• Title/Summary/Keyword: Building Condition

Search Result 1,918, Processing Time 0.036 seconds

A Study on the Improvement of Member Evaluation Method in the Condition Evaluation of Reinforced Concrete Buildings (철근콘크리트 건축물의 상태평가 중 부재평가방법 개선에 관한 연구)

  • Woo, Hye-Sung;Yi, Waon-Ho;Hwang, Kyung-Ran;Lee, Kwan-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.85-91
    • /
    • 2021
  • Type 1 and type 2 buildings must regularly conduct precise safety inspections and precise safety diagnosis for the safety and maintenance of facilities, and the safety grade of the building is determined according to the results of the implementation. In addition, the cycle of inspection and diagnosis is determined according to the safety grade of the building. In order to determine the safety grade of the building, a precise safety inspection conducts condition evaluation, and a precise safety diagnosis conducts condition evaluation and safety evaluation. Therefore, since the inspection and diagnosis cycle is determined according to the safety grade of the building, the condition evaluation and safety evaluation must be precise. However, in the case of member unit evaluation, which is the first step in evaluating the current condition, the evaluation grade is determined by using the representative value of the measurement result, and this may result in an error in the evaluation grade. To solve this problem, this study analyzed evaluation criteria for each evaluation item and presented evaluation criteria using inequalities to respond to measurement results and evaluation scores. In addition, we present a functional formula that can reflect performance scores for each evaluation item.

A Study on the Development of Type & Planning Criteria for the Senior citizen who lives alone in Home for the Elderly - A study on the model of co-housing for senior citizen who lives alone in the rural and fishing village (VI) - (독거노인용 경로홈의 유형개발과 계획기준의 연구 - 농어촌 독거노인을 위한 친환경 공동주거의 모형개발 연구(6) -)

  • Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.4
    • /
    • pp.27-35
    • /
    • 2012
  • The purpose of this study was to establish planning criteria and development of type for the senior citizen who lives alone in home for the elderly at rural and fishing villages. In order to take most suitable co-housing, this analysis is progressed various building types based on aging in place and aging in health; self care, nono care, service care and community care. This paper is to suggest collective housing with 10 types in large scale and extracted 19 types in detail scale. The basis of classification are location condition; aging in place, building condition, health care condition; aging in health and possession & operation condition. In viewpoint of dwelling welfare 'Home for the Elderly' is to concerned with systematic methodology and architectural typology for senior citizen who lives alone in the rural and fishing village.

A Study on the Safety Diagnosis for Power Systems Using a UV Camera (자외선 검출 카메라를 이용한 전력시스템의 안전진단에 관한 연구)

  • Yu, Byeong-Yeol;Kim, Chan-O
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.7-13
    • /
    • 2012
  • This paper describes the diagnosis techniques using UV images taken in the field under energized condition of power equipments in order to figure out and analyze the abnormal states on the terminals of power equipments. To classify the features of the terminals, the counted No. of the corona generated at the terminals is defined. According to the result detected, the No. of corona detected on the power equipments installed inside a building is less than that installed outside a building, and it strongly depends on the environment and installed condition. Thus, the environmental condition needs enhanced, and stable operation by the periodic inspection under energized condition of the power equipments is required. Especially, the event counting technique using UV camera is useful for the power equipments apart more than 20 m to apply, and there can be an error due to the features of the sensing techniques when the distance between the user and the objects is close less than 15 m. Therefore, the experimental result shows that event counting technique is employed in the case of the distance more than 15 m. The electrical safety can be ensured by using the UV detection technique and the criteria.

Survey evaluation of thermal boundary condition in the inside and outside of double skin facade

  • Shin, Hyun-Cheol;Jang, Gun-Eik
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.29-35
    • /
    • 2015
  • Purpose: Double skin facade is a representative advantageous passive technology of building skin in the aspect of energy saving and environment improvement, reduces heat loss with buffer space in winter season and enhances indoor air and comfort of residents by activating natural ventilation in mid-season. However, in summer season, temperature increase in the intermediate space due to solar energy from exterior transparent skin could be a potential problem; also, relatively weak buoyancy of air caused by low density difference between double-skin facade could increase cooling load as air of intermediate space in high temperature hangs. However, proof data is insufficient to objectify such phenomenon. Method: In this study, researchers surveyed air temperature of intermediate space and airflow and diagnosed its cause targeting on applied multistory facade in the building which gives thermal uncomfort to residents. Also, the researchers produced Solar-air heat transfer coefficient meter, measured thermal boundary condition of double-skin facade, and presented the result of measurement as an objectified verification material regarding overheating phenomenon in the intermediate space of double-skin facade in summer season. Result: Inefficient condition was verified that total heat increases and overheating due to insufficient natural ventilation in multistory facade. In addition, logic behind preceding research was objectified and verified regarding high temperature phenomenon in the intermediate space which could increase cooling load in summer season.

A Study on the Conservation and Reuse of Historical Heritage - Case Study of Naju′s Old Railway Station Building - (역사적 유산의 보존과 활용에 관한 연구 - 구 나주역사를 중심으로 -)

  • Kim Hongii
    • Journal of the Korean housing association
    • /
    • v.15 no.4
    • /
    • pp.25-34
    • /
    • 2004
  • The purpose of this study was to analyzes the transition process and architectural characteristics of Naju's old railway station building from 1913 to 2002. It considers measures for the conservation and reuse. It analyzes investigation record of the condition of Naju's station from 1948 to 1993 and standard building design at Japanese colonial period. It analyzes as well, transition of building through the comparison of the results of an investigation in 1993 and those of the present conditions. In addition, it analyzes interviews with the city officials and residents in city.

The Operating Characteristics of 3kW BIPV System (3kW BIPV시스템의 운전특성)

  • Kim J.H.;Park J.M.;Choi Y.O.;Choi S.J.;Cho G.B.;Baek H.R.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.552-554
    • /
    • 2006
  • BIPV(Building Integrated PV) system can expect dual effects that reduce expenses for establishment of PV system by adding new function as outer covering material of building expect producing the electricity. But, there are many generation differences according to the exterior environmental facts(solar cell array, design and installation condition of interactive inverter system) Therefore, it is difficult to optimum design. Consequently in advance design system, we experiment 3kW BIPV(Building Integrated PV) generation. We concrete PV system efficient application of variable. BIPV system that is proposed in this paper, was established in Solar Energy research center of Chosun University, composed with system. This research is a basic study for application of building integrated photovoltaic system for building

  • PDF

A Fundamental Study on the Daylighting Characters of Atrium Building (Atrium Builing의 자연채광특성에 관한 기초적 연구)

  • Kim, Hwy-Sub;Choi, In-Chang;Seo, Juong-Ho
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.21-27
    • /
    • 1992
  • This study is presents model testing to evalute daylighting performance in Atrium Building. There are several methods fof the prediction of Daylighting level in a Atrium Building, But they are not sufficient to estimate intreior daylight level of each different hights onleaner Atrium Building. In this study provide with making the model to estimate the environmental effect for the daylight on leaner Atrium, measuring the model in 80 variable sky condition, building direction, interior length-width ratio through the variation of floor-hight and space ratio.

  • PDF

Performance Monitoring Study of Building Integrated Geothermal System in Winter (건물일체형 지열시스템의 동계 성능 모니터링 연구)

  • Yu, Hyung-Kyu;Bae, Sang-Hwan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • The objective of this study is to develope ground heat exchanger using PHC pile used to building foundation, and it's element technology. So we made PHC piles into ground heat exchanger and evaluate it's performance. First, we studied PHC pile type, heat exchanger pipe, grouting materials, and present apartment house's foundation condition for PHC ground heat exchanger. As a result we designed BIGS(Building Integrated Geothermal System) prototype. Second, we applied BIGS to apartment houses' utility building in Osan built by Daelim. Third, we monitored heating performance of winter season. 1be result of heating performance was so good to apply to heat & cooling system in building.

A Study of Optimum Control in Building HVAC System using Reinforce Signal (강화신호를 이용한 건물공조시스템의 최적제어에 관한 연구)

  • Cho Sung-Hwan;Yang Sung-Hee;Yang Hooncheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1068-1076
    • /
    • 2004
  • Technology on the proportional integral (PI) control have grown rapidly owing to the needs for the robust capacity of the controllers from industrial building sectors. However, PI controller requires tuning of gains for optimal control when the outside weather condition changes. The present study presents the possibility of reinforcement learning (RL) control algorithm with PI controller adapted in the HVAC system. The optimal design criteria of RL controller was proposed in the Environment Chamber experiment and a theoretical analysis was also conducted using TRNSYS program.