• Title/Summary/Keyword: Building Code and Regulations

Search Result 43, Processing Time 0.024 seconds

Earthquake performance of FRP retrofitting of short columns around band-type windows

  • Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • v.53 no.1
    • /
    • pp.1-16
    • /
    • 2015
  • Due to design codes and regulations and the variety of building plans in Turkey, it is very often seen that band-type windows are left for ventilation and lightening of the basements of buildings which are used for various purposes such as workplaces and storage. Therefore when the necessary support measures cannot be given, short columns are subjected to very high shear forces and so damage occurs. One of the precautions to avoid the damage of short column mechanisms in buildings where band-type windows are in the basement is to strengthen the short columns with fiber reinforced polymer (FRP). In this study, the effect of the FRP retrofitting process of the short columns around band-windowed structures, which are found especially in basement areas, is analyzed in accordance with Turkish Seismic Code 2007 (TSC 2007). Three different models which are bare frame, frame with short columns and retrofitted short columns with FRP, are created and analyzed according to TSC 2007 performance analysis methods to understand the effects of band windows in basements and the effect of FRP retrofitting.

An Experimental Study for Vertical Flame Spread Analysis of Aluminum Composite Panel (알루미늄 복합 패널의 수직 화염전파속도 분석을 위한 실험적 연구)

  • Kim, Il-Kwon;Kim, Bong-Chan;Ku, In-hyuck;Seo, Dong-Gu;Lim, Nam Gi;Kwun, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.315-317
    • /
    • 2013
  • To analyze vertical fire spreadability of aluminum composite panel, real scale test of aluminum composite panel and fire retardant aluminum composite panel was conducted as well as analysis of domestic code, test and domestic reaserch resulted in following conclusion. Fire spread risk assessment of aluminum Composite Panel is impossible with the current regulations (Cone Calorimeter Test). It need to changes of regulatory and combustion expanded risk assessment and regulatory changes in the test methods need to be judged. Also, there is quite a big different between the general aluminum Composite Panel and semi-non combustible of aluminum Composite Panel. However it is also deemed to be danger when present in the sidewall to the top consisting of fire spread. From now on, it is needed the study about interpretation of fire spread and sidewall of vertical fire spread analysis not only experiments for aluminum Composite Panel.

  • PDF

Investigating Structural Stability and Constructability of Buildings Relative to the Lap Splice Position of Reinforcing Bars

  • Widjaja, Daniel Darma;Rachmawati, Titi Sari Nurul;Kwon, Keehoon;Kim, Sunkuk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.315-326
    • /
    • 2023
  • The design principles and implementation of rebar lap splice in architectural structures are governed by building regulations. Nevertheless, the minimization of rebar-cutting waste (RCW) is often impeded by the mandatory requirements pertaining to the rebar lapping zone as prescribed in design codes. In real-world construction scenarios, compliance with these rules often falls short due to hurdles concerning productivity, quality, safety, time, and cost. This discrepancy between code stipulations and on-the-ground construction practices necessitates an academic exploration. The goal of this research was to delve into the effect of rebar lap splice placement on the robustness and constructability of building edifices. The study initially took on a review of the computation of rebar lapping length and the rules revolving around the lapping zone. Following this, a structural robustness and constructability examination was undertaken, focusing on adherence to the lap splice zone. The interpretations and deductions of the research led to the following insights: (1) the efficacy of rebar lap splice is not solely contingent on the moment, and (2) the implementation of rebar lap splice beyond the specified zone can match the structural integrity and robustness of those confined within the designated area. As a result, the constraints on the rebar lapping zone ought to be revisited and possibly relaxed. The conclusions drawn from this research are anticipated to reconcile the disconnect between building codes and practical construction conditions, furnishing invaluable academic substantiation to further the endeavor of achieving near-zero RCW.

A Methodology for Using ChatGPT to Improve BIM-based Design Data Evaluation System (BIM기반 설계데이터 평가 시스템 개선을 위한 ChatGPT활용 방법론)

  • Yu, Eun-Sang;Kim, Gu-Taek;Ahn, Yong-Han;Choi, Jung-Sik
    • Journal of KIBIM
    • /
    • v.14 no.2
    • /
    • pp.25-34
    • /
    • 2024
  • This study proposes a new methodology to increase the flexibility and efficiency of the design data evaluation system by combining Building Information Modeling (BIM) technology in the architectural industry, OpenAI's interactive artificial intelligence, and ChatGPT. BIM technology plays an important role in digitally modeling and managing architectural information. Since architectural information is included, research and development are underway to review and evaluate BIM data according to conditions through program development. However, in the process of reviewing BIM design data, if the review criteria or evaluation criteria according to design change occur frequently, it is necessary to update the program anew. In order for designers or reviewers to apply the changed criteria, requesting a program developer will delay time. This problem was studied by using ChatGPT to modify and update the design data evaluation program code in real time. In this study, it is aimed to improve the changing standards and accuracy by enabling programming non-professionals to change the design regulations and calculation standards of the BIM evaluation program system using ChatGPT. In this study, in the BIM-based design certification automation evaluation program, a program in which the automation evaluation method is being studied based on the design certification evaluation manual was first used. In the design certification automation evaluation program, the programming non-majors checked the automation evaluation code by linking ChatGPT, and the changed calculation criteria were created and modified interactively. As a result of the evaluation, the change in the calculation standard was explained to ChatGPT and the applied result was confirmed.

A Study on the Improvement of Legal Policies for Activating Public Open Space in Urban Environment Improving Project of Seoul City (서울시 도시환경정비사업 내 공개공지 활성화를 위한 제도개선에 관한 연구)

  • Kim, Do-Kyong;Kim, Kun-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.5
    • /
    • pp.21-32
    • /
    • 2011
  • The district units planning suggests not only detailed standards of building as parts of the whole plan in the district but also a guideline of the arrangement, shape and pavement of the public open space, in order to move away from the rigid image of an institution which causes the formal creation of it. This triggered various problems. While the basic plan for adjustment of urban environments(established in 2005) was being reorganized in order to reflect changed conditions of the city center, the sector of public open space was subdivided according to the guidelines of development by district. We conducted a comparative analysis of conditions before and after the adjustment, so as to examine whether or not the reorganized institution is effective for the plan of public open spaces. The analysis showed that there was no remarkable change between the basic plan and the reorganized institution in that items which were not any different from the existing building codes were established due to lack of guidelines related to public open space under the law of urban and residential environmental improvement. Low regulations should set up criteria for establishment from a concrete, effective microscopic aspect appropriate to the significance of public open space by the linking of public open space and the surrounding environment, whereas high regulations such as building codes should specify essential components.

Differences on specified and actual concrete strength for buildings on seismic zones

  • De-Leon-Escobedo, David;Delgado-Hernandez, David Joaquin;Arteaga-Arcos, Juan Carlos;Flores-Gomora, Jhonnatan
    • Earthquakes and Structures
    • /
    • v.12 no.3
    • /
    • pp.349-357
    • /
    • 2017
  • The design of reinforced concrete structures strongly depends on the value of the compression concrete strength used for the structural components. Given the uncertainties involved on the materials quality provided by concrete manufacturers, in the construction stage, these components may be either over or under-reinforced respect to the nominal condition. If the structure is under reinforced, and the deficit on safety level is not as large to require the structure demolition, someone should assume the consequences, and pay for the under standard condition by means of a penalty. If the structure is over reinforced, and other failure modes are not induced, the builder may receive a bonus, as a consequence of the higher, although unrequested, building resistance. The change on the building safety level is even more critical when the structure is under a seismic environment. In this research, a reliability-based criteria, including the consideration of expected losses, is proposed for bonification/penalization, when there are moderated differences between the supplied and specified reinforced concrete strength for the buildings. The formulation is applied to two hypothetical, with regular structural type, 3 and 10 levels reinforced concrete buildings, located on the soft soil zone of Mexico City. They were designed under the current Mexican code regulations, and their responses for typical spectral pseudoaccelerations, combined with their respective occurrence probabilities, are used to calculate the building failure probability. The results are aimed at providing objective basis to start a negotiation towards a satisfactory agreement between the involved parts. The main contribution resides on the explicit consideration of potential losses, including the building and contents losses and the business interruption due to the reconstruction period.

A Study on Requirements for Facilities' Changes with the changes in Legislations and Education Curriculum of Infants (영유아 관련 법령 및 교육과정 변천 비교에 따른 시설 변화 요구사항 연구)

  • Jung, Eu-Gene;Oh, Byeong-Uk;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.1
    • /
    • pp.3-11
    • /
    • 2014
  • The policies is always changes according to the changing times, and changes take place in educational facilities welfare policy. Early childhood facilities, is no exception. Recent, increase in the number of kindergarten and kindergarten children according to policy changes of government's active welfare. This change in pattern, policy changes and increased support to know the impact on the community, and this is not just a simply agenda that they need to be recognized social change. In addition, it can be seen changes in relevant laws and educational process according to childhood policy change flow and depending on social change. In this study, comparative study infants and installation of the facility based on criteria, ensuring standards of early childhood facility site, facilities of evolution of infants care act, act infants, infants of activities safety management. And Standards and facilities that are required to change the direction of the revision is for the purpose of research through changes in kindergarten curriculum to respond the policies flow. Research methods are literature on the various laws and research analysts, leading comparison of different child care and child care policy changes in laws and regulations to review materials are analyzed.

Behavior factor of vertically irregular RCMRFs based on incremental dynamic analysis

  • Habibi, Alireza;Gholami, Reza;Izadpanah, Mehdi
    • Earthquakes and Structures
    • /
    • v.16 no.6
    • /
    • pp.655-664
    • /
    • 2019
  • Behavior factor of a structure plays a crucial role in designing and predicting the inelastic responses of it. Recently, irregular buildings have been interested in many designers. To design irregular structures, recognizing the inelastic behavior of them is necessary. The main objective of this study is to determine the behavior factor of irregular Reinforced Concrete Moment Resisting Frames (RCMRFs) via nonlinear Incremental Dynamic Analysis (IDA). To do so, first, several frames are designed according to the regulations of the Iranian national building code. Then the nonlinear incremental dynamic analysis is performed on these structures and the behavior factors are achieved. The acquired results are compared with those obtained using pushover analysis and it is shown that the behavior factors acquired from the nonlinear incremental dynamic analysis are somewhat larger than those obtained from pushover analysis. Eventually, two practical relations are proposed to predict the behavior factor of irregular RCMRFs. Since these relations are based on the simple characteristics of frames such as: irregularity indices, the height and fundamental period, the behavior factor of irregular RCMRFs can be achieved efficiently using these relations. The proposed relations are applied to design of four new irregular RCMRFs and the outcomes confirm the accuracy of the aforementioned relations.

Comparison of displacement capacity of reinforced concrete columns with seismic codes

  • Cansiz, Sinan;Aydemir, Cem;Arslan, Guray
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.295-304
    • /
    • 2019
  • The lateral displacement or drift may be the cause of the damage in the reinforced concrete (RC) columns under the seismic load. In many regulations, lateral displacement was limited according to the properties of columns. The design displacement limits may be represented indirectly through the material strain limits and the mechanical properties of columns. EUROCODE-8 and FEMA356 calculate displacement limits by taking into account the mechanical properties of columns. However, Turkey Building Earthquake Code (TBEC) determine displacement limits by taking into account the material strain limits. The aim of this study is to assess the seismic design codes for RC columns through an experimental study. The estimates of seismic design codes have been compared with the experimental results. It is observed that the lateral displacement capacities of columns estimated according to some seismic codes are not in agreement with the experimental results. Also, it is observed that TBEC is conservative in the context of the performance indicator of RC columns, compared to EUROCODE-8 and FEMA356. Moreover, in this study, plastic hinge length and effective stiffness of test elements were investigated.

Method of Determination of Seismic Design Parameters for the Next Generation of Design Provisions (차세대 내진 설계 규준을 위한 계수 결정 방법)

  • 한상환;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.88-96
    • /
    • 1995
  • Seismic design provisions in Korea has developed based on seismic provisions in United States (e.g., ATC 3-06). Current seismic design provisions in U .S. is moving toward adopting enhanced concept for design. Federal Emergence Management Agency (FEMA) Provides the NEHRP recommended Provisions for the Development of Seismic Regulations for New Buildings which can be used as a source document for use by any interested members of the building community. Current seismic design provisions in U .S. generally use a uni-level force. These provisions can not be satisfied if the limit state design is concerned. Limit state can be defined as a state causing undesirable performance o( a structure (e .g., serviceability, ultimate, buckling, etc.). Even if there are provision for controlling drift by two levels, it is still difficult to satisfy limit states using uni-level force. Architectural Institute of Japan (AIJ) uses a hi-level forces Int seismic loadings which can satisfy serviceability and ultimate limit state. However, the seismic parameters used in AIJ guideline are basically determined by subjective manner of code committee member and professions. These parameters need to be determined based on target quantities (target reliability, target energy dissipation, target displacement, target stress level, etc.). This study develops the method to determine the sesmic design parameters based on a certain taget level. Reliability is used as a target level and load factors in ANSI/ASCE 7-88 are selected as design parameters to be determined.

  • PDF