• Title/Summary/Keyword: Building Heights

Search Result 167, Processing Time 0.028 seconds

A Study on the Reproduction of 3-Dimensional Building Model from Single High Resolution Image without Meta Information (메타정보 없는 단일 고해상도 영상으로부터 3차원 건물 모델 생성에 관한 연구)

  • Lee, Tae-Yoon;Kim, Tae-Jung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.3
    • /
    • pp.71-79
    • /
    • 2009
  • We expanded the 3D building information extraction method using shadow and vertical line from single high resolution image with meta information into the method for single high resolution image without meta information. Our method guesses an azimuth angle and an elevation angle of the sensor and the sun using reference building, selected by user, on an image. For test, we used an IKONOS image and an image extracted from the Google Earth. We calculated the Root Mean Square (RMS) error of heights extracted by our method using the building height extracted from stereo IKONOS image as reference, and the RMS error from the IKONOS image and the Google Earth image was under than 3 m. We also calculated the RMS error of horizontality position by comparison between building position extracted from only the IKONOS image and it from 1:1,000 digital map, and the result was under than 3 m. This test results showed that the height pattern of building models by our method was similar with it by the method using meta information.

  • PDF

Semi-Automatic Method for Constructing 2D and 3D Indoor GIS Maps based on Point Clouds from Terrestrial LiDAR (지상 라이다의 점군 데이터를 이용한 2차원 및 3차원 실내 GIS 도면 반자동 구축 기법 개발)

  • Hong, Sung Chul;Jung, Jae Hoon;Kim, Sang Min;Hong, Seung Hwan;Heo, Joon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2013
  • In rapidly developing urban areas that include high-rise, large, and complex buildings, indoor and outdoor maps in GIS become a basis for utilizing and sharing information pertaining to various aspects of the real world. Although an indoor mapping has gained much attentions, research efforts are mostly in 2D and 3D modeling of terrain and buildings. Therefore, to facilitate fast and accurate construction of indoor GIS, this paper proposes a semi-automatic method consisting of preprocessing, 2D mapping, and 3D mapping stages. The preprocessing is designed to estimate heights of building interiors and to identify noise data from point clouds. In the 2D mapping, a floor map is extracted with a tracing grid and a refinement method. In the 3D mapping, a 3D wireframe model is created with heights from the preprocessing stage. 3D mesh data converted from noise data is combined with the 3D wireframe model for detail modeling. The proposed method was applied to point clouds depicting a hallway in a building. Experiment results indicate that the proposed method can be utilized to construct 2D and 3D maps for indoor GIS.

Estimation Method of the Amount of Demolition Waste through Automated Calculation of Volumetric Spaces using Drones (드론 활용 체적산출 자동화를 통한 해체 폐기물량 예측기법에 관한 연구)

  • Ryu, Jung-Rim;Kim, Hye-Ri;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.681-688
    • /
    • 2022
  • In this study, the process of drone photography, automatic volume calculation, total floor area conversion, and waste calculation was constructed as a QGIS plug-in to predict the demolition waste (DW) generated in an aged area where drawing information or building information is uncertain. Through a case study, the high consistency between the automatically calculated volume using the drone and the BIM volume based on the field measurement was confirmed. Field application was carried out for the planned demolition work site, and the consistency between the drone-based volume and the actual measurement-BIM-based volume was reconfirmed. The waste generation unit was applied and the amount of DW was calculated by setting the floor height and building type, and the entire process was completed within 6 hours. Although the difference between building information and building objects through drones occurred according to the setting of temporary structures, loads, and floor heights, it was found that the actual amount of DW was generated more than the initial estimate. It is expected that measures to improve the accuracy of volume and floor area conversion will be required through case studies in the future.

The Effect of the Green Space in Roadside and Building Height on the Mitigation of Concentration of Particulate Matters (가로녹지 및 건물 높이가 미세먼지 농도에 미치는 영향)

  • Hong, Suk-Hwan;Tian, Wanting;Ahn, Rosa
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.5
    • /
    • pp.466-482
    • /
    • 2020
  • This study used 3D computational fluid dynamics (CFD) in the ENVI-met program to investigate how particulate matters (PM) generated on roads disperse through adjacent urban neighborhoods according to the urban development pattern. An urban area centered on a six-lane road in the vicinity of Miryang City Hall in Gyeongnam Province was selected to simulate the effect of the green space and building height on the PM concentration. The ENVI-met model considered the presence of green space and different building heights (high/low) on both sides of the road to examine the dispersion of PM. The result showed that the area of high-rise buildings and green space had the lowest PM concentration dispersed to the adjacent area, followed by the area of high-rise buildings and no green space. In contrast, the PM concentration remained relatively high for low-rise buildings, regardless of the green space. The reason for the low PM concentration in the area with high-rise buildings was a strong building wind, which caused PM to disperse to the outside, lowering the PM concentration quickly. These results indicate that the PM can disperse faster, and the PM concentration remains low in the urban neighborhood. On the other hand, green space had no significant effect on reducing PM in the urban neighborhood. In particular, when there are low-rise buildings on both sides of the road, the green space has no effect on the PM concentration in the urban neighborhood. Since this study considered only the case of PM emitted from the road, future studies should investigate other factors to figure out the dispersion model of PM and conduct on-site experiments.

A Study of the Work Efficiency in the High Altitude according to Climatic Elements (지역별 기후에 따른 고소작업가능률 산정 - 서울, 인천, 부산 지역을 중심으로 -)

  • Lee, Hyun-Soo;Cho, Sung-Jun;Park, Moon-Seo;Hwang, Sung-Joo;Kim, Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.3
    • /
    • pp.67-77
    • /
    • 2012
  • O Having a highly reliable plan for the process and estimating an accurate construction period during the early stages of a construction project can prevent falsifying the plan and reduce the occurrence of construction delays. Moreover, it allows a succession of swift and accurate decisions to happen. The difficulty in obtaining an accurate estimate of the construction period is especially prominent in high-rise building projects because the works involved are very complicated and costly. As such, it is important that research is done to find out the impacts a reliable plan and good estimate of the construction period can bring with regards to the monthly work efficiency and success of a high-rise building project. However, due to the difference in climatic conditions at high altitude and surface level, the current way of calculating work efficiency in a typical project is inaccurate for a high-rise building project. With that, this paper aims to compute the work efficiency with height, taking into consideration the change in climatic elements at different working heights. A comparison of the results according to the climatic features of each city can also be done in this paper. According to the results calculated in work altitudes, the work efficiency in Busan falls the most. On the other hands, the work efficiency in Seoul falls the least. The reason these results are shown is the influence of wind speed at high altitude. The estimation of work efficiency at high altitude would be used for estimating construction period, feasibility studies, and selecting a city of high-rise building projects.

Development of Estimation Method for Velocity Pressure Exposure Coefficient of Buildings Based on Spatial Information (공간정보기반 건축물의 풍속고도분포계수 산정 방법 개발)

  • SEO, Eun-Su;CHOI, Se-Hyu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.32-46
    • /
    • 2017
  • Recent rapid urban expansion and crowding of various industrial facilities has affected the features of a significant part of downtown area, resulting in areas having buildings with a wide range of height and the foothills. To compute a velocity pressure exposure coefficient, namely the design wind speed factor, this study defines ground surface roughness by utilizing concentration analysis for the height of each building. After obtaining spatial data by extracting a building layer from digital maps, the study area was partitioned for the concentration analysis and to allow investigation of the frequency distribution of building heights. Concentration analysis by building height was determined with the Variation-to-Means Ratio (VMR) and Poisson distribution analysis using a buildings distribution chart, with statistical significance determined using Chi-square verification. Applying geographic information systems (GIS) with the architectural information made it possible to estimate a velocity pressure exposure coefficient factor more quantitatively and objectively, by including geographic features, as compared to current methods. Thus, this method is expected to eliminate inaccuracies that arise when building designers calculate the velocity pressure exposure coefficient in subjective way, and to help increase the wind resistance of buildings in a more logical and cost-effective way.

Horizontal only and horizontal-vertical combined earthquake effects on three R/C frame building structures through linear time-history analysis (LTHA): An implementation to Turkey

  • Selcuk Bas;Mustafa A. Bilgin
    • Computers and Concrete
    • /
    • v.34 no.3
    • /
    • pp.329-346
    • /
    • 2024
  • In this study, it is aimed to investigate the vertical seismic performance of reinforced concrete (R/C) frame buildings in two different building stocks, one of which consists of those designed as per the previous Turkish Seismic Code (TSC-2007) that does not consider the vertical earthquake load, and the other of which consists of those designed as per the new Turkish Seismic Code (TSCB-2018) that considers the vertical earthquake load. For this aim, three R/C buildings with heights of 15 m, 24 m and 33 m are designed separately as per TSC-2007 and TSCB-2018 based on some limitations in terms of seismic zone, soil class and structural behavior factor (Rx/Ry) etc. The vertical earthquake motion effects are identified according to the linear time-history analyses (LTHA) that are performed separately for only horizontal (H) and combined horizontal+vertical (H+V) earthquake motions. LTHA is performed to predict how vertical earthquake motion affects the response of the designed buildings by comparing the linear response parameters of the base shear force, the base overturning, the base axial force, top-story vertical displacement. Nonlinear time-history analysis (NLTHA) is generally required for energy dissipative buildings, not required for design of buildings. In this study, the earthquake records are scaled to force the buildings in the linear range. Since nonlinear behavior is not expected from the buildings herein, the nonlinear time-history analysis (NLTHA) is not considered. Eleven earthquake acceleration records are considered by scaling them to the design spectrum given in TSCB-2018. The base shear force is obtained not to be affected from the combined H+V earthquake load for the buildings. The base overturning moment outcomes underline that the rigidity of the frame system in terms of the dimensions of the columns can be a critical parameter for the influence of the vertical earthquake motion on the buildings. In addition, the building stock from TSC-2007 is estimated to show better vertical earthquake performance than that of TSCB-2018. The vertical earthquake motion is found out to be highly effective on the base axial force of 33 m building rather than 15 m and 24 m buildings. Thus, the building height is a particularly important parameter for the base axial force. The percentage changes in the top-story vertical displacement of the buildings designed for both codes show an increase parallel to that in the base axial force results. To extrapolate more general results, it is clear to state that many buildings should be analyzed.

Tethers tension force effect in the response of a squared tension leg platform subjected to ocean waves

  • El-gamal, Amr R.;Essa, Ashraf;Ismail, Ayman
    • Ocean Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.327-342
    • /
    • 2014
  • The tension leg platform (TLP) is one of the compliant structures which are generally used for deep water oil exploration. With respect to the horizontal degrees of freedom, it behaves like a floating structure moored by vertical tethers which are pretension due to the excess buoyancy of the platform, whereas with respect to the vertical degrees of freedom, it is stiff and resembles a fixed structure and is not allowed to float freely. In the current study, a numerical study for square TLP using modified Morison equation was carried out in the time domain with water particle kinematics using Airy's linear wave theory to investigate the effect of changing the tether tension force on the stiffness matrix of TLP's, the dynamic behavior of TLP's; and on the fatigue stresses in the cables. The effect was investigated for different parameters of the hydrodynamic forces such as wave periods, and wave heights. The numerical study takes into consideration the effect of coupling between various degrees of freedom. The stiffness of the TLP was derived from a combination of hydrostatic restoring forces and restoring forces due to cables. Nonlinear equation was solved using Newmark's beta integration method. Only uni-directional waves in the surge direction was considered in the analysis. It was found that for short wave periods (i.e., 10 sec.), the surge response consisted of small amplitude oscillations about a displaced position that is significantly dependent on tether tension force, wave height; whereas for longer wave periods, the surge response showed high amplitude oscillations that is significantly dependent on wave height, and that special attention should be given to tethers fatigue because of their high tensile static and dynamic stress.

Calculation of Reasonable Equivalent Uniform Pressure Height and Lateral Earth Pressure Characteristics of Retaining Structures (옹벽에 작용하는 수평토압 특성 분석 및 합리적인 등가상재하중 높이 산정)

  • Lee, Kicheol;Chung, Moon-Kyung;Seo, Seunghwan;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.139-149
    • /
    • 2019
  • For retaining wall designs, horizontal earth pressure induced by traffic loads over the walls is calculated based on equivalent uniform pressure height. The AASHTO LRFD design standards propose equivalent uniform pressure height of traffic loads; however, the equivalent uniform pressure height is calibrated using the US standard trucks. As the domestic standard trucks are different from the US standard trucks, in this study, new domestic equivalent uniform pressure height is proposed using the Boussinesq theory varying vehicle directions, Poisson's ratios of pavement layers, and retaining wall height. The proposed equivalent uniform pressure heights are generally higher than those proposed by the AASHTO design standards because the axle loads and their densities of two domestic standard trucks are higher than those of the US standard trucks. The most highest equivalent uniform pressure height was found for traffic direction perpendicular to longitudinal direction of retaining wall.

Evaluation of Reduction in Reflection Sound bound from a Shaped Noise Barrier Panel (형상 방음벽 패널의 반사음 저감효과 평가)

  • Lee, Jaiyeop;Kim, Ilho
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.19-24
    • /
    • 2015
  • PURPOSES : The noise, which is typically generated by fast moving vehicles, can be intercepted by installing a noise barrier with a soundproof panel. However, reflections from the panels cause secondary noise, and hence lower the effectiveness of the panels. In this study, the reduction of reflection noise by considering the shape, especially zigzag one, of the soundproof panel have been evaluated. METHODS : The simulation model used in this study was Nord2000, which simulates real-road situations effectively. Based on the simulation results, the joining angle of $133^{\circ}$ with the pattern width (a) equal to 2 m and the projection height (b) equal to 0.5 m was adapted in the zigzag shape as the best profit designing factors. RESULTS: The measuring results at middle height, 15 m showed reduction at all points except the point with average -1.6 dB. At a greater height of 30 m, 2 points showed reduction. A real-sized facility was constructed to investigate the reflected sound from a zigzag shaped panel up to the height of 5 m. CONCLUSIONS: The reduction effects were detected in all the receive points in the range of 2-6 m distances and 1-5 m heights comparing the plane panel. Compared to plane panel, the noises are reduced at an average of 2.4 dBA.