• 제목/요약/키워드: Building Energy Simulation

검색결과 681건 처리시간 0.021초

반능동 MR 유체 감쇠기를 이용한 지진하중을 받는 구조물의 신경망제어 (Neuro-Control of Seismically Excited Structures using Semi-active MR Fluid Damper)

  • 이헌재;정형조;오주원;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.313-320
    • /
    • 2002
  • A new semi-active control strategy for seismic response reduction using a neuro-controller and a magnetorheological (MR) fluid damper is proposed. The proposed control system consists of the improved neuro-controller and the bang-bang-type controller. The improved neuro-controller, which was developed by employing the training algorithm based on a cost function and the sensitivity evaluation algorithm replacing an emulator neural network, produces the desired active control force, and then the bang-bang-type controller causes the MR fluid damper to generate the desired control force, so long as this force is dissipative. In numerical simulation, a three-story building structure is semi-actively controlled by the trained neural network under the historical earthquake records. The simulation results show that the proposed semi-active neuro-control algorithm is quite effective to reduce seismic responses. In addition, the semi-active control system using MR fluid dampers has many attractive features, such as the bounded-input, bounded-output stability and small energy requirements. The results of this investigation, therefore, indicate that the proposed semi-active neuro-control strategy using MR fluid dampers could be effectively used for control of seismically excited structures.

  • PDF

예측 냉방부하를 이용한 빙축열시스템의 최적 운전계획 (Optimal Scheduling of Ice Storage System with Prediction of Cooling Loads)

  • 이경호;최병윤;주용진;이상렬;한승호
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.982-993
    • /
    • 2000
  • This paper describes an optimal control scheduling of an encapsulated ice storage system with a chiller of nominal chiller 34RT(103,200kcal/hr) and an ice storage tank of 170RT-hrs(514,080 kcal). The optimization technique used in the study is dynamic programing. The objective function is summed cost during a day including charge and discharge periods. Control strategies being used commercially are chiller priority and storage priority control. In chiller priority control, the chiller is allowed to run at full capacity during the day, subject to limitations of the building load, and the ice is only melted when and if the load exceeds the chillers full capacity. In contrast to chiller priority control, the aim in storage priority control is to melt as much as ice as possible during the day time period. The system simulation calculates the operation costs for the three control strategies in the condition of the same cooling load and the same ice storage system. The simulation period is a day, assuming that initially the tank is stored fully and the cooling load is perfectly predicted for the scheduling. Also Final state of the tank is to be charged fully.

  • PDF

외부바람과 연돌효과의 상호작용에 의한 고층주거 건물의 연간 침기량 분포 (The annual infiltration distribution caused by wind and stack effects in high-rise residential buildings)

  • 박주현;윤성민;송두삼;김용식
    • 도시과학
    • /
    • 제8권1호
    • /
    • pp.25-31
    • /
    • 2019
  • Infiltration affects indoor environmental and air quality and energy consumptions in buildings. Especially, airflow and the infiltration are more remarkable in high-rise buildings due to the air-driving forces (stack and wind effects). Thus, it is important to understand infiltration distributions in high-rise residential buildings. In this study, the weather-driven infiltration is characterized from the viewpoint of interactions between external wind and stack effect in high-rise residential buildings. To calculate accurately the annual infiltration distributions, this study also suggests an airflow and thermal simulation method with a two-step calibration of air-leakage data. The simulated results show (1) how the interaction between stack and wind effects induce infiltration types (outdoor and interzone air infiltration) and (2) how much the interzone air infiltration (being ignored in previous studies) occurs due to the stack effect, as well as the outdoor air infiltration rates.

WUFI 시뮬레이션 프로그램을 이용한 목조주택 벽체 레이어 구성에 따른 hygrothermal 성능 평가 (Evaluation of The Hygrothermal Performance by Wall Layer Component of Wooden Houses Using WUFI Simulation Program)

  • 강유진;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.75-84
    • /
    • 2016
  • 건물에너지 저감에 효과적으로 기여하는 건축 재료를 이용하는 목조주택을 기반으로 단열 성능이 향상되고 있다. 그러나 고단열 고기밀화로 인한 습기 제어가 어려워져 외벽의 결로 및 곰팡이 발생으로 인하여 성능이 저하될 수 있다. 이에 열 습기 시뮬레이션 프로그램을 이용하여 선정한 5가지 형태의 목조주택 외벽의 열 습기 성능, 결로 발생 및 곰팡이 성장 위험을 평가하였다. 목조주택은 농촌주택 표준설계도 '10과 '14, $2^{{\prime}{\prime}}{\times}6^{{\prime}{\prime}}$형, EIFS 그리고 목조형 패시브 하우스로 선정하였고, 각 벽체 레이어를 구성에 따라 벽 A, B, C, D, E로 구분하였다. 벽체의 열관류율은 각각 0.171, 0.172, 0.221, 0.150, $0.079W/m^2K$이다. 벽 A와 C의 OSB 절대함수량은 기준치 20%를 초과하는 값이 나타났고, 결로 평가를 통하여 단열재 내부 표면에서 겨울철에 결로가 발생할 수 있음을 확인하였다. 벽 D와 E는 외단열 벽체로 다른 벽체에 비하여 함수량 평가와 결로 평가에서 우수한 결과를 보여주었다. 그러나 곰팡이 성장 위험 평가에서 5가지 형태의 벽체 모두 곰팡이 성장 위험성이 있음을 확인하였다. 이에 따라 외벽의 열 습기 성능의 차이는 열적 성능에 의한 발생보다는 레이어 구성에 따른 차이가 발생하는 것으로 판단되었다. 모든 벽체는 비슷한 열적 성능을 가지고 있으나 레이어에 따라 동일한 조건에서의 적합성이 다르게 나타나는 것을 확인하였다.

공공건축물의 그린리모델링 수준별 LCC (Life Cycle Cost) 분석을 통한 경제성 비교 (The Economic Comparision through LCC Analysis on each Graded Alternatives for Green Remodeling of Public Building)

  • 김재문;이정혁;이두환
    • 한국건설관리학회논문집
    • /
    • 제19권2호
    • /
    • pp.38-49
    • /
    • 2018
  • 파리협약 비준 이후 온실감축에 대한 중요성 및 국가 의무가 커짐에 따라 정부에서는 건축산업의 온실가스 감축을 위한 정책을 지속적으로 강화해 나가고 있으며, 특히 노후건축물에 대한 에너지 성능개선의 필요성을 강조하고 있다. 2014년 이후 정부에서는 공공 노후건축물 그린리모델링 사업의 시공비 지원 등으로 시범사업을 운영 중에 있으며 이를 통해 그린리모델링의 모범사례를 개발하여 민간에 그린리모델링을 활성 시키고자 한다. 본 연구에서는 공공 노후건축물의 그린리모델링을 통한 수준별 경제성을 분석하였으며, 해당건물의 대안을 계획하기 위해 건물 육안조사 및 장비측정을 수행하였다. 개선안은 대안을 종합한 그린리모델링 계획안으로 수준별 5개의 개선안을 개발하여 각 안에 대한 경제성을 분석하였다. 분석방법은 ECO2를 통한 1차 에너지소요량 산정 및 LCC 분석을 진행하였으며, LCC 측면에서는 개선 3, 4안(중간수준 안)이 가장 우수한 것으로 분석되었으며, 다음으로 최대비용안, 최소 비용 안 순으로 결과가 도출되었다. 이 결과로 향후 진행될 그린리모델링 성능계획 및 경제성 분석 시 기초자료로서 활용이 가능 할 것으로 예상된다.

급기제트 조건에 따른 냉동용 전시케이스의 성능 (Performance of Refrigerated Display Cabinets in accordance with the Supply Air Jet Condition)

  • 성순경
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.80-86
    • /
    • 2011
  • Vertical open display cabinets are widely used in shopping mall, supermarkets, retail stores. Maintaining the temperature of foods in the display cabinet is vitally important to retailers to ensure optimal food quality and safety. The purpose of this study is to reduce the infiltration of air and heat loss from ambient space to display cabinet. The three-dimensional Computational Fluid Dynamics(CFD) simulation is used for the analysis of air flow patterns and temperature distribution in refrigerated display cabinets. Under several operating conditions which vary both the inner and outer jet velocities in the range from 0.3 to 1.1 m/s, simulations were carried out. This paper presents a performance of display cabinets with single jet and double jet. The energy consumption due to thermal entrainment ratio is plotted with varying Re. It was found that the double jet system is better than single jet system in terms of temperature distribution and energy saving.

지하수 히트펌프 시스템의 대수층 활용 사레 연구 (Study on the aquifer utilization for a ground water heat pump system)

  • 심병완;이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

Design of a decoupled PID controller via MOCS for seismic control of smart structures

  • Etedali, Sadegh;Tavakoli, Saeed;Sohrabi, Mohammad Reza
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1067-1087
    • /
    • 2016
  • In this paper, a decoupled proportional-integral-derivative (PID) control approach for seismic control of smart structures is presented. First, the state space equation of a structure is transformed into modal coordinates and parameters of the modal PID control are separately designed in a reduced modal space. Then, the feedback gain matrix of the controller is obtained based on the contribution of modal responses to the structural responses. The performance of the controller is investigated to adjust control force of piezoelectric friction dampers (PFDs) in a benchmark base isolated building. In order to tune the modal feedback gain of the controller, a suitable trade-off among the conflicting objectives, i.e., the reduction of maximum modal base displacement and the maximum modal floor acceleration of the smart base isolated structure, as well as the maximum modal control force, is created using a multi-objective cuckoo search (MOCS) algorithm. In terms of reduction of maximum base displacement and story acceleration, numerical simulations show that the proposed method performs better than other reported controllers in the literature. Moreover, simulation results show that the PFDs are able to efficiently dissipate the input excitation energy and reduce the damage energy of the structure. Overall, the proposed control strategy provides a simple strategy to tune the control forces and reduces the number of sensors of the control system to the number of controlled stories.

알루미늄 판재의 성형성 향상을 위한 적외선 국부 열처리법의 곡선형태 적용에 관한 연구 (A Study on the Infrared Local Heat Treatment of Curved Line for Aluminum Alloy Sheet)

  • 이은호;양동열
    • 소성∙가공
    • /
    • 제27권2호
    • /
    • pp.87-92
    • /
    • 2018
  • Auto industries have tried to employ lightweight alloys to improve the fuel efficiency of manufactured vehicles, as the environmental concern becomes an important issue. Even though the aluminum alloy is one of the most appropriate lightweight alloys for auto parts, the low formability of an aluminum alloy has been an obstacle to its application. In order to resolve the low formability problem, a recent study (Lee et al., 2017 [1]) showed that the infrared (IR) local heat treatment can improve the formability with a reduction of heating energy. However, the aforementioned study was limited to only a linear line heating. Since many of the available auto parts as applicable to vehicle manufacturing have a curved line shape, the heating experiments for a curved line should be studied. The possibility of building IR lamps having complex shapes is an advantage of the IR lamp, since it can control the heating shape. This work conducted the IR local heat treatment for the curved line. The experimental results show that the IR local heat treatment can improve the formability of the aluminum alloy for curved line. Additionally, it is shown that the IR local heat treatment also reduces the heating energy when it is compared with the furnace heating which heats a blank as a whole. A numerical simulation with a stress-based forming limit diagram also supports the experimental results.

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF