Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.

Air Leakage Analysis of Research Reactor HANARO Building in Typhoon Condition for the Nuclear Emergency Preparedness

  • Lee, Goanyup;Lee, Haecho;Kim, Bongseok;Kim, Jongsoo;Choi, Pyungkyu
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.354-358
    • /
    • 2016
  • Background: To find out the leak characteristic of research reactor 'HANARO' building in a typhoon condition Materials and Methods: MELCOR code which normally is used to simulate severe accident behavior in a nuclear power plant was used to simulate the leak rate of air and fission products from reactor hall after the shutdown of the ventilation system of HANARO reactor building. For the simulation, HANARO building was designed by MELCOR code and typhoon condition passed through Daejeon in 2012 was applied. Results and Discussion: It was found that the leak rate is $0.1%{\cdot}day^{-1}$ of air, $0.004%{\cdot}day^{-1}$ of noble gas and $3.7{\times}10^{-5}%{\cdot}day^{-1}$ of aerosol during typhoon passing. The air leak rate of $0.1%{\cdot}day^{-1}$ can be converted into $1.36m^3{\cdot}hr^{-1}$, but the design leak rate in HANARO safety analysis report was considered as $600m^3{\cdot}hr^{-1}$ under the condition of $20m{\cdot}sec^{-1}$ wind speed outside of the building by typhoon. Conclusion: Most of fission products during the maximum hypothesis accident at HANARO reactor will be contained in the reactor hall, so the direct radiation by remained fission products in the reactor hall will be the most important factor in designing emergency preparedness for HANARO reactor.

A Study on the Life Cycle Energy and $CO_2$ in the Apartment Housings (공동주택의 라이프사이클 에너지와 이산화탄소 추정에 관한 연구)

  • Lee, Kang-Hee;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.89-96
    • /
    • 2008
  • The environment has played a key role to improve the living condition and develop the industry. In building industries, we should consider the environment and mitigate the environmental affect. For mitigating the its affect, various areas of building technology have been developed and applied into filed work. In addition, the process in applying into field requires to conduct the assessment of the environmental affect and improve its applied technology. A lot of assessment methods are proposed in evaluate the building condition such as post-occupancy evaluation, life cycle management and life cycle assessment. Among these assessment methods, life cycle assessment is effectively utilized the environmental affect in building life cycle. Therefore, this paper aimed at analyzing the energy consumption and $CO_2$ emission in building life cycle, using the life cycle assessment and application of the example in apartment housing. This study shows that the maintenance and the production of building materials stage shares most of the amount of energy consumption and $CO_2$ emission and therefore plays an important role to planning the building in terms of the life cycle. Second, the other stages brings about a very small amount. It is important to decide the building shape and contents to mitigate the environmental affect in terms of material, volume, the pattern of the energy use and others.

Development of the Program(FDS2EXODUS) for Generating Hazard condition file of Building-EXODUS code based on the FDS Fire-simulation Data (화재모사전용 FDS code의 계산값을 이용하여 피난해석 BuildingEXODUS code의 피난의 환경조건 파일을 생성하는 프로그램(FDS2EXODUS) 개발)

  • Kim, H.B.;Jang, Y.J.;Jung, W.S.;Park, W.H.;Lee, D.H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.570-575
    • /
    • 2009
  • In this paper shows the development of the Program(FDS2EXODUS) for Generating Hazard condition file of BuildingEXODUS code based on the FDS Fire-simulation Data. The program were applied with numerical method to translate from FDS to BuildingEXODUS. Using both single or multi block meshes of FDS get to be possible. For application of fire effect, the fire data were loaded directly to BuildingEXODUS in the case of FDS code with using this Program(FDS2EXODUS). It was very convenient to input to BuildingEXODUS and could be reduced the procedure of egress simulation from fire disaster.

  • PDF

The Current Status Analysis and Improvement of Green Building Education through Expert Survey (전문가 인식조사를 통한 녹색건축물 교육 실태분석과 개선방안 연구)

  • Kim, Yong-Gook;Song, Yu-Mi;Cho, Young-Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.49-57
    • /
    • 2018
  • The purpose of this study is to analyze the current condition of green building education, which is a necessary condition to activate green architecture, with the need to reduce greenhouse gas emissions in the building sector. The main results are as follows. First, the level of education and the level of domestic green architecture were generally underestimated. Second, in order to increase the satisfaction of participants in green building education, it is necessary to increase the number of courses and to increase the number of lecturers who have excellent practical skills. Third, there is a need to strengthen green building programs related to BEMS and green remodeling. Fourth, it is necessary to expand the education on green architecture for the people in the architectural planning and design field and the related field officials. Fifth, green building education needs to be implemented in conjunction with curriculum of elementary, middle and high school. Sixth, it is necessary to diversify the PR(public relations) channels of the green building education program and to provide a way to give the employment increase point when the curriculum is completed. Seventh, there is a need to expand administrative and financial incentives for green architecture in order to revitalize green architecture education.

Anomaly Detection and Diagnostics (ADD) Based on Support Vector Data Description (SVDD) for Energy Consumption in Commercial Building (SVDD를 활용한 상업용 건물에너지 소비패턴의 이상현상 감지)

  • Chae, Young-Tae
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.579-590
    • /
    • 2018
  • Anomaly detection on building energy consumption has been regarded as an effective tool to reduce energy saving on building operation and maintenance. However, it requires energy model and FDD expert for quantitative model approach or large amount of training data for qualitative/history data approach. Both method needs additional time and labors. This study propose a machine learning and data science approach to define faulty conditions on hourly building energy consumption with reducing data amount and input requirement. It suggests an application of Support Vector Data Description (SVDD) method on training normal condition of hourly building energy consumption incorporated with hourly outdoor air temperature and time integer in a week, 168 data points and identifying hourly abnormal condition in the next day. The result shows the developed model has a better performance when the ${\nu}$ (probability of error in the training set) is 0.05 and ${\gamma}$ (radius of hyper plane) 0.2. The model accuracy to identify anomaly operation ranges from 70% (10% increase anomaly) to 95% (20% decrease anomaly) for daily total (24 hours) and from 80% (10% decrease anomaly) to 10%(15% increase anomaly) for occupied hours, respectively.

Condition assessment of aged underground water tanks-Case study

  • Zafer Sakka;Ali Saleh;Thamer Al-Yaqoub;Hasan Karam;Shaikha AlSanad;Jamal Al-Qazweeni;Mohammad Mosawi;Husain Al-Baghli
    • Structural Engineering and Mechanics
    • /
    • v.90 no.5
    • /
    • pp.493-504
    • /
    • 2024
  • This paper presents the methodology and results for the investigation of the structural safety of 40 aged underground water tanks to support the weight of photovoltaic (PV) systems that were supposed to be placed on their roof reinforced concrete (RC) slabs. The investigation procedure included (1) review of available documents; (2) visual inspection of the roof RC slabs; (3) carrying out a series of nondestructive (ND) tests; and (4) analysis of results. Out of the 40 tanks, eleven failed the visual inspection phase and were discarded from further investigation. The roof RC slabs of the tanks that passed the visual inspection were subjected to a series of ND tests that included infrared thermography, impact echo, ultrasonic pulse velocity (UPV), Schmidt hammer, concrete core compressive strength, and water-soluble chloride content. The NDT results proved that eight more tanks were not suitable to support the PV systems. Based on the results of the visual inspection and testing, a probabilistic decision-making criterion was established to reach a decision regarding the structural integrity of the roof slabs. The study concluded that the condition of the drainage filter was essential in protecting the tanks and its intact presence can be used as a strong indication of the structural integrity of the roof RC slabs.

The Method on Safety and Maintenance Based Domestic Infrastructure Facilities for Survey of Actual Condition (안전 및 유지관리기반 국내 인프라 실태조사 수행 방안)

  • Lee, Jeong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.230-231
    • /
    • 2015
  • Recently, although researching and developing of safety and maintenance on domestic infrastructure facilities in KOREA are important, there has been very little research regarding on a comprehensive and integrated survey of actual condition. Therefore this study asserts the necessity of the survey process of actual condition by period planning(short-term, middle-term, long-term). The purpose of this study is to investigate current situation and to suggest the whole process method, and to establish survey process of actual condition on domestic infrastructure facilities.

  • PDF

Experimental Examination of Nonslip Technique of Floors (바닥의 미끄럼 방지기술에 관한 실험적 검토)

  • Shin, Yoon-Ho;Baek, Koen-Hyuk;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.235-238
    • /
    • 2009
  • The study of our investigating and analyzing through experiments the performance on nonslip techniques, which has been nationally applied and represented, showed the following results. 1) In wearing shoes condition, regardless the shape of the surface and surface condition of the object, it satisfied the performance standard in cleaned and dried condition and the pulverulent body mixed liquid dispersed moisture condition. However, for the case of the non-slip agent treatment, not likely as the non-slip tape treatment case, the effect was not approved as it shows almost the same CSR as none treatment. 2) In bare foot condition, it satisfied the performance standard in most of the objects except for the Ceramic tile (A), Ceramic tile (B), pure and soapy water dispersed condition.

  • PDF

Analysis of Earth Design Parameter and Geothermal Heat Exchanger Length in Geothermal System (지열시스템의 지중 설계요소와 지중열교환기 길이 분석)

  • Park, Jong-II;Park, Kyung Soon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2015
  • In this study, we analyzed t he design condition for appropriate design factor at geothermal system design documents. It is intended to provide the proper information of geothermal system design condition when construct new building, designer can use design conditions more efficiently. Therefore, it is possible to plan for domestic geothermal system, through utilization at design element, to provide as a good information that can predict the approximate underground condition. Thus, provided the basic design conditions that can predict the capacity of the geothermal system. It will be the first step to solve the problem.