• 제목/요약/키워드: Building Control System

검색결과 1,618건 처리시간 0.031초

지반-구조물 상호작용을 고려한 복합제어시스템의 최적설계 (Optimal Design of Integrated Control System Considering Soil-Structure Interaction)

  • 박관순;박장호
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.57-64
    • /
    • 2012
  • For the vibration control of earthquake-excited buildings, an optimal design method of integrated control system considering soil-structure interaction is studied in this paper. Interaction between soils and the base of the building is simply modeled as lumped parameters and equations of motion are derived. The equations of motion are transformed into the state space equations and the probabilistic excitations such as Kanai-Tajumi power spectral density function is introduced. Then an optimization problem is formulated as finding hybrid or integrated control systems which minimizes the stochastic responses of the building structure for given constraints. In order to investigate the feasibility of the optimization method, an example design and numerical simulations are performed with tenstory building. Finally, numerical results are compared with a conventional design case that soil-structure interaction is not considered.

LQG 보상기를 이용한 건물의 진동제어 실험 (Experimental Study on the Vibration Control for Building Structures using LQG Compensator)

  • 민경원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.202-216
    • /
    • 1999
  • To control the motion of building structures under earthquakes their response should be measured first by various sensors and transformed into the control forces using some control algorithms. Of many control algorithms linear quadratic control is widely used as it is easy to implement and analyze. However the algorithms has the disadvantage that it needs the real-time measurements of all state variables(i.e, building's displacements and velocities) which are difficult to achieve for the building structures under earthquakes. Thus the practical algorithms employing output feedback are developed. In this paper LQG algorithm is used for the control of the building model with an active mass driver. The building's acceleration is used to obtain the control gain and the Kalman filter gain. The LQG control strategy is verified with the experimental study on the one-storybuilding model equipped with the active mass driver. This paper demonstrates experimentally the efficacy of the LQG algorithm based on the active mass driver system in reducing the response of seismically excited buildings.

  • PDF

빌딩시설 제어시스템용 안전한 망간 자료전송 방안 (Secure Data Transmission Scheme between Network for Building Facilities Control System)

  • 조인준
    • 한국콘텐츠학회논문지
    • /
    • 제18권8호
    • /
    • pp.102-108
    • /
    • 2018
  • 비 보안영역의 외부인터넷과 보안영역의 내부업무망간에 적용된 기존의 망간 자료전송기술을 빌딩시설관리 SCADA시스템 제어망에 그대로 적용할 경우에 다양한 문제들이 도출된다. 기존의 망간 자료전송기술은 모든 데이터를 대상으로 블랙리스트 기반의 보안기법이 적용되기 때문에 고 복잡성 및 고 비용이 수반된다. 하지만, 빌딩시설관리 SCADA제어시스템에서 유통되는 데이터의 특성은 소수의 정형적인 제어 데이터가 반복성과 주기성을 갖기 때문에 이를 대상으로 화이트리스트 기반의 보안기법 적용이 가능하다. 이를 통해서 망간 자료전송에 적용된 보안기술이 단순화되어 저 비용으로 빌딩시설관리 SCADA시스템 제어망 구축이 가능하다. 본 논문에서는 이러한 문제점들을 정리하고 이를 해결하는 방안을 제시하여 빌딩시설관리 SCADA제어시스템에 특화된 빌딩 제어망 구축방안을 제안하였다.

Building Energy Management System Coupling with Renewable Energy System

  • Oh, Jin-Seok
    • 한국항해항만학회지
    • /
    • 제34권9호
    • /
    • pp.705-709
    • /
    • 2010
  • Buildings nowadays are increasingly expected to need higher and more economic performance requirements. Energy consumption in buildings accounts for over 30% of total energy use. The Building Energy Management System (BEMS) and renewable energy (RE) technologies are considered as a potential measure to improve energy efficiency and reduce use of grid-power. It is, however, a challenge to utilise the intermittent energy supply of RE in building energy systems. This paper presents an experimental study on a RE-embedded BEMS. A control algorithm for the RE-embedded BEMS was designed to maximise the utilisation of RE and eventually to reduce electrical utility bill. The proposed system is tested at a laboratorial chamber with an air conditioner, fan and heater. The contribution of RE in building energy system is discussed to this end.

중앙냉난방시스템의 EMS 복합제어 효과 분석에 관한 시뮬레이션 연구 (A Simulation Study on Effect Analysis of EMS Combined Control of Central Cooling and Heating System )

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.33-44
    • /
    • 2022
  • In this study, we analyze the existing heating and cooling operation method for an office-type complex building with a central heating and cooling system, and examine the effects of applying various EMS that can be applied according to the load size to save energy in the building. For this purpose, simulation analysis was performed. As a control method, reset control of chilled water, hot water, cooling water and supply air temperatures, optimal start/stop of heat source, and number of heat source control were applied according to the load size, and energy consumption was analyzed accordingly. In addition, when all of these control methods were applied, the overlapping energy saving effect was finally confirmed. As a result, it was possible to confirm the energy saving effect when EMS for reset control and heat source control were applied compared to the existing control method of the heating and cooling system, and the effect for the case of using all these control methods in combination was also confirmed.

중앙난방시스템의 온라인 최적제어기법에 관한 연구 (On-line Optimal Control Technology for Central Heating System)

  • 안병천;최상곤;조성환
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.140-146
    • /
    • 2005
  • The on-line optimal control algorithm for central heating system has been researched for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as indoor heating load and outdoor temperature variation. This study has been done by using TRNSYS Program in order to analyze the central heating system. The optimal control algorithm shows good energy Performances in comparison with the conventional one.

퍼지 제어법과 HMI를 이용한 축사용 스마트팜 환경 제어기 설계 (Design of Smartfarm Environment Controller Using Fuzzy Control Method and Human Machine Interface for Livestock Building)

  • 이병로;이주원
    • 융합신호처리학회논문지
    • /
    • 제23권3호
    • /
    • pp.129-136
    • /
    • 2022
  • 스마트 축사 시스템에서 가장 중요한 부분은 내·외부 대기환경 변화에도 가축이 고품질로 성장할 수 있도록 사육환경을 유지하는 것이다. 특히 여름과 겨울에는 여러 질병이 발생하기 때문에 축사환경에서 온·습도 유지가 매우 중요하다. 이러한 환경을 관리하기 위해 축사용 스마트 시스템이 도입되고 있으나 매우 고가이다. 본 연구에서는 퍼지제어와 HMI를 기반한 저가의 시스템 설계와 제어 방법을 제안한다. 제안된 시스템의 성능을 평가하기 위해 여름철과 겨울철의 대기환경 조건을 주어 시뮬레이션 실험하였으며, 그 결과 가축이 받은 온습도 스트레스를 최소화하는 성능을 보였다. 그리고 실제의 축사에 적용했을 때도 제안된 시스템은 외부대기 환경변화에도 안정적인 제어성능을 보였다. 본 연구에서 제안한 기법이 스마트팜 제어기로 적용된다면, 축사 환경관리에 있어 효과적일 것이다.

중앙 냉방시스템에 대한 외기보상제어의 절약 성능에 관한 실험적 연구 (Experimental Study on Energy Saving Performance of Outdoor Temperature Reset Control Strategy for Central Cooling System)

  • 김동철;송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.30-36
    • /
    • 2011
  • In this study, energy saving performance of outdoor temperature reset control strategy for central cooling system is researched by experiments. Outdoor temperature reset control is the control method to change indoor air set temperature according to outdoor air temperature change. The range of indoor air set temperature is represented by the comfort temperature range of indoor air temperature offered from ASHRAE and indoor air set temperature is programmed between $22^{\circ}C$ and $27^{\circ}C$ by outdoor air temperature $20^{\circ}C{\sim}32^{\circ}C$ in summer. As a result of applying outdoor temperature reset control to central cooling system, the suggested control method shows better performances of energy savings than the conventional method which indoor temperature maintains constantly.

화재시 열유동장의 수치해석에 대한 평가 연구 (ASSESSMENT ON NUMERICAL ANALYSIS OF THERMAL FLOW INDUCED BY FIRE)

  • 김정엽
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.156-160
    • /
    • 2011
  • As building becomes larger, taller and more complex due to industrialization and urbanization, it tends to be vulnerable to fire and establishment of effective measures for fire safety is demanded. Especially the fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. To design and operate the smoke control system success folly, it is necessary to analyze and predict precisely the thermoflow induced by fire in building. The unsteady three-dimensional analysis of thermoflow induced by fire with diverse variables such as building structure, fire conditions and smoke control facilities can be effectively carried out with numerical method In this study, using the FDS(Fire Dynamics Simulation) program that spreads widely as the analysis tool for thermoflow of fire, the analysis of thermoflow in partition of building induced by fire and comparison with the experimental results for assessment of numerical analysis are presented.

  • PDF

스카이브릿지를 이용한 RC 주거용 건물의 진동제어 (Vibration Control of RC Residential Building Structure Using Sky-Bridge)

  • 안상경;오정근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.450-453
    • /
    • 2006
  • Coupling adjacent building with supplemental damping devices is a developing method of reduced structural response due to wind and seismic excitations. The philosophy is to allow structures, vibrating at different frequencies, to exert control forces upon one another to reduce the overall responses of the system. This paper studies the effect of installing vibration control devices of two high rise building structures(49 stories and 42 stories) connected by sky-bridge. According to the analysis results the use of sky-bridge can be effective in increasing damping ratio of the system.

  • PDF