a significant part in shock absorption and isolation.

Performance-based and damage assessment of SFRP retrofitted multi-storey timber buildings

  • Vahedian, Abbas;Mahini, Seyed Saeed;Glencross-Grant, Rex
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.3
    • /
    • pp.269-282
    • /
    • 2015
  • Civil structures should be designed with the lowest cost and longest lifetime possible and without service failure. The efficient and sustainable use of materials in building design and construction has always been at the forefront for civil engineers and environmentalists. Timber is one of the best contenders for these purposes particularly in terms of aesthetics; fire protection; strength-to-weight ratio; acoustic properties and seismic resistance. In recent years, timber has been used in commercial and taller buildings due to these significant advantages. It should be noted that, since the launch of the modern building standards and codes, a number of different structural systems have been developed to stabilise steel or concrete multistorey buildings, however, structural analysis of high-rise and multi-storey timber frame buildings subjected to lateral loads has not yet been fully understood. Additionally, timber degradation can occur as a result of biological decay of the elements and overloading that can result in structural damage. In such structures, the deficient members and joints require strengthening in order to satisfy new code requirements; determine acceptable level of safety; and avoid brittle failure following earthquake actions. This paper investigates performance assessment and damage assessment of older multi-storey timber buildings. One approach is to retrofit the beams in order to increase the ductility of the frame. Experimental studies indicate that Sprayed Fibre Reinforced Polymer (SFRP) repairing/retrofitting not only updates the integrity of the joint, but also increases its strength; stiffness; and ductility in such a way that the joint remains elastic. Non-linear finite element analysis ('pushover') is carried out to study the behaviour of the structure subjected to simulated gravity and lateral loads. A new global index is re-assessed for damage assessment of the plain and SFRP-retrofitted frames using capacity curves obtained from pushover analysis. This study shows that the proposed method is suitable for structural damage assessment of aged timber buildings. Also SFRP retrofitting can potentially improve the performance and load carrying capacity of the structure.

A Study on the Visibility Ratio Analysis Technique for Establishing the Cultural Property Protective Zone (문화재 보호구역 설정을 위한 가시율 분석 기법에 관한 연구)

  • Park, Eun-Hee;Kim, Tae-Han;Lee, Jae-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.2
    • /
    • pp.108-117
    • /
    • 2011
  • In drafting the standards on changes in current conditions, the height or the number of stories is applied in a restrictive manner by limiting to securing the distance to vertical surface for cultural properties within the influence investigation area, but this is expected to have a negative impact on the surrounding sceneries as well as results in the dwarfing phenomenon for precious cultural properties. That is, the preparation for supplementing the insufficient objectivity that is likely to take place during the process of drafting the standards on changes in current conditions. Thus the author attempts to suggest the analytic method for the decision making related to objective and reasonable determination and regulation of the changes in current conditions through computer based simulation work that considers the cultural properties and surrounding environments under investigation. In order to achieve such research objectives, the author reviewed the subject sites where the cultural property dwarfing phenomenon was expected to occur in case of the permission for the changes in current conditions or where the impact of natural landscape and natural feature on the earth is less than architectural building or artificial structure or where the new policy program is likely to be adopted due to incomplete establishment of current condition change standard within influence investigation area, among other cultural properties with architectural building or artificial structure nearby located in Cheonan city and then selected Cheonansaji Dangganjiju(flag poles) and Jiksanhyun Gwana(government office). The author then undertook the quantitative visibility analysis in order to determine the comprehensive prospect rights for the cultural properties and surrounding environments concerned.

A Study on the Deduction of Domestic BIPV Definition Revision Plan through Expert Delphi Survey (전문가 델파이 조사를 통한 국내 BIPV 정의 개정 방안 도출에 관한 연구)

  • Park, Seung-Joon;Oh, Choong-Hyun
    • Journal of Digital Convergence
    • /
    • v.19 no.10
    • /
    • pp.75-86
    • /
    • 2021
  • Recently, the domestic BIPV market is expected to revitalize with the introduction of the "zero-energy building certification system(2020~)", but it is somewhat stagnant due to the rigidity of definitions in the current domestic BIPV construction standards. Also, since there is delaying revision on definition and standardization of BIPV, the system is so weak that there are cases where it has been approved as BIPV simply by installing a structure on the wall and fixing the module roughly. The damage caused by this can be passed on to consumers, and it can only create a negative perception of BIPV and jeopardize the entire market. The BIPV definition was prepared through a Delphi survey of related experts about market stagnant cause, unreasonable regulation, etc, and a revised plan was derived accordingly.

Extraction of Road Structure Elements for Developing IFC(Industry Foundation Classes) Model for Road (도로분야 IFC 확장을 위한 도로시설의 구성요소 도출)

  • Moon, Hyoun-Seok;Choi, Won-Sik;Kang, Leen-Seok;Nah, Hei-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1195-1203
    • /
    • 2014
  • Since IFC (Industry Foundation Classes) 4 is based on the representation of 3D elements for an architecture project, and does not define standardized shapes for civil projects such as roads, bridges, and tunnels etc, it has limitations in securing interoperability for exchanging a shape information model for the civil projects. Besides, since road facilities have a linear reference, which is modeled along the center alignment, it is difficult the designers to create a standardized 3D road model. The aim of this study is to configure structure elements and their attribute for a road in the perspective of 3D design for developing a shape information model for the road. To solve these issues, this study analyzes the design documents, which consist of a road design handbook, guide, specifications and standards, and then extract shape elements and their attributes of road structures. Such shape elements are defined as an entity item and we review a hierarchical structure of a road shape defined by a virtual road model. The detailed elements and their attributes can be utilized as a 3D shape information model for constructing BIM (Building Information Modeling) environment for Infrastructures. Besides, it is expected that the suggested items will be utilized as a base data for extending to IFC for a road subdividing the detailed shapes, types and attributes for road projects.

A Study on Seismic Performance of External Reinforcement for Unreinforced Masonry Buildings (비보강 조적조 건축물의 외부 보강에 따른 내진성능 연구)

  • Jong-Yeon Kim;Jong Kang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.43-52
    • /
    • 2024
  • In this study, we evaluated the seismic performance of a masonry building that was not designed to be earthquake-resistant and attempted to improve the seismic performance by adopting a seismic reinforcement method on the exterior of the building. In addition, the building seismic design standards and commentary(KDS 41 17 00:2019) and existing facility(building) seismic performance evaluation methods were applied to evaluate seismic performance, and a pushover analysis was performed using non-linear static analysis. As the result of this study, it was determined that seismic reinforcement was urgent because the distribution rate of earthquake-resistant design of houses in Korea was low and masonry structures accounted for a large proportion of houses. When reinforcing the steel beam-column+brace frame in a masonry building, the story drift angle was 0.043% in the X direction and 0.047% in the Y direction, indicating that it satisfied the regulations. The gravity load resistance capacity by performance level was judged to be a safe building because it was habitable in both X and Y directions. In conclusion, it is believed that the livability and convenience of the house can be secured by reinforcing the exterior of the building and the seismic performance and behavior of the structure can be clearly predicted.

Appropriateness Evaluation of Train Vibration Evaluation Method Considering Vibration Levels of Retaining Wall Adjacent to Railway Tunnels (철도터널과 인접한 흙막이 가시설의 진동 수준을 고려한 열차진동 평가방법의 적정성 평가)

  • Donghee Woo;Yeongjin Lee;Yongjae Song;Kangil Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.10
    • /
    • pp.5-13
    • /
    • 2023
  • With the recent increase in development projects centered on urban areas, the construction of building structures is increasing in areas adjacent to the urban railway operation section. In this case, since ground vibration is generated by the train in operation and affects the adjacent structure, the building structure needs appropriate vibration reduction against train vibration generated at the adjacent location from the desing phase. However, the vibration levels calculated vary depending on the train vibration evaluation method, which means that the implementation of vibration reduction may vary depending on the train vibration evaluation method. Therefore, this study calculated the vibration level according to ground conditions, tunnel depth and separation distance between vibration sources and adjacent structures using numerical analysis and train vibration evaluation methods, and compared them to designning phase. And the appropriate separation distance between the tunnel and the adjacent structure was evaluated by comparing the vibration level with the allowable standards. As a result of the study, the Ungar and Bender evaluation method is evaluated as the most appropriate among the train vibration evaluation methods, and the appropriate separation distance between the tunnel and the adjacent structure is evaluated to be more than 4.5D.

The Comparison of Apartment Management System Between Korea and Japan (한국과 일본의 공동주택 관리제도 비교)

  • Kang, Hye-Kyoung
    • Journal of Family Resource Management and Policy Review
    • /
    • v.10 no.3
    • /
    • pp.45-62
    • /
    • 2006
  • This research is carried out to inspect the Apartment Management System of Japan, to examine the similarities and differences between the Korean Apartment Management System and the Japanese Apartment Management System. First, as the basis law of apartment management, there exists the Building Unit Ownership Act, the Promotion Law fur Adequate Mansion Management of Japan, the Housing Law, Housing Execution Law and Rule of Korea. Second, the Association of Apartment Owners, an organization of owners of apartments in Japan and the Commission of the Representatives of the Occupants in Korea become the subject of maintenance. The Japan structure is made of the Assembly, the Director and the President. The Korean structure is made of Regular and Temporary Conferences and elected Officers(1 president, at least 2 directors and at least 1 inspector). The Commission of the Representatives of the Occupants and the Organization of Owners of Apartments make bylaws and diverse maintenance rules. Third, the foremost reason why the Korean structure of maintenance of apartments is less efficient than Japan is because of the small number of people dispatched to the living-environment maintenance team and their short terms. It is necessary to grow professionals related to this sector and to have enough public servants that specialize in this. Fourth, although it is compulsory to make long term plans for maintenance based on the Housing Law, because the reserve fund is decided by the maintenance rule(with no compulsory standards of reservation) of each apartment, it is difficult to reserve an adequate amount of reserve fund. So as in the example of the state of Hawaii in America, based on long term plans for maintenance, an execution rule of the Housing Law should be made which enforces to reserve at least 50 percent of future maintenance expenses.

  • PDF

A Study on the Development of a Head for Prevent the Fire Spread of Exterior (외장재 연소확대방지용 헤드 개발에 관한 연구)

  • Min, Se-Hong;Kim, Mi-Suk;Jang, Young-Jin;Sa, Jae-Chun;Bae, Yeon-Jun;Lee, Jae-Moon
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.113-119
    • /
    • 2012
  • In this research, in order to prevent spread of vertical flame from building exterior fire, A head was developed. The performance standards of Head development complied with NFPA 80A 7.7.4.3 (Recommended Practice for Protection of Buildings Exterior Fire Exposures) and the standards are applied to the discharge pressure was 0.05 MPa and the discharge flow rate was 60 l/min. The head was developed about applied to 0.05 MPa and 65 l/min through the process of the experiment of five times, it is processed from drencher head and used in domestic intended use and structure are quite different. An appropriate distances between the head and the head proved as the experimental results to within 3 m~5 m and it selectively applied to the design is being considered depending on the fire hazard strength.