• Title/Summary/Keyword: Building History

Search Result 1,350, Processing Time 0.024 seconds

The Birth and Development of High-Rise Buildings in Japan: Focusing on the Historical Development of Height and Floor Area Ratio Regulations

  • Akihiko Osawa
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.195-201
    • /
    • 2023
  • This paper reviews the history of the birth and development of the skyscraper in Japan, mainly from the perspective of the legal system, and presents the following points: 1) After 1919, building height was limited to 31 m or less, which continued after the war and defined the skyline of Japan's major cities; 2) The 31-meter height limit became a problem during rapid economic growth. With the development of tall building construction technology, the height limit was eliminated, and skyscrapers were born in Japan in the 1960s; 3) Later, the number of skyscrapers increased more rapidly in the post-bubble period after the collapse of the bubble economy in the 2000s than in the boom years of the 1980s, when the floor-area ratio was relaxed for economic uplift and urban renewal. The number of skyscrapers increased rapidly against the backdrop of the deregulation of the floor-area ratio.

Elasto-plastic time history analysis of a 117-story high structure

  • Wu, Xiaohan;Li, Yimiao;Zhang, Yunlei
    • Computers and Concrete
    • /
    • v.19 no.1
    • /
    • pp.7-17
    • /
    • 2017
  • In Chinese Design Codes, for super high-rise buildings with complex structural distribution, which are regarded as code-exceeding buildings, elasto-plastic time history analysis is needed to validate the requirement of "no collapse under rare earthquake". In this paper, a 117-story super high-rise building is discussed. It has a height of 597 m and a height-width ratio of 9.5, which have both exceeded the limitations stipulated by the Chinese Design Codes. Mega columns adopted in this structure have cross section area of about $45m^2$ at the bottom, which is infrequent in practical projects. NosaCAD and Perform-3D, both widely used in nonlinear analyses, were chosen in this study, with which two model were established and analyzed, respectively. Elasto-plastic time history analysis was conducted to look into its seismic behavior, emphasizing on the stress state and deformation abilities under intensive seismic excitation.From the comparisons on the results under rare earthquake obtained from NosaCAD and Perform-3D, the overall responses such as roof displacement, inter story drift, base shear and damage pattern of the whole structure from each software show agreement to an extent. Besides, the deformation of the structure is below the limitation of the Chinese Codes, the time sequence and distribution of damages on core tubes are reasonable, and can dissipate certain inputted energy, which indicates that the structure can meet the requirement of "no collapse under rare earthquake".

Sick Building Syndrome and the Related Factors in Office Workers (일부 대형빌딩 근무자에서 sick building syndrome의 위험요인에 관한 연구)

  • Baik, Jae-Joong;Cho, Soo-Hun;Park, Byung-Joo;Kang, Dae-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.157-170
    • /
    • 1997
  • A cross-sectional study was conducted to investigate the prevalence and risk factors for symptoms associated with sick building syndrome in four office buildings located in Seoul. Information on personal factors, job-related factors, and medical history were collected using self-administered questionnaires modified from the National Institute for Occupational Safety and Health Indoor Air Quality questionnaire in 321 office workers in these buildings. The prevalence of general and irritant symptom groups was higher than the prevalence of dermatologic and respiratory symptom groups. Daily total work time, work time in the office, and work time with video display terminals (VDT) were identified as the risk factors for symptom groups associated with sick building syndrome by multiple linear logistic regression analysis. In conclusion, these results indicated that the symptom prevalence in this study is similar with the results reported from previous studies conducted in other countries and work time and work with VDT are related to sick building syndrome in Korea.

  • PDF

Assessment of pushover-based method to a building with bidirectional setback

  • Fujii, Kenji
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.421-443
    • /
    • 2016
  • When conducting seismic assessment of an asymmetric building, it is essential to carry out three-dimensional analysis considering all the possible directions of seismic input. For this purpose, the author proposed a simplified procedure is to predict the largest peak seismic response of an asymmetric building subjected to horizontal bidirectional ground motion acting in an arbitrary angle of incidence in previous study. This simplified procedure has been applied to torsionally stiff (TS) asymmetric buildings with regular elevation. However, the suitability of this procedure to estimate the peak response of an asymmetric building with vertical irregularity, such as an asymmetric building with setback, has not been assessed. In this article, the pushover-based simplified procedure is applied to estimate the peak response of asymmetric buildings with bidirectional setback. Nonlinear dynamic (time-history) analysis of two six-storey asymmetric buildings with bidirectional setback and designed according to strong-column weak beam concept is carried out considering various directions of seismic input, and the results compared with those estimated by the proposed method. The largest peak displacement estimated by the simplified method agrees well with the envelope of the dynamic analysis response. The suitability assessment of the simplified procedure to analysed building models is made as well based on pushover analysis results.

Evaluation of Response Modification Factor of Steel Special Resisting Frame Building Before and After Retrofitted with Buckling Restrained Brace (비좌굴가새의 보강 전과 후의 철골 특수모멘트저항골조 건물의 R계수 평가)

  • Shin, Jiuk;Lee, Kihak;Jo, Yeong Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.11-19
    • /
    • 2013
  • This research presents that seismic performance of steel moment resisting frame building designed by past provision(UBC, Uniform Building Code) before and after retrofitted with BRB (Buckling-Restrained Brace) was evaluated using response modification factor (R-factor). In addition, the seismic performance of the retrofitted past building was compared with that specified in current provision. The past building considered two different connections: bilinear connection, which was used by structural engineer for building design, and brittle connection observed in past earthquakes. The nonlinear pushover analysis and time history analysis were performed for the analytical models considered in this study. The R-factor was calculated based on the analytical results. When comparing the R-factor of the current provision with the calculated R-factor, the results were different due to the hysteresis characteristics of the connection types. After retrofitted with BRBs, the past buildings with the bilinear connection were satisfied with the seismic performance of the current provision. However, the past buildings with the brittle connection was significantly different with the R-factor of the current provision.

Post-earthquake building safety evaluation using consumer-grade surveillance cameras

  • Hsu, Ting Y.;Pham, Quang V.;Chao, Wei C.;Yang, Yuan S.
    • Smart Structures and Systems
    • /
    • v.25 no.5
    • /
    • pp.531-541
    • /
    • 2020
  • This paper demonstrates the possibility of evaluating the safety of a building right after an earthquake using consumer-grade surveillance cameras installed in the building. Two cameras are used in each story to extract the time history of interstory drift during the earthquake based on camera calibration, stereo triangulation, and image template matching techniques. The interstory drift of several markers on the rigid floor are used to estimate the motion of the geometric center using the least square approach, then the horizontal interstory drift of any location on the floor can be estimated. A shaking table collapse test of a steel building was conducted to verify the proposed approach. The results indicate that the accuracy of the interstory drift measured by the cameras is high enough to estimate the damage state of the building based on the fragility curve of the interstory drift ratio. On the other hand, the interstory drift measured by an accelerometer tends to underestimate the damage state when residual interstory drift occurs because the low frequency content of the displacement signal is eliminated when high-pass filtering is employed for baseline correction.

Fragility Assessment of Damaged Piloti-Type RC Building With/Without BRB Under Successive Earthquakes (연속 지진에 의하여 손상된 필로티 RC 건축물의 BRB 보강 전/후의 취약성 평가)

  • Shin, Jiuk;Kim, JunHee;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.133-141
    • /
    • 2013
  • This paper presents the seismic evaluation and prediction of a damaged piloti-type Reinforced Concrete (RC) building before and after post-retrofitting under successive earthquakes. For considering realistic successive earthquakes, the past records measured at the same station were combined. In this study, the damaged RC building due to the first earthquake was retrofitted with a buckling-restrained brace (BRB) before the second earthquake occurred. Nonlinear Time History Analysis (NTHA) was performed under the scaled intensity of the successive ground motions. Based on the extensive structural response data obtained form from the NTHA, the fragility relationships between the ground shaking intensity and the probability of reaching a pre-determined limit state was were derived. In addition, The the fragility curves of the pre-damaged building without and with the BRBs were employed to evaluate the effect of the successive earthquakes and the post-retrofit effect. Through the seismic assessment subjected to the successive records, it was observed that the seismic performance of the pre-damaged building was significantly affected by the severity of the damage from the first earthquake damages and the hysteresis behavior of the retrofit element.

Seismic fragility analysis of base isolation reinforced concrete structure building considering performance - a case study for Indonesia

  • Faiz Sulthan;Matsutaro Seki
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.3
    • /
    • pp.243-260
    • /
    • 2023
  • Indonesia has had seismic codes for earthquake-resistant structures designs since 1970 and has been updated five times to the latest in 2019. In updating the Indonesian seismic codes, seismic hazard maps for design also update, and there are changes to the Peak Ground Acceleration (PGA). Indonesian seismic design uses the concept of building performance levels consisting of Immediate occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). Related to this performance level, cases still found that buildings were damaged more than their performance targets after the earthquake. Based on the above issues, this study aims to analyze the performance of base isolation design on existing target buildings and analyze the seismic fragility for a case study in Indonesia. The target building is a prototype design 8-story medium-rise residential building using the reinforced concrete moment frame structure. Seismic fragility analysis uses Incremental Dynamic Analysis (IDA) with Nonlinear Time History Analysis (NLTHA) and eleven selected ground motions based on soil classification, magnitude, fault distance, and earthquake source mechanism. The comparison result of IDA shows a trend of significant performance improvement, with the same performance level target and risk category, the base isolation structure can be used at 1.46-3.20 times higher PGA than the fixed base structure. Then the fragility analysis results show that the fixed base structure has a safety margin of 30% and a base isolation structure of 62.5% from the PGA design. This result is useful for assessing existing buildings or considering a new building's performance.

The Estimation of the Floor Vibration in Structure for Application of Response Spectrum Analysis Method (응답스펙트럼 해석법을 이용한 건축 구조물의 바닥진동해석)

  • 이동근;김태호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.169-178
    • /
    • 1998
  • In general, the response spectrum analysis method is widely used for seismic analysis of building structures, and the time history analysis is applied for computation of structural vibration caused by equipments, machines and moving loads, etc. However, compared with the response spectrum analysis method, the time history method is very complex, difficult and time consuming. In this study, the maximum responses for the vertical vibration are calculated conveniently by the response spectrum method. At first, Response spectrum and time history analysis for some earthquake excitations are carried out, and the accuracy of maximum displacements obtained from response spectrum analysis is investigated. Secondly, the process for the response spectrum analysis in excitation is calculated, and the maximum modal responses are combined by CQC method. Finally, results of the proposed method are compared with those of the time history analysis.

  • PDF

A Study on the Utilization of History Culture Resources of Cultural Historic Village Project - Targeting Deokbongmaeul, Hoechonmaeul, Hyodongmaeul and Ipsanmaeul - (문화역사마을가꾸기 사업의 역사문화자원 활용 방식 고찰 - 덕봉마을, 회촌마을, 효동마을, 입산마을을 대상으로 -)

  • Kim, Dul-Y;So, Hyun-Su
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.1
    • /
    • pp.33-44
    • /
    • 2018
  • This study, targeting Deokbongmaeul, Choonchonmaeul, Hyodongmaeul and Kangsanmaeul, drew the characteristics of history culture resource utilization through the analysis of project plans and performance reports and field surveys. First, Deokbongmaeul is a rural village with scattered Confucian facilities. Ipsanmaeul conforms to Confucian order and has an attractive housing area landscape. Hoechonmaeul has forest landscape and distinguishing intangible recourses like Maeji farmer's music and traditional techniques and legends. Hyodongmaeul shows folk resources and folk behavior like traditional play and techniques. Second, the history culture resources chosen from the project plans focus on intangible history resources like individual historic buildings & structures and customs & traditional techniques. Third, cultural historic village projects are categorized by repair and restoration of historic buildings and structures, development of experience program and building facilities and maintenance and establishing the village landscape elements. From the research results, it is explained that history culture resource utilization methods of cultural historic village project are hard to be expected to have the project results based on the landscape identities of four villages.