Analysis of Energy Performance & Energy Saving with Geothermal Heat Pump System Using TRNSYS Program in a Large Scale Shopping Store (TRNSYS 프로그램을 이용한 대형쇼핑매장 에너지성능해석 및 지열시스템을 도입하는 경우 에너지절약 특성분석)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.47-56
    • /
    • 2015
  • Energy consumption in buildings is currently a real problem. That is why both assessment of energy performance and effective energy management including renewable energy system are essential. Thus, this paper focuses on a case study to analyze the energy performance and cooling & heating energy saving of a large scale shopping store in Daejeon city. The reference building is simulated by using TRNSYS dynamic simulation tool to examine its annual energy consumption. For annual energy analysis of building, one year energy consumption is surveyed in the field. The related study is carried out in large scale shopping store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and other. The evaluation of energy performance of the geothermal heat pump system installed in a large scale shopping store is also analyzed by TRNSYS tool. From simulation results, it evaluated that the geothermal heat pump system is effective energy savings method in large scale shopping store.

A Study of applying VAV and VWV System to reduce Energy Consumption of Office building (VAV 및 VWV시스템 적용에 따른 업무용 건축물의 에너지저감에 관한 연구)

  • Song, Ji-Yong;Hong, Won-Hwa;Kim, Ji-Yeon;Park, Hyo-Soon
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • Building Energy Efficiency Rating system was enforced in 2001 to enhance spreading high-energy performance and saving buildings. It was only for the new apartments, but expanded to new office buildings in 2010, and moreover, government offices require 1st grade of Building Energy Efficiency Rating system. Green Building Act, which is established to reduce the emissivity of carbon dioxide by reducing building energy consumption, will be enforced in 2013, and new apartments and office buildings will be subjected to it. Henceforward, it will extend to other types of buildings and will be phased in. In general, pumps and fans consume approximately half of the air-conditioning energy consumption, and about a quarter of the total building energy consumption when office buildings have total floor area of more than 10000 square meters. This study analyzed the energy demand when applying VAV(Variable Air Volume) and VWV(Variable Water Volume) System to reduce energy returns of the pumps and the fans by ECO2, which is a computer simulation program used for Building Energy Efficiency Rating system.

A Study on the Evaluation Method for the Degree of Integration towards Office Towers in Different Climate Zones

  • Han, Seung-Hoon;Moon, Jin Woo;Kim, Kyoung-Hee
    • Architectural research
    • /
    • v.14 no.4
    • /
    • pp.117-124
    • /
    • 2012
  • High rise office buildings represent one of the most energy-intensive architectural typologies. The growth of urban population necessitates sustainable high rise towers that lessen environmental impacts and energy consumption. Among various sustainable strategies, the integrated design is long known to be an important process that has great impact on building's sustainability. The framework for this paper is based on the case study of integrated towers that are located in different climate zones. The paper specifically addresses to what extent climate conditions influence the design of a high rise building and what kinds of the climate integrated design has been implemented. Qualitative case studies were carried out using published data and architectural drawing set. The technical work presented in the paper is based on computer simulation that examines the insolation analysis using hourly recorded weather data. The analysis results revealed that the site and building envelope integration and the site and building service systems have shown the most frequently employed in the integrated towers through the implementation of renewable resource integration, high performance envelopes and sustainable building service systems. Internal comfort and further energy saving in the integrated towers are offered through an automatic building management system. Due to the dynamic climate conditions, integration of building systems requires a sophisticated approach to building sustainability.

Heating Performance and Energy Consumption Characteristics with Control Strategies for Central Heating System (중앙난방시스템의 제어방법에 따른 난방성능 및 에너지소모량 특성 연구)

  • Song, Jae-Yeob;Yang, Wan-Youn;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.38-44
    • /
    • 2011
  • In this study, heating performance and energy consumption characteristics with control strategies for central heating system were researched by the simulation. The simulation analysis is made by TRNSYS ver. 15 with the actual data. The parametric study on proportional factor, control time interval and outdoor air temperatures changes were done to compare control characteristics and energy performance, respectively. As a result, the simulation results with various parameter changes show good heating performance and energy saving.

An Energy Performance Comparison of University Lecture Facilities for Energy Saving Building Design (에너지 절약형 건축물 설계를 위한 대학 강의동 형태별 에너지 성능 비교에 관한 연구)

  • Kim, Tae-Hoon;Seo, Ji-Hyo;Choo, Seung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.105-112
    • /
    • 2018
  • Global environmental problems are growing, and the importance of buildings with high energy consumption has been emphasized. In Korea, the Ministry of Land, Transport and Maritime Affairs has been promoting the mandatory zero energy building since 2020, and guidelines related to the zero energy building have been developed. In addition, based on the "Energy-saving Design Criteria for Buildings" of the "Green Building Promotion Act" in Korea, the standards for energy-saving design are specified and the energy saving plan is written. Besides, the 'Energy-saving construction standards for eco-friendly houses' also specify insulation, machinery, equipment, and sunshade. Also, there is little consideration about the cost such as construction cost and material cost which should be considered important in the construction stage. Therefore, this study aims at analysis of building type and energy performance versus materials for energy saving building design considering energy performance in planning aspect of initial design stage. In this study, because the variables can not be neglected in this study, it is selected as the lecture facility of the 'K' university campus building which can consider the remaining factors except the passive design element as the control variable, Energy performance analysis.

Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season (겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구)

  • Lee, Ki Yong;Kim, Kee Han;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.110-114
    • /
    • 2016
  • Newly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over $16^{\circ}C$ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452\/household in Incheon city and from 3,521 to 26,268\/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.

Optimal air-conditioning system operating control strategies in summer (여름철 공조시스템의 최적 운전 제어 방식)

  • Huh, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.410-425
    • /
    • 1997
  • Buildings are mostly under part load conditions causing an inefficient system operation in terms of energy consumption. It is critical to operate building air-conditioning system with a scientific or optimal manner which minimizes energy consumption and maintains thermal comfort by matching building sensible and latent loads. Little research has been performed in developing general methodologies for the optimal operation of air-conditioning system. Based on this research motivation, system simulation program was developed by adopting various equipment operating strategies which are energy efficient especially for humidity control in summer. A numerical optimization technique was utilized to search optimal solution for multi-independent variables and then linked to the developed system simulation model within a mam program. The main goal of the study is to provide a systematic framework and guideline for the optimal operation of air-conditioning system focusing on air-side. For given cooling loads and ambient outdoor conditions the optimal operating strategies of a commercial building are determined by minimizing a constrained objective function by a nonlinear programming technique. Desired space setpoint conditions were found through evaluating the trade-offs between comfort and system power consumption. The results show that supply airflow rate and compressor fraction play main roles in the optimization process. It was found that variable setpoint optimization technique could produce lower indoor humidity level demanding less power consumption which will be benefits for building applications of humidity problem.

  • PDF

Comparative Analysis of Energy Performance using Dynamic Simulation (동적 시뮬레이션을 이용한 건물 에너지 성능 비교분석)

  • Bae, Sangmu;Lee, Kyung-Hee;Yeo, Seong-Gu;Kim, Eunji;Yang, Jae-Kwang;Jeon, Jae-Young;Lee, Joonhyuk;Bae, Yeongmin;Kim, Sung-Hoon;Kang, Youngmo
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.62-67
    • /
    • 2017
  • In order to achieve high efficiency of energy use and environment-friendly architectural design, various loads such as cooling, heating and hot water required by the building sector must be accurately predicted. Many studies used dynamic simulation tool to evaluate and analyze building energy performance. However, there are few studies on the comparative analysis of load results by each simulation and the evaluation of simulation characteristics and functions. In this study, the cooling, heating loads and energy demand of the buildings were evaluated using three dynamic simulations for the building with the same input conditions, and the characteristics of each simulation were compared and analyzed through the results. As a result of simulation comparative analysis, cooling, heating load and energy demand was lowest in square type and north-south direction conditions.

Sensitivity Analysis of Building Envelope of Non-Dwelling Buildings (비주거 건축물의 외피요소에 대한 민감도 분석)

  • Kim, Kyung-Ah;Park, Jin-Seo;Yu, Ki-Hyung;Moon, Hyeun-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • The ECO2 building energy simulation program is used on the assessment project for building energy certification of non-dwelling buildings in Korea. In the design of energy efficient buildings, it is beneficial to identify the most important design parameters in oder to more efficiently develop alternative design solutions or reach optimized design solutions. The sensitivity analyses will be used at a reasonable early stage of the building design process, where it is still possible to influence the most important design parameters. In this study, the sensitivity analysis is focused on building envelope parameters such as U-values, SHGC and Wall-window ration.

The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings (Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석)

  • Hwang, Woo-Jin;Kim, Kyo-Joon;Choi, Won-Ki
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF