• 제목/요약/키워드: Building Condition

검색결과 1,922건 처리시간 0.026초

서원건축 강학공간에서 공간조건에 따른 강당의 평면형태 및 창호시스템의 변화에 관한 연구 (A Study on the Change of the Floor Plan and the Window & Door System of Kangdang according to the Space Condition in Education Area of Seowon Architecture)

  • 김은중
    • 한국실내디자인학회논문집
    • /
    • 제17권1호
    • /
    • pp.155-161
    • /
    • 2008
  • In Seowon architecture, there are four kinds of space conditions according to the site plan and the figure of education area. The education area has three main buildings such as Kangdang, Dongjae, Seojae. In case Kangdan locates in front of Dongjae and Seojae(so called Junkangdang-Hoojaesa), but in another case Dongjae and Seojae locates in front of Kangdang(so called Junjaesa-Hookangdang). This four space conditions affect to decide the floor plan and the window & door system of Kangdang. In Junjaesa-Hookangdang type, the front and rear wall has more open system than in Junkangdang-Hoojaesa type. In Junjaesa-Hookangdang type the direction of Kangdang is absolutely open to front education area, but in Junkangdang-Hoojaesa type the direction of Kangdang is absolutely open to rear education area. These floor plan aims at making up education area more closely. In window & door system the rear parts of Junjaesa-Hookangdang type have generally opaque system such as Golpanmoon or Panjangmoon, but Junkangdang-Hoojaesa type breaks this rule in order to emphasize front facade of building.

양생온도 변화 및 버블시트 두께변화에 따른 콘크리트의 온도이력특성 (Temperature History of Concrete Corresponding to Various Bubble Sheets Layer and Curing Temperature)

  • 홍석민;백대현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.21-25
    • /
    • 2008
  • In this paper, the temperature history and the strength development of concrete corresponded to various bubble sheets layer and curing temperature. Based on the results, In case of the test temperature of -5℃, concrete subject in the exposure condition, result in a frost damage at initial stage by a fall of below zero temperature. In case of the combination of PE film and non woven fabric was after 36 hour, and combination of bubble sheet over double, a tremendous insulating effect of bubble sheet over double is confirmed due to the temperature of concrete fall of below zero temperature after 60 hours. Meanwhile, regarding the -15℃ of temperature, special measure for insulation curing is necessary to secure stability against early frost damage because frost damage was not affected by the lapping thickness of bubble sheet subjected to severe cold weather condition.

  • PDF

양생조건에 따른 경량기포콘크리트의 특성 (Properties of Light Weight Foamed Concrete According to Curing Condition)

  • 신상철;최지호;홍성록;김지호;정지용;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.237-239
    • /
    • 2011
  • This study was performed to investigate the influence of curing temperature on the properties of light weight foamed concrete, manufactured on-site construction according to the various experimental factor such as temperature of material, curing temperature in air(5, 10, 20℃), curing time in air(5, 10, 15hour), and target density of hardened state(0.8, 1.2t/㎥). As a result, the influence of the curing temperature on various properties of foamed concrete is greater than curing time. When increasing temperature and time in air curing, progress of hydration is fast and compressive strength is increasing more and more. However, when considering the productivity, minimum curing time is required 15hours at 5℃, 10hours at 10℃, and 5hours at 20℃. If this condition is not required, there is some crack due to volume expansion on the surface of light weight foamed concrete.

  • PDF

Wind induced pressure on 'Y' plan shape tall building

  • Mukherjee, Sourav;Chakraborty, Souvik;Dalui, Sujit Kumar;Ahuja, Ashok Kumar
    • Wind and Structures
    • /
    • 제19권5호
    • /
    • pp.523-540
    • /
    • 2014
  • This paper presents a comprehensive study of pressure developed on different faces of a 'Y' plan shape tall building using both numerical and experimental means. The experiment has been conducted in boundary layer wind tunnel located at Indian Institute of Technology Roorkee, India for flow condition corresponding to terrain category II of IS:875 (Part 3) - 1987, at a mean wind velocity of 10 m/s. Numerical study has been carried out under similar condition using computational fluid dynamics (CFD) package of ANSYS, namely ANSYS CFX. Two turbulence models, viz., $k-{\varepsilon}$ and Shear Stress Transport (SST) have been used. Good conformity among the numerical and experimental results have been observed with SST model yielding results of higher magnitude. Peculiar pressure distribution on certain faces has been observed due to interference effect. Furthermore, flow pattern around the model has also been studied to explain the phenomenon occurring around the model.

배압에 따른 에어커튼형 냉동용 전시케이스의 성능변화 (Performance Variation of the Refrigerated Display Case with Air Curtain in Accordance with Back Pressure Condition)

  • 성순경;안교철
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.578-584
    • /
    • 2013
  • Vertical open display cases are widely used in shopping malls, supermarkets, or retail stores to sell frozen and refrigerated products. Open display cases use air curtains to maintain a reasonable temperature within the storage space, prevent insects from breaking in, and reduce energy usage. In this research, computational fluid dynamics was used to find the optimal condition for reducing energy by considering various conditions such as discharge speed or temperature of air curtains. Results of the study showed that the amount of energy consumed in the display cabinet is influenced by the discharge speed and temperature of the slots installed on the upper area and the amount of air supplied to the storage area inside the shelf. This shows that the amount of discharged air supplied from the storage area influences the formation of air curtain and also the amount of energy consumption. As a result of this study, we learned that the amount of energy used can be reduced by increasing the amount of discharged air within the storage area and enhancing back pressure.

환경문제에서의 재활용 행동 증진을 위한 행동분석적 실험 연구 - 환경적 변화와 프롬트의 효과를 중심으로- (A behavioral approach to increase recycling behavior: An examinination of effect of environmental alteration and prompts)

  • 오세진;양병화;현보성;황혜연
    • 한국환경교육학회지:환경교육
    • /
    • 제14권1호
    • /
    • pp.19-31
    • /
    • 2001
  • This study examined the effect of environmental alteration and prompts on recycling behavior. An A-B-BC with a control condition design was employed. Subjects in this study were college students, professors, and employees at a university building. After a baseline phase, environmental alteration was I effect in the next phase and both environmental alteration and prompts were in effect in the final phase for the control condition. The environmental alteration consisted of providing four separation containers for the paper cups, cans recyclable paper, and the disposable on each floor in the building. The prompts consisted of providing the information about the importance of environmental preservation and how to separate the materials in the appropriate containers using an information board and pamphlets. The dependent variables were (1) the number of cans collected in can container, (2) the number of paper cups collected in cup container, (3) the rate of correct separation of cans, (4) the rate of correct separation of paper cups, and (5) the weight of disposable. The rates of correct separations of cans and paper cups were obtained by calculating the percentage of thenumber of recyclable cans and paper cups in the corresponding containers. The results indicated that environmental alteration had positive effects on all the dependent variables. Also, when the prompts were added to the environmental alteration, the incremental effect of the prompts was demonstrated. The implications and limitations of theses findings were discussed and the direction of future studies was also proposed.

  • PDF

시멘트계 결합재로서 레미콘 슬러지의 재활용 방안에 관한 기초적 연구 (The Fundamental Study on Reusing Method of Ready-Mixed Concrete Sludge as Cement Binder)

  • 박진섭;서경호;김효열;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.21-26
    • /
    • 2004
  • This study deals with the Hydrated Ability of the Ready-Mixed Concrete's Sludge which is the recycling technology of that sludge. The experiment gathers sludge from Ready-mixed factory. shatters these into pieces in dry condition and understands the differences between current using Portland cement. And then. this examines the possibility of the recycle as a bonding agent through the Compressive Strength and considers the recovery of the hydration. This experiment concludes the same Chemical Composition with the normal Portland cement. while. under the appropriate procedure in hydration recovery. this sludge can be used as the bonding agent in cement. The chemical composition of solid Remicon sludge shows that it has 1.8 times $SiO_2$ than the normal Portland cement. meaning lots of aggregate in Remicon sludge. Also. the specific gravity of Remicon sluge increases with the rise of Baking Temperature and has no difference between 2.77 and 2.94. The mortar flow used for combining the baking material of Remicon sludge does was not changed and is the highest between $750^{\circ}C{\cdot}120min\;and\;800^{\circ}C{\cdot}180min$. Additionally. the Compressive Strength increases with the age, certifying the same Hydrated Ability like cement and the best condition for hydration is $750^{\circ}C{\cdot}120min.$

  • PDF

가열속도에 따른 콘크리트 내부의 수분이동이 폭렬발생에 미치는 영향 (Effect of Moisture Migration in Concrete with Hating Rate on Concrete Spalling)

  • 최경철;김규용;남정수;김홍섭;윤민호;황의철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.246-247
    • /
    • 2017
  • In this study, it reviewed the effect of moisture migration in concrete with heating rate on concrete spalling. Concrete specimens with compressive strength 30MPa and 110MPa are used and its size is □100×100×h200mm. And, two kinds of heating rate are set such as IS0 834 and 1℃/min. As a result, in the concrete specimen exposed to ISO 834 standard heating condition, moisture could migrate through pore network and surface concrete pieces fall out by generating moisture clog near the surface in 110MPa concrete specimen. Meanwhile, In the case of concrete specimens exposed to 1℃/min. heating condition, it is appeared that moisture could not migrate because temperature is distributed uniformly. Therefore, surface spalling is not occurred with low heating rate. However, in the case of 110MPa concrete specimen is exploded even though it heated by low heating rate.

  • PDF

기상청 통계자료기반 기후요소에 의한 작업불능일 산정 - 청주지역을 중심으로 - (Estimation of Non Working Day Corresponding to Statistical Data of Korea Meteorological Administration - Focused on Cheonju -)

  • 백대현;정웅선;박인범;송승헌;백병훈;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.141-145
    • /
    • 2008
  • In this paper, non working day for the construction project in Cheongju region considering weather condition for 30 years from 1971 to 2000 and 10 years from 1991 to 2000 as statistical periods was estimated. In Cheongju region, there was no remarkable difference between them because non working day for outside and half outside work was 157days and for interior work 144days at statistics for 30 years., and utside and half outside work was 159days and for interior work 142days at statistics for 10 years.. However, non working day due to high temperature is slightly increased, and non working day due to cold weather is slightly decreased in the case that the recent statistical data was used caused by global warming. Non working day due to rainfall was 23 days at statistics for 30 years, and it was 28 days at statistics for 10 years.

  • PDF

타의 종류에 따른 컨테이너선의 조종성능 특성 연구 (Experimental Study on the Variation of Maneuvering Characteristics of Container Ship with Rudder Type)

  • 김연규;김선영;김성표;이석원
    • 대한조선학회논문집
    • /
    • 제41권5호
    • /
    • pp.28-33
    • /
    • 2004
  • Generally Horn-type rudders have been used for single propeller and single rudder system. The reason is that the rudder torques of Horn-type rudder are smaller than those of Spade rudder with same lift force. But it is found that the rudder cavitation occurs on a Horn-type rudder of fast container ship. In this paper the comparison results of Horn-type and Spade rudders are described. HPMM tests are carried out to compare the effects of two rudder types on the maneuverability of a ship. It is shown that the maneuvering performance of a ship equipped with Horn-type rudder is better than that equipped with Spade rudder by comparing the test results and maneuvering coefficients at scantling condition. The reason is that the movable part area of Horn-type rudder is about 14% larger than that of Spade rudder with same total area. And the rudder torque of Spade rudder is greater than that of Horn rudder. At ballast condition, however, the effect of rudder type is negligible.