• 제목/요약/키워드: Building Integrated Photovoltaic-BIPV

검색결과 127건 처리시간 0.028초

천공상태에 따른 박막 BIPV 창호의 온도 및 발전특성 실측연구 (A Study on Optimum of Performance Objectives of Passive House with Load Reduction elements)

  • 김빛나;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.171-176
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temporature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish mornitoring system and analysis the date from the mornitoring system to evaluate the performance of PV windows that has thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

  • PDF

건물일체형 투명 모듈의 온도 변화에 따른 발전 특성 (Generation characteristics of transparent BIPV module according to temperature change)

  • 박경은;강기환;김현일;유권종;장대호;이문희;김준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF

비정질 박막 투과형 태양전지모듈의 온도특성에 따른 발전성능 평가 연구 (A Study on the Evaluation of Power Performance according to Temperature Characteristics of Amorphous Transparent Thin-Film)

  • 안영섭;송종화;이성진;윤종호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2009
  • This study evaluated the influence of temperature on the PV module surface on power output characteristics, especially for an amorphous transparent thin-film PV module which was applied to a full-scale mock-up model as building integrated photovoltaic system. The tested mock-up consisted of various slopes of PV module, facing to the south. The annual average temperature of the module installed with the slope of $30^{\circ}$ revealed $43.1^{\circ}C$, resulting in $7^{\circ}C$ higher than that measured in PV modules with the slope of $0^{\circ}$and $90^{\circ}$ did. This $30^{\circ}$ inclined PV module also showed the highest power output of 28.5W (measured at 2 PM) than other two modules having the power output of 20.4W and 14.9W in the same time for $0^{\circ}$ and $90^{\circ}$ in the slope, respectively. In case of the $30^{\circ}$ inclined PV module, it exhibited very uniform distribution of power output generation even under the higher temperature on the module surface. Consequently, the surface temperature of the PV module analyzed in this study resulted in 0.22% reduction in power output in every $1^{\circ}C$ increase of the module surface temperature.

  • PDF

플러스에너지하우스 설계 및 에너지 성능 평가 (Design and Energy Performance Evaluation of Plus Energy House)

  • 김민휘;임희원;신우철;김효중;김현기;김종규
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.55-66
    • /
    • 2018
  • South Korea aims to shift the 20 percent of electricity supplement from the fossil fuel including the nuclear to renewable energy systems by 2030. In order to realize this agenda in the buildings, the plus energy house is necessary to increase the renewable energy supplement beyond the zero energy house. This paper suggested KePSH (KIER Energy-Plus Solar House) and energy performance of house and renewable energy systems was investigated. The KePSH has the target of generating 40% surplus energy than the conventional house energy consumption. The plus energy house is the house that generates surplus energy from the renewable energy sources than that consumes. In order to minimize the cooling and heating load of the house, the shape design and passive parameters design were conducted. Based on the experimental data of the plug load in the typical house, the total energy consumption of the house was estimated. This paper also suggested renewable energy sources integrated HVAC system using air-source heat pump system. Two cases of renewable energy system integration methods were suggested, and energy performance of the cases was investigated using TRNSYS 17 program. The results showed that the BIPV (building integrated photovoltaic) system (i.e., CASE 1) and BIPV and BIST system (i.e., CASE 2) shows 42% and 29% of plus energy rate, respectivey. Also, CASE 1 can generate 59% more surplus energy compared with the CASE 2 under the same installation area.

에너지시설에 관한 친환경 메시지 디자인이 대학생의 태도에 미치는 영향 (The Effects of Message Design Related to Photovoltaic Energy on University Students' Attitude)

  • 서은정;김태연;류재명
    • 한국환경교육학회지:환경교육
    • /
    • 제25권2호
    • /
    • pp.242-253
    • /
    • 2012
  • This research aims to identify the effect of message design on university students' attitude toward the BIPV (Building Integrated Photovoltaic) and find out its educational availability and implications in environment education. For this purpose, we conducted a survey on questionnaires answered by 244 students of S university at lunch time in the school restaurant with the imaginary scenario that it is required to increase the food price due to photovoltaic-equipment. The students were divided into 9 groups and according to whether the eco-friendly message components are offered and the different rate of a rise in the foods' price. In order to look over various aspects of attitudes, the questionnaires are subdivided into 2 parts according to the classification of attitudes; the preference as an cognitive-affective attitude and the intention of visit as an behavioral attitudes. The results of this study are summarized as follows; (1) The eco-friendly message design has a significant effect on students' attitude. (2) If given explanation including information regarding eco-friendly facility and marking eco-friendly' adject, it has an positive influence on students' preference and intention of visit. (3) It is more effective to offer the information about the reason why the cost increase than just explain the eco-friendly characteristics of object as the message design strategy to attract student's positive attitude. (4) Although it is required to burden a certain scale of cost, students show higher preference and intention of visit if given the eco-friendly message design.

  • PDF

태양전지 모듈의 구성 요소가 PID 발생에 미치는 영향 (The Effect of PID Generation by Components of the PV Module)

  • 김한별;정태희;강기환;장효식
    • 한국전기전자재료학회논문지
    • /
    • 제26권10호
    • /
    • pp.760-765
    • /
    • 2013
  • PID (potential induced degradation) of PV module is the degradation of module due to the high potential difference between the front surface of solar cells and ground when PV modules operate under high humidity and temperature conditions. PID is generally derived from the positive sodium ions in front glass that are accumulated on P-type solar cells. Therefore, some papers for the electrical characteristic of only front components as glass, EVA sheet, solar cell under PID generation condition were revealed. In this paper, we analyzed the different outputs of module with PID by considering the all parts of module including the back side elements such as glass, back sheet. Mini modules with one solar cell were fabricated with the various parts on front and back sided of module. To generate PID of module in a short time, the all modules were applied.1,000 V in $85^{\circ}C$, 85% RH. The outputs, dark IV curves and EL images of all modules before and after experiments were also measured to confirm the main components of module for PID generation. From the measured results, the outputs of all modules with front glass were remarkably reduced and the performances of modules with back and front glass were greatly deteriorated. We suggest that the obtained data could be used to reduce the PID phenomenon of diverse modules such as conventional module and BIPV (building integrated photovoltaic) module.

염료감응형 태양전지를 적용한 유리 패널의 효율 향상에 관한 연구 (A Study on the Efficiency Improvement of Glazing Panel with DSC Modules)

  • 장한빈;강준구;이상길;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.35-41
    • /
    • 2013
  • Dye-sensitized solar cell (DSC) allows light transmission and the application of various colors that make it especially suitable for building-integrated PV (BIPV) application. In order to apply DSC module into windows, it has to be panelized: DSC module should be protected with reinforced glass to the entire surface. Up to date, it seems to be common to make double glazing with DSC modules with air gaps between the glasses and the DSC modules. Few research has been conducted on the characteristics of various glazing types with DSC modules. This study aims to analyze the electrical performance of DSC modules according to panelizing method for glazing unit with DSC modules. The prototype of the DSC glazing that applied silicone filler between DSC modules and glasses was developed. The electrical performances of this type of DSC glazing with the filler and rather conventional double glazing with DSC modules were compared. Their performances were measured using a solar simulator that is suitable for DSC performance testing. The results indicated that the electrical performance of the filler type DSC glazing improved by 7% compared to that of the conventional DSC double glazing type.

국내외 철도 시스템의 신재생에너지 적용현황 (Applications of Renewable Energy for Railway System)

  • 박한얼;김덕현;김대년
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.135.1-135.1
    • /
    • 2011
  • 철도 선진국을 중심으로 신재생에너지의 철도 시스템 적용이 가속화 되고 있고, 국내에서도 철도 시스템에 신재생에너지를 적용하려는 시도가 이루어지고 있다. 이미 상당수의 신규 역사가 BIPV(building integrated photovoltaic) 시스템을 적용하고 있고, 단순히 유휴지를 이용한 풍력 발전 시스템을 넘어서 차량의 주행풍을 이용하거나 차량 외부에 풍력 발전기를 설치하는 등의 다양한 시도들이 이루어지고 있다. 수소 에너지를 연료로 하는 연로전지의 경우 기존 전기철도의 대체 연료로서 주목을 받으며 많은 연구가 이루어졌고 현재는 시험 운전 단계에 이르러 있다. 지열의 경우에는 벌써 오래전부터 승강장 또는 선로의 해빙장치의 에너지원으로 사용 되고 있다. 이밖에 수력 및 해양 에너지의 경우 전철전력의 청정 에너지 공급원으로 보고되고 있으며, 차량이나 역사 내에서 발생하는 운동 에너지를 수확하여 전기 에너지로 변환하는 에너지 하베스팅 기술이 새로운 신재생에너지 기술로서 많은 관심을 받고 있다. 에너지 문제와 온실가스 감축 의무 부담이 날로 가중되는 현 시점에서 신재생에너지의 전기철도 시스템 적용은 이 같은 문제를 해결할 수 있는 확실한 대안이 될 것이다. 본 논문에서는 국내외 전기철도 시스템의 신재생에너지 적용 기술과 적용 방안에 대해 고찰한다.

  • PDF

건물일체형 태양광발전시스템(BIPV) 적용을 위한 태양전지모듈 제조 (PV module manufacture for application of Building Integrated photovoltaic system)

  • 김기환;유권종;한득영;안형근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1465-1467
    • /
    • 2004
  • In this paper, deduced manufacturing condition of glass/glass curtain wall module and metal curtain wall module. From the results. lamination condition of glass/glass curtain wall module deduced optimum in pumping $time-120^{\circ}C$ 23min, slow $press-120^{\circ}C$. 300mmHg. 3min. standard $press-120^{\circ}C$. 200mmHg. 0.5min. fast $press-120^{\circ}C$. 100mmHg. 0.3min and $curing-140^{\circ}C$, 6min, and lamination condition of metal curtain wall module deduced optimum in pumping $time-120^{\circ}C$. 8min, slow $press-120^{\circ}C$, 700mmHg. 0.5min, standard $press-120^{\circ}C$, 600mmHg, 0.5min. fast $press-120^{\circ}C$, 100mmHg. 1.5min and $curing-140^{\circ}C$. 6min. This time. power uniformity of glass/glass curtain wall module and metal curtain wall module showed each ${\pm}2.7\%,\;{\pm}2.12\%$.

  • PDF

커튼월 스팬드럴 적용을 위한 CIGS 박막 모듈의 특성 분석 연구 (The Characteristics on CIGS Thin Film PV Module for Curtain Wall Spandrel Applications)

  • 강준구;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.107-113
    • /
    • 2013
  • In this study, three different types of experimental models of BIPV curtain wall units with GIGS modules were built, and their thermal and electrical performances were analyzed. The experimental results showed that the temperature of the rear side of the GIGS module with the application of an insulation in the curtain wall spandrels was higher than a GIGS module standalone by $22^{\circ}C$, which results in a reduction in the power generation of the former by 8 %. On the other hand, when ventilation was applied to the model to improve the power generation performance, the module temperature was observed to be $142^{\circ}C$ lower compared to the enclosed type, and the power generation performance improved by 5 %. It confirmed that the temperature increase in the rear side of the GIGS module with insulation layer reduced the electrical performance of the module. Based on this, it is claimed that providing sufficient ventilation at the GIGS applied spandrels contribute to improve the power generation of the GIGS module.