• 제목/요약/키워드: Building Energy Simulation

검색결과 681건 처리시간 0.025초

Interface treatment in shotcrete jacketing of reinforced concrete columns to improve seismic performance

  • Vandoros, Konstantinos G.;Dritsos, Stephanos E.
    • Structural Engineering and Mechanics
    • /
    • 제23권1호
    • /
    • pp.43-61
    • /
    • 2006
  • An investigation of the effectiveness of the interface treatment when column concrete jacketing is performed is presented. Alternative methods of interface connection were used in order to investigate the performance of strengthened concrete columns. These connecting techniques involved roughening the surface of the original column, embedding steel dowels into the original column and a combination of these two techniques. The experimental program included three strengthened specimens, one original specimen (unstrengthened) and one as-built specimen (monolithic). The specimens represented half height full-scale old Greek Code (1950's) designed ground floor columns of a typical concrete frame building. The jackets of the strengthened specimens were constructed with shotcrete. All specimens were subjected to displacement controlled earthquake simulation loading. The seismic performance of the strengthened specimens is compared to both the original and the monolithic specimens. The comparison was performed in terms of strength, stiffness and hysteretic response. The results demonstrate the effectiveness of the strengthening methods and indicate that the proper construction of a jacket can improve the behaviour of the specimens up to a level comparable to monolithic behaviour. It was found that different methods of interface treatment could influence the failure mechanism and the crack patterns of the specimens. It was also found that the specimen that combined roughening with dowel placement performed the best and all strengthened columns were better at dissipating energy than the monolithic specimen.

공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션 (Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House)

  • 김주용;민만기;최영돈
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

Development of Optical Fiber-based Daylighting System with Uniform Illumination

  • Ullah, Irfan;Shin, Seoyong
    • Journal of the Optical Society of Korea
    • /
    • 제16권3호
    • /
    • pp.247-255
    • /
    • 2012
  • Daylighting has a very effective role in reducing power consumption and improving indoor environments in office buildings. Previously, it was not under consideration as a major source of renewable energy due to poor reliability in the design. Optical fiber as a transmission medium in the daylighting system demands uniform distribution of light to solve cost, heat, and efficiency issues. Therefore, this study focuses on the uniform distribution of sunlight through the fiber bundle and to the interior of the building. To this end, two efficient approaches for the fiber-based daylighting system are presented. The first approach consists of a parabolic mirror, and the second approach contains a Fresnel lens. Sunlight is captured, guided, and distributed through the concentrator, optical fibers, and lenses, respectively. At the capturing stage, uniform illumination solves the heat problem, which has critical importance in making the system cost-effective by introducing plastic optical fibers. The efficiency of the system is increased by collimated light, which helps to insert maximum light into the optical fibers. Furthermore, we find that the hybrid system of combining sunlight and light emitting diode light gives better illumination levels than that of traditional lighting systems. Simulation and experimental results have shown that the efficiency of the system is better than previous fiber-based daylighting systems.

공동주택에서 환기장치류 가동특성에 따른 실내공기질 변화특성에 관한 연구 (The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation)

  • 김석근;이정재
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.142-148
    • /
    • 2007
  • The purpose of this study is to suggest the effective ventilation strategies and control methods that can minimize energy cost maintaining acceptable IAQ level in apartment house. The effects of the air-cleaning and heat-recovery ventilation system on IAQ under various operating conditions are investigated based on the experimental and CFD analyzed results. The results can be summarized as follows. (1) When a ventilator is not operated, the concentration of several pollutants may highly show in the house even though environment-friendly building materials are applied. Therefore, a mechanical ventilation system is required to obtain proper ventilation. (2) The pollutant concentration is noticeably deceased under air-cleaning/ventilation mode of air-clinic system, however, pollutant of kitchen is stagnant, because fresh air is not carried into the kitchen. (3) When air-clinic system is only equipped at master bedroom and living room, the system does not effectively deliver fresh air throughout the whole house, and then high pollutant concentration is obtained in each room. In contrast the average pollutant concentration meets the guideline when air-clinic system is installed at each room. (4) The air-cleaning/ventilation mode significantly affects on room ventilation in comparison with ventilation mode only.

Dynamic intelligent control of composite buildings by using M-TMD and evolutionary algorithm

  • Chen, ZY;Meng, Yahui;Wang, Ruei-Yuan;Peng, Sheng-Hsiang;Yang, Yaoke;Chen, Timothy
    • Steel and Composite Structures
    • /
    • 제42권5호
    • /
    • pp.591-598
    • /
    • 2022
  • The article deals with the possibilities of vibration stimulation. Based on the stability analysis, a multi-scale approach with a modified whole-building model is implemented. The motion equation is configured for a controlled bridge with a MDOF (multiple dynamic degrees of freedom) Tuned Mass Damper (M-TMD) system, and a combination of welding, excitation, and control effects is used with its advanced packages and commercial software submodel. Because the design of high-performance and efficient structural systems has been of interest to practical engineers, systematic methods of structural and functional synthesis of control systems must be used in many applications. The smart method can be stabilized by properly controlling the high frequency injection limits. The simulation results illustrate that the multiple modeling method used is consistent with the accuracy and high computational efficiency. The M-TMD system, even with moderate reductions in critical pressure, can significantly suppress overall feedback on an unregulated design.

투명단열재가 적용된 축열벽 시스템의 최적구성 선정에 관한 연구 (A study on the Optimum Design Configuration of Passive Solar TI-wall system)

  • 김병수;윤종호;윤용진;백남춘
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.37-44
    • /
    • 2003
  • The aim of this study was to analyze the thermal performance through Test-Cell of TI-wall in domestic climate. This study was carried out as follows: 1) The TI-wall was studied for ability to reduce heat loss through the building envelope and analyzed to TIM properties. 2) Test models of TI-wall were designed through the investigation of previous paper and work, measured for winter and spring, and the thermal effects were analyzed. The type of the TIM used in test model is small-celled(diameter 4mm and thickness 50mm) capillary and cement brick(density $1500kg/m^3$) was used by thermal mass. 3) Test-cell of TI-wall was calibrated from measured data and the dynamic simulation program ESP-r 9.0. In these simulations, the measured climate conditions of TaeJon were used as outdoor conditions, and the simulation model of Test-cell was developed. 4) The sensitivity analysis is executed in various aspects with standard weather files and ESP-r 9.0, and then most suitable system of TI-wall are predicted. Finally, The suitable system of TI-wall was analysed according to sizes of air gap, kinds, thickness, and the surface absorption of therm wall. The result is following. In TI-wall, Concrete is better than cement brick, at that time the surface absorption is 95%, and the most efficient thickness is 250mm. As smaller of a air gap, as reducer of convection heat loss, it is efficient for heating energy. However, ensuring of a air gap at least more than 50mm is desirable for natural ventilation in Summer.

TRNOPT를 이용한 수직 지중열교환기 길이 산정 방법에 관한 연구 (Sizing of Vertical Borehole Heat Exchangers using TRNOPT)

  • 박승훈;이현수;장용성;김의종
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.402-407
    • /
    • 2016
  • Ground-coupled heat pump systems have been widely used, as they are regarded as a renewable energy source and ensure a high annual efficiency. Among the system components, borehole heat exchangers (BHE) play an important role in decreasing the entering water temperature (EWT) to heat pumps in the cooling season, and consequently improve the COP. The optimal sizing of the BHEs is crucial for a successful project. Other than the existing sizing methods, a simulation-based design tool is more applicable for modern complex geothermal systems, and it may also be useful since design and engineering works operate on the same platform. A simulation-based sizing method is proposed in this study using the well-known Duct STorage (DST) model in Trnsys. TRNOPT, the Trnsys optimization tool, is used to search for an optimal value of the length of BHEs under given ground loads and ground properties. The result shows that a maximum EWT of BHEs during a design period (10 years) successfully approaches the design EWT while providing an optimal BHE length. Compared to the existing design tool, very similar lengths are calculated by both methods with a small error of 1.07%.

무선 센서 엑츄에이터 네트워크에서의 시간지연을 고려한 노드 스케줄링 제어 기법 (A Node Scheduling Control Scheme with Time Delay Requirement in Wireless Sensor Actuator Networks)

  • 변희정
    • 인터넷정보학회논문지
    • /
    • 제17권5호
    • /
    • pp.17-23
    • /
    • 2016
  • 무선 센서 엑츄에이터 네트워크(WSAN) 시스템은 기존의 무선 센서 네트워크(WSN)에서 엑츄에이터 기능을 추가한 센서 노드들을 연결하여 망을 구성하는 시스템이다. 엑츄에이터는 센서 노드와 함께 작동하며, 재난구호, 군용 감시체계, 건강 모니터링 및 기반시설 보안 등의 여러 응용분야에 적용된다. 이러한 응용분야는 적시에 정확하게 작동하여 데이터를 신뢰성 있게 전달하는 능력이 요구된다. 생물학적으로 영감을 받은 모델링 기법은 개별적인 단순함을 유지하면서 동시에 강인성과 확장성, 적응성을 달성할 수 있는 기법으로 최근 상당한 관심을 받아오고 있다. 본 논문에서는 생물학적 메커니즘 중 전염병 전파 모델을 기반으로 이산 동적 모델을 제안하고 WSAN 시스템에 적용하고자 한다. 이를 위해 에너지 소모를 최소화하면서 동시에 시간지연 구속조건을 갖는 데이터 전파를 위한 노드 스케줄링 기법을 제안한다. 제안된 기법의 평형 상태 분석과 제어이론을 바탕으로 시스템의 안정성을 분석한 후 시뮬레이션 결과를 통해 요구 지연 시간을 만족하는 동시에 에너지 소모를 줄이는 성능을 검증한다.

주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가 (Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings)

  • 김덕성;김법전;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.

Improved Slow Charge Scheme for non-communication Electric Vehiclesby Predicting Charge Demand

  • Chang, Tae Uk;Ryu, Young Su;Kwon, Ki Won;Paik, Jong Ho
    • 인터넷정보학회논문지
    • /
    • 제21권5호
    • /
    • pp.39-48
    • /
    • 2020
  • Recently, the study and development of environment-friendly energy technique have increased in worldwide due to environmental pollution and energy resources problems. In vehicle industry, the development of electric vehicle(EV) is now on progress, and also, many other governments support the study and development and make an effort for EV to become widely available. In addition, though they strive to construct the EV infra such as a charge station for EV, the techniques related to managing charge demand and peak power are not enough. The standard of EV communication has been already established as ISO/IEC 15118, however, most of implemented EVs and EV charge stations do not support any communication between each of them. In this paper, an improved slow charge scheme for non-communication EVs is proposed and designed by using predicting charge demand. The proposed scheme consists of distributed charge model and charge demand prediction. The distributed charge model is designed to manage to distribute charge power depending on available charge power and charge demand. The charge demand prediction is designed to be used in the distributed charge model. The proposed scheme is based on the collected data which were from EV slow charge station in business building during the past 1 year. The system-level simulation results show that the waiting time of EV and the charge fee of the proposed scheme are better than those of the conventional scheme.