• Title/Summary/Keyword: Building Envelop

Search Result 31, Processing Time 0.021 seconds

An Analysis of Façade Panel Characteristics of UN Studio's Office Projects (유엔스튜디오 업무시설 외피 패널의 형태적 특성 분석)

  • Ko, Sung Hak
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.8
    • /
    • pp.23-34
    • /
    • 2019
  • The façade, a fundamental function as a skin that protects human life from external environment such as cold and hot weather, snow, rain, and wind, etc, has served as a media for communication between indoor space of the building and outside space. From the media for communication point of view, the approach to envelope design, in which environmental elements are transmitted internally through the filtering of external environments, has been evolving in various ways from the past to the present. Today, modern architecture technologies including curtain wall systems and user-friendly computer programming and environmental analysis programs demonstrate a differentiated approach to envelope design related to the indoor environment. For this reason, it is worth noting that the envelope design factors and trends that appear variously in the UNStudio's projects before and after the 2000s. The factors reflected in the envelop design in conjunction with the indoor environment obtained through the case study of the UNStudio's office projects were daylight environment, thermal environment, ventilation, noise, privacy and view, and consideration for daylight environment and thermal environment was reflected in many cases through the case study. Looking at the changes in the diagrams in order of year, it can be seen that the envelope design using the environmental analysis tool has been performed since 2006. This is a clue to show the envelop design changes from the conceptual method to the data-based one. The diagrams and analysis results related to the envelop design showed that the thermal environment related to solar radiation was the most, and no diagrams and analysis related to the indoor illumination were found. Since 2010, PV panel installation has been shown in the envelope design, which can be found in the increased efficiency of PV panels due to the technological advances and the decrease in production cost.

Analysis of the Impacts of Stack Effect in High-rise Residential Buildings (초고층 주거용 건물에서의 연돌효과 영향 분석)

  • 양인호;조재훈;김광우;여명석
    • Journal of the Korean housing association
    • /
    • v.13 no.4
    • /
    • pp.61-66
    • /
    • 2002
  • The objectives of this study are to clarify the impacts of stack effect in high-rise residential buildings and to present technical methods to reduce stack effect. For the evaluation of stack effect, architectural design guidelines were used and computer program simulations based on network model were performed. The evaluation shows that problems due to stack effect may be reduced by appropriate architectural designs, such as increase in air-tightness of building envelop, and provision of vestibules around entrance and elevator hall doors.

Design of a Linear Mass Excitation System for Simulating Wind-induced Responses of a Building Structure (풍하중 구현 및 내풍특성 평가를 위한 선형질량 가진시스템 설계)

  • Park, Eun-Churn;Lee, Sang-Hyun;Min, Kyung-Won;Kang, Kyung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.661-668
    • /
    • 2007
  • In this paper, excitation systems using linear mass shaker (LMS) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop function are used such that the error between the wind and actuator induced responses is minimized by preventing the actuator from exciting unexpected modal response and initial transient response. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

  • PDF

Design of an actuator for simulating wind-induced response of a building structure

  • Park, Eun Churn;Lee, Sang-Hyun;Min, Kyung-Won;Chung, Lan;Lee, Sung-Kyung;Cho, Seung-Ho;Yu, Eunjong;Kang, Kyung-Soo
    • Smart Structures and Systems
    • /
    • v.4 no.1
    • /
    • pp.85-98
    • /
    • 2008
  • In this paper, excitation systems using a linear mass shaker (LMS) and an active tuned mass damper (ATMD) are presented to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop functions are used to prevent the actuator from exciting unexpected modal responses and an initial transient response and thus, to minimize the error between the wind and actuator induced responses. The analyses results from a 76-story benchmark building problem for which the wind load obtained by a wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately reproduce the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

Insulation Saving Effect for Korean Apartment House Using Cross-Laminated Timber (CLT)

  • Pang, Sung-Jun;Lee, Bumjin;Jeong, Gi Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.846-856
    • /
    • 2017
  • The aim of this study was to develop the details of cross-laminated timber (CLT) envelops for satisfying the design standard for energy saving (DSEA) and passive standard in South Korea. When the same thickness of 180 mm concrete or CLT was used and the same materials for other layers were used for the roof, wall, and interlayer floor, the required insulation thickness for the different building envelopes in central, southern, and Jeju island was evaluated. As a result, compared to the concrete envelop, about 43 mm of insulation thickness was reduced for wall and roof with the CLT envelope. When the CLT envelopes were modified to protect the CLT from moisture based on FPInnovations (2011), the insulation thickness was further reduced by 12 mm. When the modified CLT building envelops satisfied with a passive standard are used for 10-story building, the required insulation was decreased by $40.89m^3$ for a floor ($105.27m^2{\times}2.3m$ in height) compared to concrete building. As the number of floors increases, about 3.58 m3 of insulation per floor was additionally saved.

BIM Energy Efficiency Plan for Verification of Building Envelop Energy Code of Housing in USA - Based on the NYC Energy Conservation Code - (미국 공동주택의 건물 외피 에너지코드 검증을 위한 BIM 에너지 계획 방안 -뉴욕시 에너지 코드를 기준으로-)

  • Heo, Jinwoo
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.313-322
    • /
    • 2022
  • The number of architects who adopt BIM(Building Information Modeling) as the design method are gradually increasing because of its productivity and efficiency. Climate Change and Global Warming lead to legislation of new energy regulations and strengthen existing ones. The current architectural design methods (2D CAD) take a lot of time and effort to verify energy codes and are hard to adjust according to the design changes. The purpose of this study is to show the effectiveness of the BIM in building envelop energy modeling of the housing project. In the process of design method change, We could contribute to increasing productivity and efficiency in building energy verification through BIM because the updated value could be calculated simultaneously without information omission or recalculation process. The procedure for the study is as follows. Using BIM of the Goldin at Essex Crosing Housing Project by Revit 2011 as a case model, this study analyze the criteria for energy plan to conform to the energy code in NYC. The result value from the setting of the Revit model is compared with the reference value required by the NYC Energy Code. Finally, the data from BIM are entered into COMckeck, the energy verification program provided by U.S. Department of Energy, to check whether the building envelope energy performance conforms to NYC Energy Code.

An Energy Performance Evaluation of UFAD System under the Various Conditions of Thermal Load (실내 부하조건에 따른 바닥공조 시스템의 에너지 성능 평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Kim, Kyung-Ah;Yu, Ki-Hyung;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • The present study has been conducted for evaluating and comparing the performance of the underfloor air distribution system(UFAD) and the ceiling based air distribution system(CBAD) under cooling condition. Simulations and experiments were carried out for verifying the model by TRNSYS program about UFAD and CBAD. The results of simulation for various conditions of thermal load are summarized as followings. UFAD had an advantage for making thermal comfort because of lower temperature of the floor surface. Moreover, UFAD showed lower fan power about 30~50% than CBAD under the same conditions of thermal load. The energy saving rates of UFAD were increased to 17.7% in proportion to the thermal load on unoccupied zone(lighting). Ultimately, additional investigations should be done for analyzing optimized operating conditions of UFAD with considering the thermal performance of building envelop and the thermal load.

Evaluation of Condensation Prevention for Centralized Hybrid Ventilation System Using TDR (TDR을 이용한 중앙집중형 하이브리드 환기시스템의 결로방지 성능 평가)

  • Kim, Yu-Min;Lee, Jong-Eun;Choi, Gyeong-Seok;Lee, Yong-Jun;Kang, Jae-Sik
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose: Condensation in the apartment housing is one of the most significant defects and complaints for condensation are rapidly increasing according to the growing interest in residential environment. Korea government established a regulation for reducing condensation in the apartment housing and TDR is adapted as a standard. However prevention of condensation depend on improving the performance of building envelop has limitation because of the increase of the cost. Centralized Hybrid ventilation system is suggested to prevent condensation. Method: Field measurement was conducted to verify the ventilation rate of the ventilation system. Based on the measurement, air network and CFD simulation was conducted to analyze ventilation rate for each room. Surface temperature was calculated by regulated TDR according to the regions and surfaces. The performance of condensation prevention was evaluated by the ventilation rate and surface temperature. Result: In the results, it was found that condensation was prevented in more than 90% of households by the centralized hybrid ventilation system which provided 0.19 ~ 0.81ACH for each room.

The Evaluation of Ceiling Depth Impact on Lighting and Overall Energy Consumption of a Building with Top-lighting System

  • Amina, Irakoze;Kee, Han Ki;Lee, Young-A
    • Architectural research
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • The purpose of this study was to evaluate the variation in building energy predictions caused by simulation settings related to building envelop thickness. The study assessed the ceiling depth impact on skylight energy performance through OpenStudio integrated Radiance and EnergyPlus simulation programs. A ceiling as deep as 1.5 to 3m was analyzed for skylight to roof ratios from 1% to 25%. The results indicated that the building ceiling depth negatively affected the capability of skylights to significantly reduce building energy consumption. Through a parametric analysis, the study concluded that 8%, 9%, 10% and 11% skylight to roof ratio were optimal in terms of total building energy consumption for a ceiling depth of 1.5m, 2m, 2.5m and 3m, respectively. In addition, the results showed that the usually recommended 5% skylight to roof ratio was only efficient when no ceiling depth was included in the simulation model. Furthermore, the study indicated that the building energy saved by the optimal skylight of each ceiling depth decreased as the ceiling depth deepened. The highest total building energy reduction was 9%, 7%, 5% and 3% for a ceiling depth of 1.5m, 2m, 2.5m and 3m, respectively. This study induced that the solar heat gains and daylight visible transmittance by ceiling depth were crucial in the predictions of skylight energy performance and should not be neglected through building simulation simplifications as it is commonly done in most simulation programs' settings.

A Study on Envelope Design Variables for Energy Conservation of General Hospital Ward Area by Sensitivity Analysis (민감도 분석을 통한 종합병원 병동부의 에너지 절감 외피 설계요소 도출)

  • Oh, Jihyun;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • Purpose: Since the large hospitals are one of the most intensive energy users among building types in Korea, it is important to investigate and apply appropriate energy conservation measures. There are many researches on energy conservation measures for HVAC system in hospitals, but only few useful guidelines for envelope design variables were existed. The building envelope is one of the important factors to building energy consumption and patients' comfort. The purpose of this study is to suggest the most influential envelope design variables for each end-use energy demand. Methods: 100 samples were generated by LHS(Latin Hypercube Sampling) method. After energy performance simulation, global sensitivity analysis was performed by the regression method. DesignBuilder, Simlab 2.2 and JEPlus were used in this process. Results: The most influencing variables are SHGC, SHGC and VT for heating, cooling, and lighting, respectively. However, the most influencing variable for total energy demand is WWR(Window to Wall Ratio). The analysis was conducted based on the coefficient of variance results. Implications: The six envelop design variables were ranked according to the end-use energy demand.