• 제목/요약/키워드: Building Response

검색결과 1,907건 처리시간 0.027초

벽식 APT의 반응수정계수 추정에 관한 연구 (Evaluation of Response Modification Factors for Shear Wall Apartment Building)

  • 송정원;송진규;이수곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.859-864
    • /
    • 2001
  • For earthquake resistance design, a response modification factor is used to reduce the design strength and it reflects ductility, reserve strength, redundancy and damping effect. But this factor has not theoretical basis. In this study, two response modification factors are compared and analyzed for shear wall apartment building.; the one is introduced by ATC-19 Procedures, the other is suggested FEMA-273 and ATC-40 through nonlinear static analysis. For the results, ATC-19 procedure gives a reasonable estimation to R factor. But $R_{u}$ by using FEAM-273 and ATC-40 methods is estimated so small in case of a minor or moderate earthquake region. Due to this fact, response modification factor is smaller than suggested load criterion 3.0. So, it needs to decrease wall volume and reduce the global strength and system stiffness for proper ductile behavior matching to domestic load criterion.

  • PDF

점탄성물질 난류댐퍼를 이용한 V형 철골 브레이스 골조의 진동응답해석 (A Vibration Response Analysis of Steel Building Frame with V Shape Brace Vibrationally Controlled by Turbulent Flow Dampers Sealed by Visco-Elastic Material)

  • 이호;이상엽
    • 한국공간구조학회논문집
    • /
    • 제2권3호
    • /
    • pp.103-113
    • /
    • 2002
  • This thesis investigates vibration response characteristics of building frames in which dampers are installed. The frames belong to passively vibration-controlled. Structures which utilizes energy dissipation of mechanical dampers provided in the structure. In this thesis, a turbulent flow damper sealed by visco-elastic material was dealt with as the device of passive vibration control. To investigate the resisting force characteristics of the damper, harmonic vibratration tests were carried out. Based on the test results, a theoretical model of the damper resistance was presented and a method of identifying the model parameters was proposed. Shaking table tests of the frame with and without the dampers were carried out and the effectiveness of the damper was examined. The response of the frame with the dampers was reduced to 1/2 or 1/3 of the cases without the damper.

  • PDF

반응표면분석법을 이용한 가압성형 보드의 최적 배합비 산정 (Optimization of Mixing Proportion of Press-forming Board by Response Surface Methodology)

  • 이준철;김진성;이보경;최형길
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.182-183
    • /
    • 2019
  • In this study, the optimization of mixing proportion of press-forming board with blast furnace slag, pearlite and bottom ash was investigated using the response surface methodology. Ten Mixing proportions of specimens were designed by the response surface design, and then flexural failure load, moisture content and water absorption of specimens were measured. As a result of the reaction surface analysis based on the experimental results, it was possible to derive the optimal mixing proportion with the satisfaction of 93%.

  • PDF

Seismic energy dissipation in torsionally responding building systems

  • Correnza, J.C.;Hutchinson, G.L.;Chandler, A.M.
    • Structural Engineering and Mechanics
    • /
    • 제3권3호
    • /
    • pp.255-272
    • /
    • 1995
  • The paper considers aspects of the energy dissipation response of selected realistic forms of torsionally balanced and torsionally unbalanced building systems, responding to an ensemble of strong-motion earthquake records. Focus is placed on the proportion of the input seismic energy which is dissipated hysteretically, and the distribution of this energy amongst the various lateral load-resisting structural elements. Systems considered comprise those in which torsional effects are discounted in the design, and systems designed for torsion by typical code-defined procedures as incorporated in the New Zealand seismic standard. It is concluded that torsional response has a fundamentally significant influence on the energy dissipation demand of the critical edge elements, and that therefore the allocation of appropriate levels of yielding strength to these elements is a paramount design consideration. Finally, it is suggested that energy-based response parameters be developed in order to assist evaluations of the effectiveness of code torsional provisions in controlling damage to key structural elements in severe earthquakes.

실시간 IoT 정보 활용 피난시스템의 피난성능 연구 (A Study on the Evacuation Performance of Evacuation System using Real-time IoT Information)

  • 이철규;문상호;이상규;이계은
    • 한국멀티미디어학회논문지
    • /
    • 제22권2호
    • /
    • pp.281-291
    • /
    • 2019
  • In order to reflect complex and diverse building types, resident characteristics and disaster factors, it is necessary to introduce a flexible situation-based response system based on real-time information. Intelligent CCTV, hybrid sensor, location scanner, and customized broadcasting device were examined to introduce for the real-time response intelligent response system and its feasibility was verified through field test. In addition, based on the real-time information, the evacuation simulation was executed by assuming the dormitory building and the resident of the school, and the safety of the evacuation and the shortening of the pinnacle time were confirmed. The feasibility of real time information based evacuation comparing with the existing evacuation system were verified in the case of evacuation.

Dynamic Analysis of AP1000 Shield Building Considering Fluid and Structure Interaction Effects

  • Xu, Qiang;Chen, Jianyun;Zhang, Chaobi;Li, Jing;Zhao, Chunfeng
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.246-258
    • /
    • 2016
  • The shield building of AP1000 was designed to protect the steel containment vessel of the nuclear reactor. Therefore, the safety and integrity must be ensured during the plant life in any conditions such as an earthquake. The aim of this paper is to study the effect of water in the water tank on the response of the AP1000 shield building when subjected to three-dimensional seismic ground acceleration. The smoothed particle hydrodynamics method (SPH) and finite element method (FEM) coupling method is used to numerically simulate the fluid and structure interaction (FSI) between water in the water tank and the AP1000 shield building. Then the grid convergence of FEM and SPH for the AP1000 shield building is analyzed. Next the modal analysis of the AP1000 shield building with various water levels (WLs) in the water tank is taken. Meanwhile, the pressure due to sloshing and oscillation of the water in the gravity drain water tank is studied. The influences of the height of water in the water tank on the time history of acceleration of the AP1000 shield building are discussed, as well as the distributions of amplification, acceleration, displacement, and stresses of the AP1000 shield building. Research on the relationship between the WLs in the water tank and the response spectrums of the structure are also taken. The results show that the high WL in the water tank can limit the vibration of the AP1000 shield building and can more efficiently dissipate the kinetic energy of the AP1000 shield building by fluid-structure interaction.

A review of the philippine green building rating system, BERDE in comparison with G-SEED and LEED

  • Culiao, Rudiliza;Tae, Sungho;Kim, Rakhyun
    • The International Journal of Sustainable Building Technology and Urban Development
    • /
    • 제9권2호
    • /
    • pp.87-94
    • /
    • 2018
  • Different countries create their own green building rating system to be in line with sustainable development as a response to the urgent call for solution for Climate Change and degradation of the environment due to rapid population growth and economic development. This study conducts a critical review on the Philippine national voluntary green building rating system, BERDE, in comparison with South Korea's national voluntary green building rating system, G-SEED and U.S. rating system LEED. Their categories, building types assessed, and assessment methods were compared side by side to seek better practice(s) for green building rating assessment for Philippine green building projects.

Explosive loading of multi storey RC buildings: Dynamic response and progressive collapse

  • Weerheijm, J.;Mediavilla, J.;van Doormaal, J.C.A.M.
    • Structural Engineering and Mechanics
    • /
    • 제32권2호
    • /
    • pp.193-212
    • /
    • 2009
  • The resilience of a city confronted with a terrorist bomb attack is the background of the paper. The resilience strongly depends on vital infrastructure and the physical protection of people. The protection buildings provide in case of an external explosion is one of the important elements in safety assessment. Besides the aspect of protection, buildings facilitate and enable many functions, e.g., offices, data storage, -handling and -transfer, energy supply, banks, shopping malls etc. When a building is damaged, the loss of functions is directly related to the location, amount of damage and the damage level. At TNO Defence, Security and Safety methods are developed to quantify the resilience of city infrastructure systems (Weerheijm et al. 2007b). In this framework, the dynamic response, damage levels and residual bearing capacity of multi-storey RC buildings is studied. The current paper addresses the aspects of dynamic response and progressive collapse, as well as the proposed method to relate the structural damage to a volume-damage parameter, which can be linked to the loss of functionality. After a general introduction to the research programme and progressive collapse, the study of the dynamic response and damage due to blast loading for a single RC element is described. Shock tube experiments on plates are used as a reference to study the possibilities of engineering methods and an explicit finite element code to quantify the response and residual bearing capacity. Next the dynamic response and progressive collapse of a multi storey RC building is studied numerically, using a number of models. Conclusions are drawn on the ability to predict initial blast damage and progressive collapse. Finally the link between the structural damage of a building and its loss of functionality is described, which is essential input for the envisaged method to quantify the resilience of city infrastructure.

지반굴착 유발 진행성 지반변위에 의한 인접구조물의 거동분석 (Response Analysis of Nearby Structures to Excavation-Induced Advancing Ground Movements)

  • 손무락
    • 대한토목학회논문집
    • /
    • 제29권4C호
    • /
    • pp.153-162
    • /
    • 2009
  • 본 논문은 지반굴착으로 인해 발생된 인접지반에서의 진행성 지반변위가 구조물에 미치는 영향을 구조물 및 지반의 특성을 달리하면서 지반-구조물 상호작용이 고려된 상태에서 조사한 것이다. 지반굴착에 의해 발생된 진행성 지반변위에 노출된 4층 및 2층의 블록식구조물이 서로 다른 조건의 지반위에 위치할 때 발생되는 구조물 거동이 수치해석을 통해 조사된다. 수치해석을 위한 구조물은 소요전단 및 인장강도 이상의 응력이 발생할 때 구조물에 크랙이 발생될 수 있도록 모델링되었다. 굴착유발 진행성 지반변위에 노출된 4층 및 2층의 블록식구조물의 거동은 지반변위의 진행단계에 따라 조사되며, 이로부터 얻어진 거동특성은 구조물이 지반굴착의 최종단계에서 일어나는 지반변위에 일시에 노출될 때 발생하는 구조물의 거동특성과도 비교된다. 서로 다른 구조물 특성 및 지반조건을 가진 구조물이 진행성 지반변위 및 최종 지반변위에 노출될 때 발생하는 거동비교는 구조물에 발생한 크랙의 분포정도 및 변형크기를 고려하면서 조사되며, 이러한 비교로부터 얻어진 결과는 지반굴착으로 인해 유발되는 인접구조물의 손상을 제어하고 최소화하는데 필요한 정보를 제공한다.

지진파 탁월주기를 고려한 비구조요소의 수평설계지진력 평가 (A Study on Evaluation of Horizontal Force of Non-structural Components Considering Predominant Periods of Seismic Waves)

  • 오상훈;김주찬
    • 한국지진공학회논문집
    • /
    • 제24권6호
    • /
    • pp.267-275
    • /
    • 2020
  • In the event of an earthquake, non-structural components require seismic performance to ensure evacuation routes and to protect lives from falling non-structural components. Accordingly, the seismic design code proposes horizontal force for the design and evaluation of non-structural components. Ground motion observed on each floor is affected by a building's eigen vibration mode. Therefore, the earthquake damage of non-structural components is determined by the characteristics of the non-structural component system and the vibration characteristics of the building. Floor response spectra in the seismic design code are estimated through time history analysis using seismic waves. However, it is difficult to use floor response spectra as a design criterion because of user-specific uncertainties of time history analysis. In addition, considering the response characteristics of high-rise buildings to long-period ground motions, the safety factor of the proposed horizontal force may be low. Therefore, this study carried out the horizontal force review proposed in the seismic design code through dynamic analysis and evaluated the floor response of seismic waves considering buildings and predominant periods of seismic waves.