• 제목/요약/키워드: Building Energy Rating System

검색결과 89건 처리시간 0.029초

LEED Healthcare에서 득점 현황 분석에 관한 연구 (The Analysis of Achieved Score earned by LEED Healthcare)

  • 강지은
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.7-14
    • /
    • 2019
  • Purpose: The purpose of this research is to find out week and strong aspects in LEED categories based on achieved scores earned by LEED-HC(Healthcare) v.2009. Methods: The LEED-HC scorecards of 88 healthcare projects are analyzed. The analysis are focused on relationship between achieved scores, LEED categories and achieved levels. This relationship was presented by graphs and charts. Results: 1) Compare to LEED-NC, in LEED-HC, sub-categories related to public health are added. The scores are added in Energy Atmosphere and Indoor Environmental Quality. 2) Achieve scores in Sustainable Site are high and one in Energy Atmosphere and Indoor Environmental Quality are low at all levels. 3) Scores which was lost in Energy Atmosphere are recovered in Material Resource and Sustainable Site in order to keep its level. 4) Since most of scores in Energy Atmosphere are under EAc1 Optimize energy performance sub-categories, it is important to achieve more score in Optimize Energy Performance Sub-Categories to gain a higher level. Even if LEED-HC has more score in Energy Atmosphere, this is a hard to achieve scores in that categories. It is important to review Energy Atmosphere categories and its points for improvement. Implications: This study will provide basic database in order to establish Korean green building rating system for hospital.

초고층 주거건축의 지속가능한 디자인 및 계획요소 특성에 관한 연구 -국내.외 지속가능한 건축물 인증사례를 중심으로- (A Study on the Characteristics of Sustainable Design and Planning Elemensts of High-Rise Residential Architecture -Focuse on certification examples of domestic and overseas sustainable buildings-)

  • 신성은;이상호;이성옥;김수암
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.217-222
    • /
    • 2009
  • This study is lately stand on the basis of the importance for global warming and environment and accept changes of the paradigm of the 21st century. also it is to start architecturial access that suggest to solutions about environment, energy and health problems in high-rise residential architecture that lately the importance for global warming and environment. Spacially since 1990, high-rise residential architecture has developed into increase rapidly, and nowdays, this has become one of the new residence type. but this have diverse problems. For this reason, this building faced neccessary to improve living space and obtain to eco-friendiness and sustainability. Therefore, this study is focused to environment-friendly architectural certification in Korea and other countries, aims to suggest planning and technical elements from this system. Through 11 cases of high-rise residential architecture certified sustainable certification system, this study drew out tendency and charateristics of main strategy elements. These analysis will express informations of current level and also suggest to direction for improvement in quality of high-rise residence.

  • PDF

공동주택 단위세대의 기기발열 특성 분석 및 추정모델 개발 (An Analysis on Characteristics and the Development of Estimation Model of Internal Heat Gain from Appliances in Apartment Units)

  • 이수진;진혜선;김성임;임한영;임재한;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제34권10호
    • /
    • pp.19-26
    • /
    • 2018
  • The purpose of this study was to analyze characteristics and to develop estimation model of IHG(Internal Heat Gain) from appliance in domestic apartment units. To do this, it was defined the source of IHG from appliance and the calculation method through the case study of international and domestic codes. And the equipment related datum such possession, usage or not, etc were collected through field survey in apartment units, and the appliances' electricity consumption were measured separately from overall electricity consumption. Annual electricity consumption value were calculated with field survey datum and appliances' electricity consumption measurement datum, and then IHG value was calculated by applying PHPP v9 method. And it was conducted correlation analysis between IHG value and the area for exclusive use, the number of occupants, and then the IHG from applianace estimation model was deducted with regression analysis. Finally, it was analyzed the present level and of the domestic code(The Building Energy Efficiency Rating System) comparing with the value of estimation model, and the various international codes(HERS, Building America, SAP).

Correlation Analysis between Median Household Income and LEED-Certified Public Transportation Access

  • Han, Hee Su;Kim, Boo-Young;Park, Young Jun;Son, Kiyoung
    • 한국건축시공학회지
    • /
    • 제14권3호
    • /
    • pp.266-272
    • /
    • 2014
  • The Leadership in Energy and Environmental Design (LEED) Green Building Rating System provides third-party verification for environmentally sustainable construction. But while LEED-certified buildings provide healthier work and living environments, Previous studies have shown that LEED certification does not provide any direct economic incentives to owners and developers. To address this issue, this study aims to investigate the economic benefits of LEED criteria. The objective of this study is to examine whether or not there is a significant correlation between median household income and the number of bus stops and light rail stations for a given parcel that meet LEED sustainable site criteria for public transportation access. The findings showed that the number of bus stops had a positive correlation with median household income, which means that more bus stops a given parcel had that met LEED criteria, the greater the median household income of a block group where the given parcel was located would be, though this positive correlation was very weak.

성능함수제어 알고리즘을 이용한 3상 4선식 하이브리드형 직렬능동전력필터 (Hybrid Series Active Power filter Based on Performance Function Theory for 3-Phase 4-wire System)

  • 김진선;신재화;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1096-1098
    • /
    • 2003
  • In this paper, the control algorithm and control methods for a combined system of shunt passive filter and series active filter in 3-phase 4-wire system are discussed. Moreover, the 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and odd multiples of $3^{rd}$($9^{th}$, $15^{th}$, etc.) are termed as triple and zero sequence components that do not cancel each other in the system neutral. As a result, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control scheme for a series hybrid active system. This series active power filter acts not only as a harmonic compensator but also as a harmonic isolator. Hence the required rating of the series active filter is much smaller than that of a conventional shunt active filter. However, the performance of the combined system is greatly influenced by the filtering algorithm employed in the active power filter. This paper proposes a series active power filter scheme based on performance function. Some experiments was executed and experimental results from a prototype active power filter confirm the suitability of the proposed approach.

  • PDF

3상 4선식 하이브리드 형 직렬 능동전력필터에 대한 새로운 성능함수 제어 이론 (A New Performance Function-Based Control Strategy for Hybrid Series Active Power Filter in Three-Phase Four-Wire Systems)

  • 신재화;김진선;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권11호
    • /
    • pp.563-571
    • /
    • 2003
  • In this paper, the control algorithm and control method for a combined system of shunt passive filter and series active filter in 3-phase 4-wire system are discussed. Moreover, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3th harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts may directly influence its compensation characteristics. Hence, the advantage of this control algorithm is direct extraction of compensation voltage reference and the required rating of the series active filter is much smaller than that of a conventional shunt active filter. Some experiments were executed and experimental results from a prototype active power filter confirm the suitability of the proposed approach.

LEED-Healthcare 세부항목의 평균득점률을 통한 병원의 친환경성 분석 (Analysis of Sustainability of Hospital Based on Average Achieved Rate in LEED-HC Credits)

  • 강지은
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권1호
    • /
    • pp.29-37
    • /
    • 2020
  • Purpose: The purpose of the research is to find difficulty levels of LEED credits in each LEED level based on credits achievement in order to find important of LEED-HC credits to gain LEED-HC. Methods: The individual credits of LEED-HC v.2009 scorecards from USGBC website are analyzed. With achieved scores rate of LEED credits per each Level, all credits are reassembled in 4 different ranges (A~D); easy (A), easy-moderate (B), moderate-hard (C) and hard (D) to achieve scores. Results: 1) Achieved point rate in LEED-HC specific credits are low. These credits need to be reviewed carefully. 2) In 88 projects, 37 projects are gained Silver level which is more than projects in certification level. In order to encourage to gain LEED-HC level, Average Achieved rate to earn Certificate level needs to be risen. 3) Credits in range D rarely affect to gain platinum level. EAc1 (24 points) are critical to gain Silver and Gold level. However, EAc1 points are not effective to achieve Certificate level. Implications: This research will provide a fundamental back data to set up Korean Green building rating system for Healthcare.

Series Active Power Filters to Compensate Harmonics and Reactive Power with the Direct Compensating Voltage Extraction Method in Three-Phase Four-Wire Systems

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.691-699
    • /
    • 2009
  • This paper presents the analysis of series active power filter for reactive power compensation, load balancing, harmonic elimination, and neutral current eradication in three-phase four-wire power systems. Generally, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3rd harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts directly influence its compensation characteristics. Hence, the advantage of this control algorithm is the direct extraction of compensation voltage reference without phase transformations and multiplying harmonic current value by gain and the required rating of the series active filter is much smaller than that of a conventional shunt active power filter. In order to show the effectiveness of the proposed control algorithm, experiments have been carried out.

염해 환경하의 철근콘크리트 구조물의 친환경 내구설계 시스템 개발에 관한 연구 (A Study on the Development of Sustainable Durability Design System for Reinforced Concrete Structure under Chloride Attack Environments)

  • 김낙현;노승준;태성호
    • KIEAE Journal
    • /
    • 제11권4호
    • /
    • pp.87-94
    • /
    • 2011
  • This study was suggested to develop sustainable durability design system and proposed the plan to evaluate design conditions that meet the intended service life and $LCCO_{2}$ reduction level of reinforced concrete structure easily from the early design stage. For that the W/B and covering depth of the concrete structure were calculated through calculation of service life based on standard specification expression and the quantitative reduction rate of the vertical member of reinforced concrete structure by the calculated W/B was applied. Life cycle of building classified into construction stage, operation stage, maintenance stage, and demolition/disposal stage and the method of $CO_{2}$ evaluation of each stage was proposed. For construction stage, the major construction materials that take up over 80% $CO_{2}$ emitting during building construction were selected and the $CO_{2}$ evaluation method for 5 standard apartment houses was proposed. Also, for operation stage, $CO_{2}$ emission was calculated through calculation of heating load by energy efficiency rating certification system. For maintenance stage, $CO_{2}$ emission was calculated using concept of re-construction by life and for demolition/disposal stage was calculated with the use of construction standard estimate. As a result of the case study by such evaluation methods, 80 years of service life and 17 specifications of sustainable durability design that meet the 40% intended $LCCO_{2}$ reduction level were deduced. The Maximum $LCCO_{2}$ reduction rate was analyzed by 47.2%.