• 제목/요약/키워드: Building Component

검색결과 640건 처리시간 0.03초

A Component Model for Managing Covid-19 Crisis

  • Taweel, Faris M.
    • International Journal of Computer Science & Network Security
    • /
    • 제21권7호
    • /
    • pp.365-373
    • /
    • 2021
  • Covid-19 posed a serious threat to public health worldwide, especially in the absence of vaccines or medicines. The only viable strategies to combat a virus with a high infection rate were to apply lock-down strategies, transport ban, social and physical distancing. In this work, we provide a domain-specific component model for crisis management. The model allows for building a plan for managing Covid-19 crisis and use the plan as a template to generate a system specific for managing that crisis. The crisis component model is derived from X-MAN II, a generic component model that we have developed for the aircraft industry

혼화재 혼입 시멘트 페이스트의 수화생성물 정량 분석 (Quantitative Analysis of Hydrate products of the Cement Paste Mixed with Admixtures)

  • 박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.176-177
    • /
    • 2021
  • In order to compensate for the defects of concrete made using only Portland cement, three-component powder mixed with blast slag and fly ash, and four-component powder concrete mixed with silica fume are being produced. When each of the admixtures is used alone, the above-described excellent performance is expressed and up to 70% of the powder is used. These technologies are also contributing to the reduction of greenhouse gases under Act on Low Carbon. Green Growth. However, calcium hydroxide is consumed as a stimulator or reaction in the case of silica fume, which causes latent hydroponicity of slag, pozzolane reaction, and silica mixtures represented by fly ash. It is known that the consumption of calcium hydroxide affects the alkalinity of concrete. As a result, the carbonation resistance is significantly lower among the durability of concrete. Research on quantification of such effects is insufficient. In this study, an experiment was conducted to quantify calcium hydroxide of the three-component and four-component powder paste using thermal analysis equipment (DTG), and the effect of the mixing amount was discussed.

  • PDF

Evaluation of seismic performance of mid-rise reinforced concrete frames subjected to far-field and near-field ground motions

  • Ansari, Mokhtar;Ansari, Masoud;Safiey, Amir
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.453-462
    • /
    • 2018
  • Damages to buildings affected by a near-fault strong ground motion are largely attributed to the vertical component of the earthquake resulting in column failures, which could lead to disproportionate building catastrophic collapse in a progressive fashion. Recently, considerable interests are awakening to study effects of earthquake vertical components on structural responses. In this study, detailed modeling and time-history analyses of a 12-story code-conforming reinforced concrete moment frame building carrying the gravity loads, and exposed to once only the horizontal component of, and second time simultaneously the horizontal and vertical components of an ensemble of far-field and near-field earthquakes are conducted. Structural responses inclusive of tension, compression and its fluctuations in columns, the ratio of shear demand to capacity in columns and peak mid-span moment demand in beams are compared with and without the presence of the vertical component of earthquake records. The influences of the existence of earthquake vertical component in both exterior and interior spans are separately studied. Thereafter, the correlation between the increase of demands induced by the vertical component of the earthquake and the ratio of a set of earthquake record characteristic parameters is investigated. It is shown that uplift initiation and the magnitude of tensile forces developed in corner columns are relatively more critical. Presence of vertical component of earthquake leads to a drop in minimum compressive force and initiation of tension in columns. The magnitude of this reduction in the most critical case is recorded on average 84% under near-fault ground motions. Besides, the presence of earthquake vertical components increases the shear capacity required in columns, which is at most 31%. In the best case, a direct correlation of 95% between the increase of the maximum compressive force and the ratio of vertical to horizontal 'effective peak acceleration (EPA)' is observed.

GREEN CONSTRUCTION: U.S. CONSTRUCTION RELATED COMPANIES' STATUS AND PERCPETION

  • Yong Han Ahn;Annie R. Pearce;Kihong Ku
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.263-271
    • /
    • 2009
  • This study reveals the status, perceptions, and future directions associated with green building within construction-related companies. A survey research method was used to capture current experience levels and capabilities of companies with regard to green construction. Expectations and perceptions about the future of the construction industry with regard to green building were obtained from construction-related companies recruiting from the Myers-Lawson School of Construction at Virginia Tech from 2006 and 2008. The findings of this study support the growing importance of green building as a component of the whole construction market and provide a benchmark against which to measure future changes in the industry over time.

  • PDF

부산시 500m 메시 레벨에서의 건물용도 구성에 따른 유형화 분석 (An Analysis on the 500m - Mesh Classification based on the Combinations of Building Needs in Busan)

  • 황광일;최덕인;김다혜;양잉찬;윤소라
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2010년도 춘계학술대회
    • /
    • pp.191-192
    • /
    • 2010
  • 본 연구는 부산광역시를 대상으로 작성한 500m메시 별 건물용도별 면적 구성에 근거한 유형화에 대한 연구이다. 본 연구에서는 3289개의 유효한 메시를 대상으로 7개 용도군에 대한 데이터 베이스를 구축하였고, 그중 주거용, 상업용, 교육용 공간이 전체 공간의 92.4%를 차지하고 있으며, 용적율 50% 이상인 메시는 325개로 전체의 약 10% 수준이었다. 다양한 변수를 단순화하기 위해 주성분분석을 수행하였고 그 결과를 이용하여 클러스터분석을 수행하여 모든 메시를 5개 유형으로 분류하였다.

  • PDF

Peak pressures on low rise buildings: CFD with LES versus full scale and wind tunnel measurements

  • Aly, Aly Mousaad;Gol-Zaroudi, Hamzeh
    • Wind and Structures
    • /
    • 제30권1호
    • /
    • pp.99-117
    • /
    • 2020
  • This paper focuses on the processes of wind flow in atmospheric boundary layer, to produce realistic full scale pressures for design of low-rise buildings. CFD with LES turbulence closure is implemented on a scale 1:1 prototype building. A proximity study was executed computationally in CFD with LES that suggests new recommendations on the computational domain size, in front of a building model, apart from common RANS-based guidelines (e.g., COST and AIJ). Our findings suggest a location of the test building, different from existing guidelines, and the inflow boundary proximity influences pressure correlation and reproduction of peak loads. The CFD LES results are compared to corresponding pressures from open jet, full scale, wind tunnel, and the ASCE 7-10 standard for roof Component & Cladding design. The CFD LES shows its adequacy to produce peak pressures/loads on buildings, in agreement with field pressures, due to its capabilities of reproducing the spectral contents of the inflow at 1:1 scale.

창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석 (Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung)

  • 김민휘;김진효;권오현;한욱;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF

공동주택 구성재의 경제적 수선형태 설정 연구 (A Study on the Economic Repair Pattern of the Building Components in the Apartment Housing)

  • 이강희;채창우
    • 한국주거학회논문집
    • /
    • 제17권5호
    • /
    • pp.87-95
    • /
    • 2006
  • Building components have been deteriorated by various factors such as location, a building type, a surrounding environment and so on. In addition, each component has a peculiar characteristics, compared with other components in properties of matter an used part. Building components would be required to maintain its function and performance to provide the resident with a decent living condition. It is important to decide the repair time, scope and a required cost in repair plan, considering the each component's characteristics. In this parer, it aimed at providing the economic repair pattern to analyze the relation of the time-elapse and the cumulative repair cost in the apartment housing using 3rd quadratic function. Results of the study are as follows: First, the shape of the function for the economic repair is classified into two type. One is the continuous increase type of the cumulative cost which properly means the iterative repair type after built. The other is that the function has the maximum state at a point which means one-repair after its repair would be delayed to a scheduled time. Second, the iterative repair pattern would include window, roof proof, lighting and water supply pipe. The other repair pattern would include the paintings, heating pipe and sign board.

부분모드 방법을 이용한 점탄성 감쇠기가 설치된 건물의 고유치 해석 (Eigenvalue Analysis of the Building with Viscoelastic Dampers Using Component Mode Method)

  • 민경원;김진구;조한욱;이성경
    • 한국지진공학회논문집
    • /
    • 제2권1호
    • /
    • pp.71-78
    • /
    • 1998
  • 본 연구는 점탄성 감소기가 설치된 건물의 고유치 해석을 위하여 라그라란지 승수 방법(Lagrage multiplier formulating)을 이용하였다. 특성방정식은 건물의 고유진동수, 감소기가 설치된 층의 모드 성분, 감쇠기의 점성 및 강성에 관계된 식으로 나타났으며, 감쇠기의 점성으로 인하여 복소수의 형태로 표현이 되었다. 유도된 특성방정식은 고유치 해석을 위한 일반적인 형태의 식이 아니므로 본 연구에서는 그림 해석을 통하여 감쇠기의 설치로 인한 점성과 증가로 건물의 복소 고유진동수의 변화를 분석하는 방법을 제시하였다. 그림 해석으 결과에 따르면 감쇠기의 점성과 강성으로 인한 복소 고유진동수의 물리적인 의미를 확인할 수 있으며, 최소 및 최대값을 예측할 수 있다. 또한, 복소 고유진동수를 실수의 고유진동수와 모드 감쇠비로 변환하여 상태방정식에 의한 방법의 결과와 비교하여 정확성을 검증하였다.

  • PDF

Numerical study on the effects of seismic torsional component on multistory buildings

  • Ouazir, Abderrahmane;Hadjadj, Asma;Benanane, Abdelkader
    • Earthquakes and Structures
    • /
    • 제13권1호
    • /
    • pp.9-15
    • /
    • 2017
  • In this paper, the influence of the rotational component, about a vertical axis, of earthquake ground motion on the response of building structures subjected to seismic action is considered. The torsional component of ground motion is generated from the records of translational components. Torsional component of ground motion is then, together with translational components, applied in numerical linear dynamic analysis of different reinforced concrete framed structure of three stories buildings. In total, more than 40 numerical models were created and analyzed. The obtained results show clearly the dependence of the effects of the torsional seismic component on structural system and soil properties. Thus, the current approach in seismic codes of accounting for the effects of accidental torsion due to the torsional ground motion, by shifting the center of mass, should be reevaluated.