• Title/Summary/Keyword: Building External

Search Result 819, Processing Time 0.028 seconds

An Algorithm to Speed Up the Rapid Prototyping (쾌속조형의 속도를 향상시키기 위한 알고리즘)

  • Ko, Min-Suk;Chang, Min-Ho;Wang, Gi-Nam;Park, Sang-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.157-164
    • /
    • 2008
  • While developing physical prototype from CAD model, rapid prototyping mainly focuses on two key points reducing time and material consumption. So, we have to change from a traditional solid model to building a hollowed prototype. In this paper, a new method is presented to hollow out solid objects with uniform wall thickness to increase RP efficiency. To achieve uniform wall thickness, it is necessary to generate internal contour by slicing the offset model of an STL model. Due to many difficulties in this method, this paper proposes a new algorithm that computes internal contours computing offset model which is generated from external contour using wall thickness. Proposed method can easily compute the internal contour by slicing the offset surface defined by the sum of circle swept volumes of external contours without actual offset and the circle wept volumes. Internal contour existences are confirmed by using the external point. Presented algorithm uses the 2D geometric algorithm allowing RP implementation more efficient. Various examples have been tested with implementation of the algorithm, and some examples are presented for illustration.

A Subjective Evaluation on the Noise Environment of the Low-rise Multifamily House in Athens, U. S. A (미국 저층 공동주택 거주자의 소음 환경에 대한 주관적 평가 - Athens시를 중심으로 -)

  • 곽경숙
    • Korean Journal of Human Ecology
    • /
    • v.1 no.2
    • /
    • pp.61-74
    • /
    • 1998
  • The purpose of this study is to investigate residents subjective opinion of the noise on the low-rise multifamily house in U.S.A. The results of this study can be applied for the prevention of noise when planning cities, roads, and multifamily houses in Korea. The subjects of this study are three kinds of multifamily houses and their 109 residents in Athens, U.S.A. The results of this study are as follows. The residents felt the noise from lawn mowers and the sound from filter fans of air conditioners were higher than in the other external noise. The residents daily activities were disturbed a little by the external noise. Of the internal noise, the air home sound was recognized a little by residents. They only felt a moderate sound level from the building services of the solid borne sound. They suffered worse from noise in the summer and they felt worse from 16∼20 o'clock due to noise. The residents who were living in town houses felt better than those in the other multifamily houses. (Korean J Human Ecology 1(2):61∼74. 1998)

  • PDF

Output-only modal parameter identification for force-embedded acceleration data in the presence of harmonic and white noise excitations

  • Ku, C.J.;Tamura, Y.;Yoshida, A.;Miyake, K.;Chou, L.S.
    • Wind and Structures
    • /
    • v.16 no.2
    • /
    • pp.157-178
    • /
    • 2013
  • Output-only modal parameter identification is based on the assumption that external forces on a linear structure are white noise. However, harmonic excitations are also often present in real structural vibrations. In particular, it has been realized that the use of forced acceleration responses without knowledge of external forces can pose a problem in the modal parameter identification, because an external force is imparted to its impulse acceleration response function. This paper provides a three-stage identification procedure as a solution to the problem of harmonic and white noise excitations in the acceleration responses of a linear dynamic system. This procedure combines the uses of the mode indicator function, the complex mode indication function, the enhanced frequency response function, an iterative rational fraction polynomial method and mode shape inspection for the correlation-related functions of the force-embedded acceleration responses. The procedure is verified via numerical simulation of a five-floor shear building and a two-dimensional frame and also applied to ambient vibration data of a large-span roof structure. Results show that the modal parameters of these dynamic systems can be satisfactorily identified under the requirement of wide separation between vibration modes and harmonic excitations.

Damage-based stress-strain model of RC cylinders wrapped with CFRP composites

  • Mesbah, Habib-Abdelhak;Benzaid, Riad
    • Advances in concrete construction
    • /
    • v.5 no.5
    • /
    • pp.539-561
    • /
    • 2017
  • In this study, the effects of initial damage of concrete columns on the post-repair performance of reinforced concrete (RC) columns strengthened with carbon-fiber-reinforced polymer (CFRP) composite are investigated experimentally. Four kinds of compression-damaged RC cylinders were reinforced using external CFRP composite wraps, and the stress-strain behavior of the composite/concrete system was investigated. These concrete cylinders were compressed to four pre-damaged states including low -level, medium -level, high -level and total damage states. The percentages of the stress levels of pre-damage were, respectively, 40, 60, 80, and 100% of that of the control RC cylinder. These damaged concrete cylinders simulate bridge piers or building columns subjected to different magnitudes of stress, or at various stages in long-term behavior. Experimental data, as well as a stress-strain model proposed for the behavior of damaged and undamaged concrete strengthened by external CFRP composite sheets are presented. The experimental data shows that external confinement of concrete by CFRP composite wrap significantly improves both compressive strength and ductility of concrete, though the improvement is inversely proportional to the initial degree of damage to the concrete. The failure modes of the composite/damaged concrete systems were examined to evaluate the benefit of this reinforcing methodology. Results predicted by the model showed very good agreement with those of the current experimental program.

BASIC RESEARCH OF SUB-PACKAGE PROBLEM IN KOREAN CONSTRUCTION INDUSTRY

  • Jinho Shin;Furusaka Shuzo
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.635-641
    • /
    • 2009
  • In the building construction, the specialist contractors play the important roles in the point of the quality securing. Therefore, it is very important for the construction industry to study the sub-package problem. The sub-package problem includes two problems which should be solved. One is to decide the scope of works of each specialist contractor, and another one is to decide the particular specialist contractor which carries out the work. However, the sub-package problem in Korea is not clarified yet, although the circumstance around it has changed rapidly. Many factors influence to the sub-package problem regardless of internal factors or external factors of the project. The general contractor usually decides the sub-package under considering the project conditions. In case of the internal factors, each general contractor manages the organization and materials. But the external factors are relatively more difficult to control and predict than internal ones. But out of the external factors, the legal system has very close relationship with a sub-package problem especially in Korean construction system. So, this paper clarifies relationship between the legal system relating subcontracting and the state of sub-package.

  • PDF

A Study on the Prerequisite of the Net and Gross Area in General Hospital (종합병원의 순면적과 총면적 설정의 전제조건에 관한 연구)

  • Seong, Joon-Ho;Kim, Khil-Chae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.1
    • /
    • pp.53-60
    • /
    • 2012
  • Spatial configuration of the building quality relationships and reasonable distribution of space by utilizing the Net and Gross area. Therefore this study prerequisite for to investigate of Net and Gross area calculation in general hospital. For this study method as follow. First, a case study internal and external of net and gross area composition. Further more study on the other architect type. Second, a case study measuring area method for general hospital in internal and external. Finally, base on the analysis results of the drawn a net and gross area composition in general hospital.

Design of a Low-Power 500MHz CMOS PLL Frequency Synthesizer (저전력 500MHz CMOS PLL 주파수합성기 설계)

  • Kang, Ki-Sub;Oh, Gun-Chang;Park, Jong-Tae;Yu, Chong-Gun
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.485-487
    • /
    • 2006
  • This paper describes a frequency synthesizer designed in a $0.25{\mu}m$ CMOS technology for using local oscillators for the IF stages. The design is focused mainly on low-power characteristics. A simple ring-oscillator based VCO is used, where a single control signal can be used for variable resistors. The designed PLL includes all building blocks for elimination of external components, other than the crystal, and its operating frequency can be programmed by external data. It operates in the frequency range of 250MHz to 800MHz and consumes l.08mA at 500MHz from a 2.5V supply. The measured phase noise is -85dBc/Hz in-band and -105dBc/Hz at 1MHz offset. The die area is $1.09mm^2$

  • PDF

On site monitoring during nearby drilling operations toward a geothermal power system installation

  • Bortoluzzi, Daniele;Casciati, Sara;Faravelli, Lucia;Francolini, Matteo
    • Smart Structures and Systems
    • /
    • v.30 no.3
    • /
    • pp.317-325
    • /
    • 2022
  • Among the approaches to the production of "green" energy, geothermal power systems are becoming quite popular in Europe. Their installation in existing buildings requires an extended, external pipes appendix and its laying operation needs a drilling activities nearby structural skeletons often designed to support static loads only, especially when ancient buildings are targeted. This contribution reports and discusses the experimental results achieved within a specific case study within the European project GEOFIT. In particular, standard accelerometric measurements in and nearby a single-story reinforced concrete building are collected and analysed in the absence of drilling (pre-drilling) and during drilling activities (drilling phase) to monitor the structure response to the external source of vibrations related to the excavations phase. The target is to outline automatic guidelines toward installations preventing from any sort of structural damage.

Equivalent Viscous Damping Ratio of a Friction Damper Installed in a SDOF Building (단자유도 건물에 설치된 마찰감쇠기의 등가점성감쇠비)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.199-208
    • /
    • 2010
  • A friction damper installed at a building shows nonlinear behavior since its stick and slip states are occurred repeatedly depending on the amplitude of external loadings to dissipate input energy. Friction damping is existed for the building with a friction damper. In additionally viscous one is inherently included. Therefore, the building installed in such combined damping is quite involved to find the analytical solution. In this study, first, displacement and acceleration characteristics are identified based on the exact solution for a single-degree-freedom building with a friction damper having both friction and viscous damping. Second, in free vibration, the equivalent viscous damping ratio is obtained by the energy dissipation. Third, numerical analysis is carried out to find response configuration with various friction force ratios. Fourth, corresponding equivalent viscous damping ratio is derived with the finding that the response reaches into steady-state for both friction and viscous damped structure. It is deduced using balance of input external energy and output dissipation energy for steady-state response. Finally, the equivalent viscous damping ratios of free or harmonic vibration are verified through nonlinear analysis.

A Study on the Improvement of Pedestrian Environment for Greenways Construction (그린웨이 구축을 위한 보행환경 개선방안)

  • Han, Yujin;Kang, Junmo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.157-166
    • /
    • 2011
  • This study is to mention necessity of building Green-way by foreign theoretical backgrounds and analyzing cases of internal and external, and is purposed on assessment of projects in operation internal by above necessity. For these assessments, looking into cases of green-way plan of external and defining issues by comparing with internal cases to suggest solutions. Green-way planning methods can be classified in physical and non-physical aspects. From among these, for case of non-physical method, its environments of each nation, region, local are all different from each other and can not be turned into a numerical value and quantification, as well. Therefore, analyzing and suggesting the directions on the basis of physical method. Understanding the improvements degree of physical environment of before and after implementation of projects by using successful cases of external similar to actual state of internal. By these process, inflecting to suggest a seek way of applied to internal projects. Local aspects, doesn't have the specific analyzed data of improvement of pedestrian environment and building green-way and are shortage of implementation of projects also. For that reason this study is to look into the status and plans of building green-way in Seoul and analyzing the 7 completed region cases. And suggesting issues of projects and the direction of national and local green-way projects.