• Title/Summary/Keyword: Building Greening

Search Result 57, Processing Time 0.027 seconds

The Post-occupancy Evaluation of Roofgarden at Hospital - A Case Study of Asan Medical Center - (병원 옥상정원의 이용후 평가 - 서울아산병원을 대상으로 -)

  • 김인혜;허근영;최아현;김유일
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.5
    • /
    • pp.58-72
    • /
    • 2003
  • Rooftop greenery has been used as a way to solve urban environmental problems by creating green space in densely populated cities. This study was carried out to suggest more effective designs for roof-garden at hospitals through a post-occupancy evaluation. The roofgarden of Asan Medical Center was evaluated with regards to setting, proximate environmental context, users, and design activity by a multi-method including plan investigations, observations, in-depth interviews and questionnaires. The results are summarized as follows; the users' main activities included resting, walking, and talking. A number of users were observed at shaded spaces sitting on such things as benches, pergolas, and shelters. The satisfaction of the users showed high satisfaction level except in the amount of shade, facilities, and shelter. The variables affecting a overall satisfaction were ‘accessibility’, ‘safety’, ‘quality of surroundings’, and ‘suitability for speculation’. By comparing the design concept with using pattern, designer's intention was not reflected sufficiently in several aspects such as ‘event deck for therapy programs’, ‘grove and path’, and ‘low planters’. This study suggests some design implications; it is necessary to furnish shaded sitting places for passive behaviors and pathways for walking or a light exercise. A wind-break wall with glass windows could widen the users' views in a limited space. Natural shade like tree shade or pergola are more desirable than artificial shades. As for the vertical location of the roofgarden, the middle floor could be better than top area for accessibility. Characteristics of building and users should be considered in detail to provide distinct spaces. Proper technical standards for the greening of artificial ground should be established.

A study on the low-carbon planning element and carbon reduction effect in public buildings -Focused on Cheongju city- (공공건축물의 저탄소 계획요소의 활용 및 탄소감축 효과분석 -충북 청주시 사례를 중심으로-)

  • Kim, Young-Hwan;Eo, Sang-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.3043-3051
    • /
    • 2013
  • As abnormal climate phenomena frequently happen due to the after-effect of the global warming, all nations suggest climate change response policies in many different fields to prevent global warming by reducing greenhouse gas. Especially, these days, the realization that the greenhouse gas from city buildings should be decreased is growing, and it is because that buildings are accounted for a quarter of national greenhouse gas emission and it is more than half the percentage of emissions within the city. Accordingly, Korean government sees the need to take an initiating role to fulfill low-carbon green policies and promotion strategies in the public sector, and wants to facilitate greenhouse gas reduction in the private sector as well. In this background, this study tries to examine the low-carbon planning element in public buildings and figure out the amount of carbon reduction and economic analysis centering Cheongju city as case study. Lastly, we propose some suggestion for low-carbon and greening of public buildings.

Change Soil Water and Evaluation with Respect to Shallow-Extensive Green Roof System (저토심 옥상녹화시스템에 따른 토양수분의 변화)

  • Park, Jun-Suk;Park, Je-Hea;Ju, Jin-Hee;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.843-848
    • /
    • 2010
  • This study focused on the characteristics of change soil water with respect to soil thickness and soil mixture ratio, in order to effectively carry out an afforestation system for a roof with a low level of management and a light weight. Soil hardness tended to increase as sand particle was increase regardless soil thickness and soil porosity had more higher artificial soil than natural soil mixture. In case of soil pH, natural soil mixture had between 6.7 and 7.4, and artificial soil mixture had 6.0~6.8. Organic matter, electrical conductance and exchangeable content were highest in $L_{10}$, which it had the highest leafmold ratio. Soil moisture tension(kPa) in 15cm soil thickness was observed natural soil mixture had a considerable change but artificial soil mixture had a gradual change when non-rainfall kept on. In the experimental $L_{10}$, $S_{10}$, $S_7L_3$ and $S_5L_5$ object, the amount of moisture tended to rapidly decrease. However, in the experimental $P_7P_1L_2$, $P_6P_2L_2$, $P_5P_3L_2$ and $P_4P_4L_2$ objects, which contained pearlite and peat moss, the amount of moisture tended to gradually decrease. As a result, the use of a artificial soil mixture soil seems to be required for the afforestation of a roof for a low level of management.

Simulating Carbon Storage Dynamics of Trees on the Artificial Ground (시뮬레이션을 통한 인공지반 교목의 탄소저장량 변화)

  • You, Soo-Jin;Song, Ki-Hwan;Park, Samuel;Kim, Se-Young;Chon, Jin-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.2
    • /
    • pp.11-22
    • /
    • 2017
  • To successfully create a low-carbon landscape in order to become a low-carbon city, it is necessary to understand the dynamics of artificial greening's resources on a multi-scale. Additionally, the effects of carbon storage should be quantitatively evaluated. The purpose of this study is to simulate and evaluate the changes in carbon storages of artificial ground trees using system dynamics throughout a long-term period. The process consisted of analyzing the dynamics of the multi-scale carbon cycle by using a casual loop diagram as well as simulating carbon storage changes in the green roof of the Gangnam-gu office building in 2008, 2018, 2028, and 2038. Results of the study are as follows. First, the causal loop diagram representing the relationship between the carbon storage of the artificial ground trees and the urban carbon cycle demonstrates that the carbon storage of the trees possess mutual cross-scale dynamics. Second, the main variables for the simulation model collected 'Biomass,' 'Carbon storage,' 'Dead organic matter,' and 'Carbon absorption,'and validated a high coefficient of determination, the value being ($R^2$=0.725, p<0.05). Third, as a result of the simulation model, we found that the variation in ranking of tree species was changing over time. This study also suggested the specific species of tree-such as Acer palmatum var. amoenum, Pinus densiflora, and Betula platyphylla-are used to improve the carbon storage in the green roof of the Gangnam-gu office building. This study can help contribute to developing quantitative and scientific criteria when designing, managing, and developing programs on low-carbon landscapes.

A field Study to Evaluate Cooling Effects of Green Facade under Different Irrigation Conditions - Focusing on modular green facade planted with Hedera helix L and Pachysandra terminalis - (관수조절에 의한 벽면녹화의 냉각효과 분석 연구- 아이비, 수호초를 식재한 모듈형 벽면녹화를 중심으로-)

  • Kim, Eun-Sub;Yun, Seok-Hwan;Piao, Zheng-gang;Jeon, Yoon-Ho;Kang, Hye-Won;Kim, Sang-Hyuck;Kim, Ji-Yeon;Lee, Young-Gu;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.6
    • /
    • pp.121-132
    • /
    • 2021
  • Green facade has a significant impact on building's energy performance by controlling the absorption of solar radiation and improving outdoor thermal comfort through shading and evapotranspiration. In particular, since high-density building does not enough green space, green facade, and rooftop greening using artificial ground plants are highly utilized. However, the level of cooling effect according to plant traits and irrigation control is different. Therefore, in this study, the cooling effect analyzed for a total of 4 cases by controlling the irrigation condition based on hedera and spurge. Although hedera under sufficient water had the highest cooling effect(-2℃~-4℃), had the lowest cooling effect under non-irrigation(+1.1℃~+4.4℃). In addition, hedera under sufficient water had cooling effect than hedera under non-irrigation(-1℃~-8.1℃) and in the case of spurge, it had cooling effect(-0.3℃~-7.8℃) more than non-irrigation. As a result of measuring the amount of transpiration according to the light intensity (PAR) and carbon dioxide concentration conditions, transpiration of hedera was higher than the spurge (respectively 0.63204mmolm-2s-1, 0.674367mmolm-2s-1). The difference in the cooling effect of the green facade under irrigation condition was significant. But the potential cooling effect of green facade according to plants species was different. Therefore, in order to maximize and continuously provide the cooling effect of green facade in urban areas, it is necessary to consider the characteristics of plants and the control of water supply through the irrigation system.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.

The Effect of Shading on Pedestrians' Thermal Comfort in the E-W Street (동-서 가로에서 차양이 보행자의 열적 쾌적성에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.60-74
    • /
    • 2018
  • This study was to investigate the pedestrian's thermal environments in the North Sidewalk of E-W Street during summer heatwave. We carried out detailed measurements with four human-biometeorological stations on Dongjin Street, Jinju, Korea ($N35^{\circ}10.73{\sim}10.75^{\prime}$, $E128^{\circ}55.90{\sim}58.00^{\prime}$, elevation: 50m). Two of the stations stood under one row street tree and hedge(One-Tree), two row street tree and hedge (Two-Tree), one of the stations stood under shelter and awning(Shelter), while the other in the sun (Sunlit). The measurement spots were instrumented with microclimate monitoring stations to continuously measure microclimate, radiation from the six cardinal directions at the height of 1.1m so as to calculate the Universal Thermal Climate Index (UTCI) from 24th July to 21th August 2018. The radiant temperature of sidewalk's elements were measured by the reflective sphere and thermal camera at 29th July 2018. The analysis results of 9 day's 1 minute term human-biometeorological data absorbed by a man in standing position from 10am to 4pm, and 1 day's radiant temperature of sidewalk elements from 1:16pm to 1:35pm, showed the following. The shading of street tree and shelter were mitigated heat stress by the lowered UTCI at mid and late summer's daytime, One-Tree and Two-Tree lowered respectively 0.4~0.5 level, 0.5~0.8 level of the heat stress, Shelter lowered respectively 0.3~1.0 level of the heat stress compared with those in the Sunlit. But the thermal environments in the One-Tree, Two-Tree and Shelter during the heat wave supposed to user "very strong heat stress" while those in the Sunlit supposed to user "very strong heat stres" and "exterme heat stress". The main heat load temperature compared with body temperature ($37^{\circ}C$) were respectively $7.4^{\circ}C{\sim}21.4^{\circ}C$ (pavement), $14.7^{\circ}C{\sim}15.8^{\circ}C$ (road), $12.7^{\circ}C$ (shelter canopy), $7.0^{\circ}C$ (street funiture), $3.5^{\circ}C{\sim}6.4^{\circ}C$ (building facade). The main heat load percentage were respectively 34.9%~81.0% (pavement), 9.6%~25.2% (road), 24.8% (shelter canopy), 14.1%~15.4% (building facade), 5.7% (street facility). Reducing the radiant temperature of the pavement, road, building surfaces by shading is the most effective means to achieve outdoor thermal comfort for pedestrians in sidewalk. Therefore, increasing the projected canopy area and LAI of street tree through the minimal training and pruning, building dense roadside hedge are essential for pedestrians thermal comfort. In addition, thermal liner, high reflective materials, greening etc. should be introduced for reducing the surface temperature of shelter and awning canopy. Also, retro-reflective materials of building facade should be introduced for the control of reflective sun radiation. More aggressively pavement watering should be introduced for reducing the surface temperature of sidewalk's pavement.