• Title/Summary/Keyword: Building Energy Saving Level

Search Result 47, Processing Time 0.038 seconds

Insulation Level Assessment on the Military Residential Facilities Considering the Investment Payback Period (투자회수기간을 고려한 군 주거시설의 단열수준 산정 연구)

  • Park, Young Jun;Meang, Joon Ho;Kim, Taehui;Kim, Sung Joong;Lee, Seung-Min;Son, Kiyoung
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • Purpose: This study, which is based on the investment payback periods, aims to suggest the proper insulation level which can be adapted to the Defense Military Facility Criteria regarding the military residential condominiums. For the energy performance simulation, it is required to collect the residential data regarding the military condominiums and climatic data concerning the regions they belongs to. The estimates through energy performance simulation are the regional heating loads and the heating transmission coefficients of building components. Method: With the heating loads, the annual heating cost saving per square meters is assessed. With the heating transmission coefficients of building components, the additional insulation installment cost per square meters is evaluated. With two outcomes, one as an annual value and the other as a present value, the investment payback period is calculated. Result: In result, it could be concluded that 55~70% insulation ratio can lead a superior residental environments as well as be contributed to the national policy associated with zero-energy buildings because the estimated investment payback period is shorter than the life span of the military residental condominiums. This upshot can be used as a foundation to enactment the Defense Military Facility Criteria associated with military residential condominiums.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

A Feasibility Study on the Benefit of Daylighting by LCC Analysis (LCC 기법을 통한 자연채광의 경제성 분석에 대한 연구)

  • Kim, Jeong Tai;Kim, Gon
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.3-10
    • /
    • 2006
  • As has been expected, economic factors are a major consideration in almost every decision in building design process. Assuming that improving a lighting system, existing or proposed, will reduce operating cost, what preliminary economic guidelines can be established to determine whether any proposed investment appears cost effective? In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. This paper aims to exemplify the benefit of daylighting in term of economic consideration. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The accumulated performance of electric and daylighting is figured out to declare the effective depth of daylight in the space. The analysis on the saving amount of lighting energy due to daylight has been undertaken in answer to the question, that is, several projects are being considered, which is the most desirable from the cost-effectiveness viewpoint. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control hardware.

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

The Study about Improvement of Neuro Energy Decreased by Energy Saving (에너지절감에 의해 감소되는 뉴로에너지의 증강에 관한 연구)

  • Kim, Myung-Ho;Kang, Dong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.715-721
    • /
    • 2018
  • This study examined energy saving and elevating the worker's neuro energy (comfort, concentration, physical, and psychological stability) by compensating for the unpleasant tactile sensation to stimulate auditory and olfactory senses and reduce energy consumption. The experiment was conducted in an environment test room under the test conditions of temperature $25[^{\circ}C]$, relative humidity 50[RH%], illumination 1,000[lux] and air current speed 0.02[m/sec] by stimulating the auditory senses with a 1/f change in rhythm and the olfactory senses with an aroma scent. The experiment utilized the method of EEG, which evaluates human body's psychological status via tactile means, and the method of the vibra image, which evaluates the learning abilities, HRV and human body's psychological status via non-tactile means. The subjects were selected as eight university students (four males and four females) in their 20s, the type that have high relative ${\alpha}$(8~13[Hz]) activation in occipital lobe, which brings the highest level of mind stability and concentration, who had no difficulty in physical activities. The subjects' posture and physical activity was fixed to 1met - when the subjects are seated and relaxing in a comfortable environment - and their clothes condition was standardized as 0.7clo. As a result, the sentimental and psychological stability and concentration were the highest in the multisensory stimulation of jasmine scent and change rhythm of an a=1.106 sound source. In addition, under this condition, the relative $M{\alpha}$ and relative $M{\beta}$ increased by 70.49[%] and 89.72[%], respectively; the HRT decreased by 39.09[%]; and the fatigue and tension/anxiety decreased by 36.85[%] and 15.54[%], respectively.

Numerical Analysis for the Effect of Ground and Groundwater Conditions on the Performance of Ground Source Heat Pump Systems (토양 및 지하수 조건이 지열공조시스템의 성능에 미치는 영향에 관한 수치 해석적 연구)

  • Nam, Yu-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.321-326
    • /
    • 2011
  • Recently, ground source heat pump (GSHP) systems have been introduced in many modem buildings which use the annually stable characteristic of underground temperature as one of the renewable energy uses. However, all of GSHP systems cannot achieve high level of energy efficiency and energy-saving, because their performance significantly depends on thermal properties of soil, the condition of groundwater, building loads, etc. In this research, the effect of thermal properties of soil on the performance of GSHP systems has been estimated by a numerical simulation which is coupled with ground heat and water transfer model, ground heat exchanger model and surface heat balance model. The thermal conductivity of soil, the type of soil and the velocity of groundwater flow were used as the calculation parameter in the simulation. A numerical model with a ground heat exchanger was used in the calculation and, their effect on the system performance was estimated through the sensitivity analysis with the developed simulation tool. In the result of simulation, it founds that the faster groundwater flow and the higher heat conductivity the ground has, the more heat exchange rate the system in the site can achieve.

Construction form and status analysis of intelligent type switching board of educational institution (교육기관 지능형 수배전반의 구성방식과 현황분석)

  • Choi, In-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.393-396
    • /
    • 2007
  • Recently one level higher intelligent switching board than established one by the application of intelligent building and digital system are being constructed. Therefore facility's high efficiency, high degree satisfaction, miniaturaization, standardization through application of communication technology and monitoring and controlling by computer system utilized by web-basis power control system and electric IT are practiced. Especially network must be constructed through unified IBS server that monitors every educational institute's switching boards in real time control system. And I intend to create methods to save energy and raise electricity quality by power demand prediction and remote-controled management and operation. In this thesis I intend to suggest measures of forming unified system through researching educational institute's ways of constructing switching board and status analysis and overcoming technical difficulties in user's side and saving and maintenance expense.

  • PDF

The Study on Excavation & Restoration Gu-dul in Young-dong (영동(永同)지역 전통(傳統)구들의 발굴(發掘) 및 복원(復原))

  • Cho, jung-kun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.8 no.1
    • /
    • pp.111-120
    • /
    • 2006
  • Our ancestor has accumulated inimitable a building system from experience. and they finally invented Gu-dul that heat the stone as a hitting system. The purpose of this study is to investigate and to write down the on Excavation & Restoration of Traditional Gu-dul in Young-dong. It was found that Gu-dul was the most suited for natural condition. That is wind, direction, earth level. As the results of analyzing the built- technque of traditional Gu- dul : 1) The Gu-dul type is lined, scattered, and mixed. 2) The hight of bank is 25-30cm, 3) The depth of Gaejari is 30-45cm, and The slope of that is gentle. 4) The slope of Gorae(a floor hitter) is 5 - 8%. (from the middle to the edge and from the lower part to the upper part) Therefore, For the practical application of future houses, it will be needed to develop the reasonable hitting system, and suggest to set up Gu-dul for our health and saving energy.

  • PDF

Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories - (BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 -)

  • Jun, Jae-Hong;Park, hye-Jin;Lee, Kweon-Hyung;Choo, Seoung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

An Environment-friendly Analysis of Hong-kong Environment-friendly Reuse Space (홍콩 친환경 재생공간의 친환경성 분석)

  • Kim, Sarah;Nam, Kyoung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.194-202
    • /
    • 2012
  • The purpose of this study is to extract environment-friendly planning elements to apply in Korea by putting together and reclassifying four foreign environment-friendly certification systems related to regeneration spaces - LEED in USA, CASBEE in Japan, BREEAM in England and BEAM in Hong Kong - and analyze and evaluate domestic and foreign spaces which were certified as Environment-friendly spaces in order to offer plan guidelines to raise awareness of the importance of environment-friendly elements in regeneration spaces and to encourage them. The concept and the characteristics of green building were studied through documentary survey. In addition, green certification system of the present domestic new spaces and foreign regeneration spaces was studied and assessment tools for indoor regenerated spaces-related green certification system were developed. With checklists which are developed in this study, level of going green of foreign spaces certified environment-friendly was assessed. Based on the results of this study, conclusions are as follows. As a result of case research of spaces-certified green of Hong-Kong's existing buildings with a developed checklist, application of general assessment part was all alike, but that of detailed assessment part was different. However, Hong Kong showed superiority in lighting energy saving, separate collection of recyclable domestic waste, recycling by-product and management. In addition, Hong Kong applied eco-friendly planning elements maintaining buildings in their condition as possible as it could with management, use of green program, replacement with high efficiency lighting, monitoring system, installation of recycling bins and energy saving by attaching reflective film.

  • PDF