• Title/Summary/Keyword: Building Condition

Search Result 1,918, Processing Time 0.03 seconds

격납건물 텐던갤러리 벽체의 온도응력에 대한 연구 (A Study on Thermal Stress in T/G Wall of Containment Building)

  • 김진근;양은익;박영진;송영철;방기성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.193-198
    • /
    • 1998
  • In this study, the change of concrete temperature, strain and thermal stress were measured by using the embedded type concrete gauges in tendon gallery wall of containment building. A finite element analysis was performed to clarify the thermal behavior of concrete. The analytic and test results were investigated to improve the validity of analytic method. According to the test results, concrete temperature, strain and thermal stress were strongly affected by measuring point and environment condition of member. And the thermal stress was developed in the member which was not demoulded at early ages. This is caused by the change of internal temperature and restrained condition. A finite element effectively interpreted the test results by estimating the concrete properties and the site condition.

  • PDF

바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가 (Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System)

  • 김세환;박종일
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

수축저감제 및 팽창재를 혼입한 HPC 충전용 콘크리트의 건조수축 특성 검토 (Study on Drying Shrinkage Properties of HPC Infilled Concrete Mixing Shrinkage Reducing Agent and Expansive Agent)

  • 박지웅;지우람;신기돈;고산;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.9-10
    • /
    • 2017
  • In case of the concrete is poured into the HPC(Hollow Precast Concrete) column, the shrinkage condition of the HPC surface and the infilled concrete may be different, causing an interfacial space and deteriorating the integration performance. In this study, manufacturing HPC column mold and and the drying shrinkage properties with the charging concrete were examined. As a result, case of the shrinkage reducing agent showed the best drying shrinkage reduction effect. In the case of the expansive agent, the length change was lower than that of plain, but the difference from the shrinkage reducing agent was large, so it is considered that mixing condition of expansion mixing condition should be improved.

  • PDF

800℃ 조건에서의 시멘트 경화체의 균열 특성 (Cracking Behavior of Cement and Concrete Damaged by High Temperature of 800℃)

  • 지우람;박지웅;신기돈;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.26-27
    • /
    • 2017
  • In this study, the cracking characteristics of cured pastes at 800℃ were investigated by X-ray CT. The test specimens were fabricated with and without aggregate, and the heating rate condition was applied at rapid heating (10.0℃/min). It is considered that the rapid heating condition does not cause a temperature gradient phenomenon because the temperature difference between the surface and the center of the sample is small due to a low heating rate unlike an actual fire. The cracking condition of the specimens without aggregate was more severe than that of specimens with aggregate.

  • PDF

수분증발조건 및 폴리믹스섬유 혼입에 따른 고강도콘크리트의 수축특성 (Shrinkage Properties of High Strength Concrete according to Poly mix Fiber and Moisture Evaporation Condition)

  • 함은영;김규용;구경모;남정수;김홍섭;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.289-290
    • /
    • 2012
  • In this study, it was evaluated about shrinkage properties of high strength concrete according to poly mix fiber and moisture evaporation condition. As a results, When concrete was mixed with poly mix fiber of spalling control, it reduced effect of shrinkage independent of the evaporation conditions of unsealed and sealed.

  • PDF

매트기초의 온도균열에 미치는 시공조건의 영향에 관한 연구 (A Study on the Effect of the Construction Conditions on a Thermal Crack of Mat Foundation)

  • 이도범;김효락;최일호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.1-4
    • /
    • 2003
  • Recently, a structure has been larger and higher under the improvement of construction technique. So, a mass concrete constructions that a mat foundation thickness of structure is over 80cm have been many. Also, because of the reason of high strength of concrete, the matter of thermal crack have become an important task to be solved absolutely. tn a cause of a thermal crack occurrence, there are material used, mixture of concrete, construction condition and so forth. In this study, we executed temperature and stress analysis of mat foundation to know the effect of the construction condition on a thermal crack of mat foundation. And we evaluated quantitatively about the occurrence possibility of thermal crack using the hydration heat analysis program. By using of this analysis technique, we will can control skilfully the quality of a mat foundation in advance.

  • PDF

링형 강관 구속 조건에 의한 콘크리트의 수증기압력과 구속응력 평가 (Evaluation on Water Vapor Pressure and Restrained Stress of Concrete by Ring-Type Restrained Condition)

  • 김도연;김규용;이상규;손민재;백재욱;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.27-28
    • /
    • 2018
  • In this study, water vapor pressure and restrained stress were evaluated by ring-type restrained condition for compressive strength 60 and 80MPa concrete. Experimental results show that the 80MPa concrete has higher water vapor pressure and restraint stress than the 60MPa concrete, resulting in spalling occurrence. It is because, the higher the compressive strength of the concrete, the more dense the internal structure is formed.

  • PDF

급속분리커플링으로 연결된 에어컨의 운전성능에 관한 실험적 연구 (A Study on Performance of Air-condition Linked by Quick Disconnect Coupling)

  • 조수;이수열;성욱주;박희문;심경종;김우승
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.551-556
    • /
    • 2008
  • This study analyzed operation characteristics of air-condition piping is made by quick disconnect coupling. Air-conditioning consists of central compressor 3HP capacity and R22 refrigerant. We experimented with two operation cycles of air-condition under the same environment; one is with quick disconnect coupling. The other is without quick disconnect coupling. As a result, we can observe whether the condensation temperature of former increased by about 3-5. Furthermore, COP decreased by about 10%.

  • PDF

RC조 구조물의 최적 음극방식 조건 설정을 위한 함수율의 영향에 대한 평가 (Effect of Moisture on the Current Density for Optimized Cathodic Protection Condition in RC Structures)

  • 박동천;조규환;안재철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2013
  • Steel corrosion is the most serious problem in RC structures. Even though patch repair method is normally applied in repair system, the effectiveness is not enough. Cathodic protection in active repair method to deteriorated RC structures. FEM model was developed to simulate the optimized cathodic protection condition. Iro oxidation, hydrogen evolution and oxygen reduction were considered to expect current distribution. Moisture content in concrete which can affect the electrolyte conductivity was used as initial condition.

  • PDF

한중 환경에서 알루미늄 폼 내부 철근의 직경변화에 따른 온도 특성 (Temperature History of Inner-form and Re-bars in Aluminum Concrete form During a Cold Weather Condition)

  • 정상운;김경훈;허영선;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.113-114
    • /
    • 2013
  • This study is to investigate the effect of the diameter of reinforcement bars located in an aluminum-form on the temperature histories of the re-bars before placing concrete during a cold weather condition. The diameters of reinforcement bars with 13 mm, 19 mm, 25 mm and 32 mm were prepared for the experimental tests. Results showed that the larger the size of the diameter of the bars, the higher were the temperature drop. However, this study found that its effect on the temperature drop of the bars was insignificant.

  • PDF