• 제목/요약/키워드: Building Energy Saving Level

검색결과 47건 처리시간 0.026초

사무소 건물의 외피 리모델링에 따른 에너지절감효과 및 경제성 분석 (The Energy Saving Effect and Economic Assessment of Office Building according to the Building Envelope Remodeling)

  • 최선우;김지연;박효순;김준태
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.85-92
    • /
    • 2012
  • The Korean government has introduced building regulations with improved energy conservation measures, including higher insulation levels for building envelope. However, there are many existing buildings that tend to consume more energy for heating and cooling than new buildings, as they were built under the former regulations with relatively higher U-values of walls and glazing. In order to improve energy efficiency in existing buildings, green remodelling of building envelope and building services are required. For existing buildings, building services improvements have been achieved through energy service company(ESCO), but much attention has not been paid to building envelope improvements with various reasons, such as uncertainty of energy saving effect design issues and costs. The aim of this study is to evaluate the impact of building envelope improvements in a typical commercial building on its heating and cooling energy loads. The results show that the improvement of glazing with lower U-values has the highest energy saving effects, followed by wall, roof and floor, under the condition of same level of insulation improvements. However, high insulated glazing increased LCC because of higher initial investment costs.

공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석 (Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings)

  • 이한솔;김서훈;김종훈;김준태;장철용
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

패시브 디자인을 적용한 주택의 기밀성에 관한 실측 사례 연구 (The measurement study on the airtightness of dwellings based on the passive design)

  • 이태구;윤두영
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.13-20
    • /
    • 2013
  • Today, the world energy consumption in buildings occupies more than 30%. In our country, the energy consumption in buildings also occupies 25% of the entire national energy consumption. With the increasing demand of energy saving in architectural fields, there is a more interest in low-energy construction. For these low-energy housings, our country is planning to apply the energy-saving design standards at the level of passive houses in 2017. However, there is still a limitation in energy saving only with the standards on the performance of envelope in buildings. This means that unless a building is airtight even though it was well-insulated, cooling and heating energy consumption will increase due to the infiltration and leakage. Therefore, this study aims to make a comparative analysis of airtight performance by conducting a blower door test on the housings applied with passive designs, analyze the reasons why most houses fall short of the airtightness standards, and complement the airtightness problems in the inadequate parts of the buildings in order to save building energy.

초고층 주거건물의 에너지 성능 분석에 관한 연구 (A Study on the Analysis of Energy Performance of High-rise Residential Buildings)

  • 석호태;김장한;정만석
    • 한국주거학회논문집
    • /
    • 제15권4호
    • /
    • pp.35-43
    • /
    • 2004
  • The environment pollution is very important problem. Even at the field of architecture, a study about method of saving energy and constructing environment friendly building will have performed with activity. But trends of Korea housing market are changed that the height of building become more higher and the level of comfort going up. Therefore, these requirements force to increase the energy usage for indoor environmental controls. Thus, the purpose of this study is to reduce the heating and cooling energy requirements of High-rise Residential Buildings by the analysis of Energy Performance. From now on, we search improvement plan for the most efficient Energy Saving at present High-rise Residential Buildings.

지역별 기후에 따른 비주거 건축물 패시브 수준 단열기준 연구 (Study on Insulation Standards at Passive Level of Non-Residential Buildings by Regional Climate)

  • 김예원;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.51-58
    • /
    • 2017
  • This study proposes an appropriate level of insulation standards by region through annual heating energy requirements according to regional climate. The reference buildings out of non-residential buildings approved by the energy saving design standard for buildings were derived in the previous study, in which the annual heating energy requirements for each building were as follows when the insulation standard for building members in four regions (Pyeongchang, Seoul, Gwang-ju, and Jeju) suggested by the energy saving design standard for buildings: $29.8kWh/m^2$ in Pyeongchang, $17.5kWh/m^2$ in Seoul, $14.4kWh/m^2$ in Gwangju, and $16.7kWh/m^2$ in Jeju. To satisfy the passive level of insulation standards for these buildings, in case that roof/floor of buildings in Pyeongchang and Seoul was $0.2W/m^2K$, the minimum window thermal transmittance should satisfy $0.9W/m^2K$ and the minimum wall thermal transmittance should satisfy $0.1W/m^2K$ in the case of Pyeongchang. On the other hand, the minimum window thermal transmittance should satisfy $1.5W/m^2K$ and the minimum wall thermal transmittance should satisfy $0.14W/m^2K$ in the case of Seoul. For Jeju regions, the minimum wall thermal transmittance should satisfy $0.34W/m^2K$ to meet the passive level of buildings. Based on the above results, the thermal transmittance of each member by region should take the outdoor climate condition of the region into consideration to satisfy the passive level of buildings.

The audit method of cooling energy performance in office building using the Simple Linear Regression Analysis Model

  • Park, Jin-Young;Kim, Seo-Hoon;Jang, Cheol-Young;Kim, Jong-Hun;Lee, Seung-Bok
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.13-20
    • /
    • 2015
  • Purpose: In order to upgrade the energy performance of existing building, energy audit stage should be implemented first because it is useful method to find where the problems occur and know how much time and cost consumption for retrofit. In overseas researches, three levels of audit is proposed whereas there are no standards for audit in Korea. Besides, most studies use dynamic simulation in detail like audit level 3 even though the level 2 can save time and cost than level 3. Thus, this paper focused on audit level 2 and proposed the audit method with the simple linear regression analysis model. Method: Two parameters were considered for the simple regression analysis, which were the monthly electric use and the mean outdoor temperature data. The former is a dependent variable and the latter is a independent variable, and the building's energy performance profile was estimated from the regression analysis method. In this analysis, we found the abnormal point in cooling season and the more detailed analysis were conducted about the three heat source equipments. Result: Comparing with real and predicted models, the total consumption of predicted model was higher than real value as 23,608 kWh but it was the results that was reflected the compulsory control in 2013. Consequently, it was analyzed that the revised model could save the cooling energy as well as reduce peak electric use than before.

일본의 민생주택부문 에너지소비 및 절약기술관련 연구 개발동향 (Trend Study on Research for Energy Consumption and Saving Method in Residential Sector of Japan)

  • 유정현;유아사카즈히로;김용식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.819-824
    • /
    • 2008
  • Energy consumption in Korea and Japan has already progressed to high level. Especially, it will be important to take up the effort to achieve further energy savings in residential sector that has significant increase both nations. For this reason, research for energy consumption and saving method in residential sector compare Korea with Japan that of similar data to grasps the direction for energy savings. In addition for introduction of distributed energy system to residential sector, such as apartment house, the electricity and gas demand was simulated. To be more specific, several key characteristics were studied, such as housing type housing scale and width of common space.

  • PDF

District Energy Use Patterns and Potential Savings in the Built Environment: Case Study of Two Districts in Seoul, South Korea

  • Lee, Im Hack;Ahn, Yong Han;Park, Jinsoo;Kim, Shin Do
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권1호
    • /
    • pp.48-58
    • /
    • 2014
  • Energy efficiency is vital to improve energy security, environmental and social sustainability, and economic performance. Improved energy efficiency also mitigates climate change by lowering greenhouse gas (GHG) emissions. Buildings are the single largest industrial consumer of energy and are therefore key to understanding and analyzing energy consumption patterns and the opportunities for saving energy at the district level in urban environments. This study focused on two representative boroughs in the major metropolitan area of Seoul, South Korea as a case study: Gandong-gu, a typical residential district, and Jung-gu, a typical commercial district. The sources of the energy supplied to the boroughs were determined and consumption patterns in different industry sectors in Seoul used to identify current patterns of energy consumption. The study analyzed the energy consumption patterns for five different building categories and four different sectors in the building using a bottom-up energy modeling approach. Electricity and gas consumption patterns were recorded for different building categories and monthly ambient temperatures in the two boroughs. Finally, a logarithmic equation was developed to describe the correlation between commercial activity and cooling energy intensity in Jung-gu, the commercial district. Based on these results, recommendations are made regarding the current energy consumption patterns at the district level and government energy policies are suggested to reduce energy consumption and, hence, greenhouse gas emissions, in both commercial and residential buildings.

건물 에너지관리 실태 및 수준 평가 - 유지관리자를 대상으로 - (Questionnaire survey & Evaluation for Quality Level of Energy Management System in Buildings - survey for maintenance personnel -)

  • 곽노열;조승혁;권한솔;허정호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.112-119
    • /
    • 2008
  • In order to ensure building energy management at an appropriate level continuously, it is necessary to define clearly service work of energy management and to suggest evaluation index whether energy management in buildings is fit and improvement is needed or not. But, evaluation index of energy management level in buildings is not suggested yet in Korea. So, the purpose of this paper is to suggest evaluation index of energy management level in buildings, investigate the present state of Korean buildings and evaluate energy management levels. As a result of surveys of evaluation index of energy management, it is found that portion of level 1, which is the best level, is higher than any other level, level 2, level 3. And, throughout analysis, it is found that as total floor area is larger, evaluation index of energy management level is better, and, in order to increase energy management level, first of all, there is necessary for building's users to change understanding about energy saving and make a reform of national policy of energy management in buildings. Because there is rich relationship between items among evaluation index of this stuff and result value of evaluation index, evaluation index of energy management suggested in this study is available to evaluate energy management level in buildings.

  • PDF

오피스 건물에서 인접건물이 자연채광 성능에 미치는 영향 (A Study of the Daylighting Performance in Obstructed Office Building in Urban Area)

  • 박웅규;기현주;정찬울;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.101-108
    • /
    • 2014
  • The performance of the daylighting in buildings depends on building site and shape. As an energy saving design strategy, daylighting is a key issue in green building design. In this paper, the influence of the adjacent or obstructed building on daylighting performance of the office building in urban area was analyzed. A typical office building about 20 storeys with obstructed buildings has been modeled and simulated using Radiance. The parametric simulations have been performed to analyze the influence of the daylighting performance (illuminance, luminance) of the analyzed office. The results show that the possibility of the glare was decreased when the obstructed building is located in south, also the illuminance level was significantly decreased. When the obstructed building is located in north, the changes of the illuminance level and luminance possibility were somewhat small compared to the unobstructed condition. The daylighting performance of the analyzed building was most affected by the obstructed building in winter season.