• Title/Summary/Keyword: Building Arrangement

Search Result 389, Processing Time 0.027 seconds

Ergonomics Job Hazard Evaluation of Building Cleaners

  • Lee, Kyung-Sun;Lee, In-Seok;Kim, Hyun-Joo;Jung-Choi, KyungHee;Bahk, Jin-Wook;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.427-435
    • /
    • 2011
  • Objective: The objective of this study was to evaluate a work of building cleaners using the ergonomic methods. Background: Previous studies about cleaning worker describe typical physical demands of this work. They found that the most significant risk factors associated with the physical work of cleaners are static loads and repetitive movements and high output of force. Method: A head of ergonomics estimation was work analysis(define of combined task, work tool, work time and frequency of combined task) and posture analysis of worker. Results: The results showed that combined task of building cleaners was classification sweeping, mopping(wet), mopping(oil), moving barrels/carts, dumping trash bags, scrubbing, arrangement of cleaning tool, arrangement of circumferential, moving of cleaning tool, and waiting. The work time of combined task such as mopping(wet) and scrubbing indicated high ratio. The posture analysis of building cleaners indicated high value in bending of the head, lower arm, and hands. Conclusion: The findings appear to indicate that building cleaner were related to high risk of work-related musculoskeletal disorders. So, building cleaner would be required an interventional strategy, improvement of cleaning tools and working environment. Application: If ergonomics rule can be integrated into existing cleaning tools and work environments, the risk of occupational injuries will be reduced.

Aerodynamic Characteristics of Neighboring Building Exposed to Twisted Wind

  • Lei Zhou;KamTim Tse;Gang Hu
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.241-263
    • /
    • 2022
  • The conventional wind and twisted-wind effect on aerodynamic properties of neighboring buildings arranged in side-by-side and tandem systems at 2B and 5B spacings are systematically investigated by large eddy simulation. Different physical interactions between different wind profiles and neighboring buildings will be deeply understood. The neighboring-building system under two different types of wind profiles, i.e., conventional wind profile (CWP), twisted wind profiles (TWP) with the maximum twisted angle of 30°, is used to evaluate the variation of physical mechanism between wind and buildings. Aerodynamic characteristics including mean and RMS pressure coefficient, and velocity field were systematically analyzed and compared between different scenario. It was found that the distribution of mean pressure, root-mean-square x velocity and the streamline of wind flow for TWP greatly deviated from CWP, and the effect of TWP on the downstream building, was drastically different from that of CWP, such as the size of vortexes after the lower stream building being bigger when exposed to TWP, and the mean pressure distribution on the building surfaces are also different. Moreover, evidence of buildings arranged in side-by-side and tandem configurations having interchangeable properties under TWP was also discovered, that two buildings being arranged side-by-side exposed to TWP could be identified as being arranged in tandem with a different wind twist angle, or vice versa.

A Study on the Critical Elements in the Commentaries on Competition of the Hospital Architecture in Germany (독일 병원건축 설계경기의 심사평에 나타난 평가항목에 관한 연구)

  • Cho, Ja Yeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.9 no.1
    • /
    • pp.53-60
    • /
    • 2003
  • In this study, I investigate the critical evaluation elements at the architectural competition held nationwide in Germany. These evaluation elements, which can be regarded as the important design evaluation criteria, are selected by the design competition committee. Generally, in Germany the design competition committee consist of professors and famous architects who have theoretical and practical abilities with their own office. I classify and analyze the critical evaluation elements of seventy committee members, working on the selected nine prize-winners in Germany from 1997 to 2001. I conclude that the critical evaluation elements, ordered by frequency are : (1)circulation, (2)context, (3)function, (4)landscape & outside space, (5)organization of space, (6)arrangement of building, (7)form, arrangement of building, (7)form, (7)growth & change, (9)elevation design, (10)utilization of natural light. These design evaluation growth & change, (9)elevation design, (10)utilization of natural light. These design evaluation criteria for Hospital Architecture in Germany also can be applied to the evaluation methods of the korean Healthcare facility design.

  • PDF

A Study on Safety Consciousness for Preventing Accident of The Shipbuilding Industry (조선업 산업재해예방을 위한 안전의식 실태조사)

  • 이윤혁;이상도
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.119-130
    • /
    • 1998
  • The purpose of this study is to investigate the safety consciousness of the lobours working at the ship building or repairing yard at which the industrial accidents frequently happen, and to provide the basic data required for the prevention of those accidents. This study is made by analyzing the questionnaires of 208 labours working at various ship building or repairing industries at random. This questionnaire is focused on finding the basic data for prevention of industrial accidents and getting the public opinions and proposals of labours. The results obtained by this study are as follows ; The negative estimations of the labours to the safety are cultivation of safety consciousness, the safety behavior in company, the molters of arrangement and the estimation of industrial or post arrangement. The positive ones are the arrangements of the protective tools and equipments for safety, the rule of safety regulation and the order of works, and the status of health education within company.

  • PDF

Determination of closet position by room style based on movable furniture layout preference of residents (거주자 가구배치 선호경향을 고려한 실 유형별 붙박이장 위치선정)

  • 진경일
    • Korean Institute of Interior Design Journal
    • /
    • no.40
    • /
    • pp.86-93
    • /
    • 2003
  • Korean traditionally prefer a house with a southern exposure to other styles. Moreover, pretty part of dwelling style in Korea is apartment building. But generally, there are much more north oriented rooms than opposite one in apartment. Generally, most Korean tends to consider the direction of the room as an important factor to decide the arrangement of their furniture. Also, the location of window, door, bed, and closet can affect on the decision-making process of furniture layout. So, the closet position should be determined by not only window direction and door position, but also the furniture arrangement preference of residents. After considering the window and door position, there are 16 alternatives in a room. (Multiplied 4 window directions by 4 door positions under the assumption that the window and the door cannot be on the same side of the wall.) Also, this study analyzed each room style ratio considering the symmetry of each plan by comparing the apartment building plan. This paper studied the bedroom style by analyzing the 180 apartment building plans and survey of furniture layout; the furniture in this study represents bed and desk those are mainly laid in Korean bedroom. Finally, this paper suggested the methodology to find optimal alternatives of furniture and closet layout for high-rise apartment residents, based on the door and window position, and the furniture layout preference of residents.

Application of FE approach to deformation analysis of RC elements under direct tension

  • Jakubovskis, Ronaldas;Kupliauskas, Rimantas;Rimkus, Arvydas;Gribniak, Viktor
    • Structural Engineering and Mechanics
    • /
    • v.68 no.3
    • /
    • pp.345-358
    • /
    • 2018
  • Heterogeneous structure and, particularly, low resistance to tension stresses leads to different mechanical properties of the concrete in different loading situations. To solve this problem, the tension zone of concrete elements is reinforced. Development of the cracks, however, becomes even more complicated in the presence of bar reinforcement. Direct tension test is the common layout for analyzing mechanical properties of reinforced concrete. This study investigates scatter of the test results related with arrangement of bar reinforcement. It employs results of six elements with square $60{\times}60mm$ cross-section reinforced with one or four 5 mm bars. Differently to the common research practice (limited to the average deformation response), this study presents recordings of numerous strain gauges, which allows to monitor/assess evolution of the deformations during the test. A simple procedure for variation assessment of elasticity modulus of the concrete is proposed. The variation analysis reveals different deformation behavior of the concrete in the prisms with different distribution of the reinforcement bars. Application of finite element approach to carefully collected experimental data has revealed the effects, which were neglected during the test results interpretation stage.

Cooling and Heating Load Analysis According to Building Type of Apartment House (공동주택의 주동 유형별 냉난방부하 분석)

  • Yoon, Sung-Meen;Lee, Kyung-Hee;Ahn, Young-Chull;Kim, Yong-Tae
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.45-50
    • /
    • 2014
  • This study focuses on the analysis of the cooling and heating load in accordance with apartment houses arrangement type using Ecotect Analysis. Korea have to reduce energy consumption part of building except in industry and transport because the rate of dependence on imports amounts to 94%, Apartment houses built in various forms in order to reduce energy are modelled in each window area ratio, shape, orientation, and climate through simulation. Through this study, we can analyze the cooling and heating load by form, window area ratio, orientation, and climate change and know the optimal elements by the form. In particular, although there have been done research on the window area ratio and the arrangement form, the research of the regional climate characteristics and the direction are hardly carried out. To supplement those problem, adding to seven direction and climatic element of southern region is characteristic(L Type, Y Type, - Type) of this study. The form of apartment houses built 10 years ago is modelled for simulation.

The acrosswind response of the downwind prism in a twin-prism system with a staggered arrangement

  • Fang, Fuh-Min;Chung, Cheng-Yang;Li, Yi-Chao;Liu, Wen-Chin;Lei, Perng-Kwei
    • Wind and Structures
    • /
    • v.17 no.3
    • /
    • pp.245-262
    • /
    • 2013
  • The flow interaction between two identical neighboring twin square prisms in a staggered arrangement in an open terrain was investigated experimentally. The downwind prism was mounted on a rigid-aeroelastic setup in an open-terrain boundary layer flow to measure its acrosswind root-mean-square responses and aerodynamic damping ratios. By varying the relative location of the upwind prism and the Scruton number associated with the downwind prism, the acrosswind aeroelastic behavior of the downwind prism was analyzed and compared to that of an isolated one. Results showed that the acrosswind root-mean-square response of the downwind prism could be either suppressed or enhanced by the wake flow produced by the neighboring upwind prism. Besides the assessment of the wake effect of the downwind prism, finally, regressed relationships were presented to describe the variation of the aerodynamic damping ratio so as to predict its acrosswind fluctuating response numerically.

Mechanical behavior test and analysis of HEH sandwich external wall panel

  • Wu, Xiangguo;Zhang, Xuesen;Tao, Xiaokun;Yang, Ming;Yu, Qun;Qiu, Faqiang
    • Advances in concrete construction
    • /
    • v.13 no.2
    • /
    • pp.153-162
    • /
    • 2022
  • Prefabricated exterior wall panel is the main non-load-bearing component of assembly building, which affects the comprehensive performance of thermal insulation and durability of the building. It is of great significance to develop new prefabricated exterior wall panel with durable and lightweight characteristics for the development of energy-saving and assembly building. In the prefabricated sandwich insulation hanging wall panel, the selection of material for the outer layer and the arrangement of the connector of the inner and outer wall layers affect the mechanical performance and durability of the wall panels. In this paper, high performance cement-based composites (HPFRC) are used in the outer layer of the new type wall panel. FRP bars are used as the interface connector. Through experiments and analysis, the influence of the arrangement of connectors on the mechanical behaviors of thin-walled composite wall panel and the panel with window openings under two working conditions are investigated. The failure modes and the role of connectors of thin-walled composite wallboard are analyzed. The influence of the thickness of the wall layer and their combination on the strain growth of the control section, the initial crack resistance, the ultimate bearing capacity and the deformation of the wall panels are analyzed. The research work provides a technical reference for the engineering design of the light-weight thin-walled and durable composite sandwich wall panel.