• 제목/요약/키워드: Bubble velocity

검색결과 250건 처리시간 0.032초

고주파 삼각파 여자법을 사용한 실시간 슬러그 유동 측정용 전자기유량계 (A Real-Time Measurement of Slug Flow Using Electromagnetic Flowmeter with High frequency Triangular Excitation)

  • 안예찬;차재은;김무환
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1570-1577
    • /
    • 2002
  • In order to investigate the characteristics of two-phase slug flow, an electromagnetic flowmeter with 240Hz triangular AC excitation was designed and manufactured. The signals and noise from the flowmeter were obtained, and analyzed in comparison with the observations with a high speed CCD camera. The uncertainty of the flowmeter under single-phase flow was $\pm$ 2.24% in real-time. For two-phase slug flow, electromagnetic flowmeter provided real-time simultaneous measurements of the mean film velocity around Taylor bubble and the relative location and the length of the bubble. Besides, it is an easier and cheaper method for measuring mean film velocity than others such as photochromic dye activation method or particle image velocimetry.

댐 붕괴흐름의 해석해(Ritter의 해)를 이용한 월파유속 분석 (Analyses of Overtopping Velocity using Analytical Solution(Ritter's Solution) of Dam-Break Flow)

  • 유용욱;이종인;김영택
    • 한국수자원학회논문집
    • /
    • 제41권7호
    • /
    • pp.669-679
    • /
    • 2008
  • 본 연구는 수리실험으로 얻어진 권파에 의한 월파수괴의 유속을 댐붕괴흐름과 비교하여 거동의 유사성을 검토하였다. 댐붕괴흐름은 해석해가 간략하고 월파 거동과 유사함으로 인해 월파의 유속산정에 이용되어왔다. 월파는 일반적으로 많은 연행기포로 인해 기존의 유속측정기법을 적용하는데 제한을 받게 되므로, 본 실험에서는 기포나 기포조직모양을 이용한 기포영상유속계를 이용하여 월파 유속을 측정하였다. 실험결과로부터 월파의 유속단면을 검토하였고, 단면의 최대유속과 수심평균유속을 댐붕괴흐름의 1차원 해석해인 Ritter의 해와 비교하였다. 해석해와의 비교를 위해 댐붕괴 전 초기수심을 파랑조건과 월파의 측정값으로부터 유도하였다. 파랑조건으로부터 추정된 붕괴 전 초기 수심을 이용한 해석해는 측정된 유속의 분포형태에 있어서는 차이를 보였으나, 월파수괴의 전면속도로부터 산정된 초기수심을 이용한 해석해는 유속크기의 비교에서 좋은 일치를 보였다.

나비아-스톡스 방정식의 해에 의한 황산용액 내에서 초음파에 의해 가진되는 기포의 거동 예측 (Prediction of Behavior for an Ultrasonically Driven Bubble in Sulfuric Acid Solutions by a Set of Solutions of Navier-Stokes Equations)

  • 김기영;변기택;곽호영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.353-356
    • /
    • 2006
  • A set of solutions of the Navier-Stokes equation for the gas inside a spherical bubble with heat transfer through the bubble wall permits to predict correctly behavior of an ultrasonically driven bubble in aqueous solutions of sulfuric acid. Calculation results of the minimum velocity of bubble wall and the peak temperature and pressure are in excellent agreement with the observed ones. Further the calculated bubble radius-time curve displays alternating pattern of bubble motion as observed in experiment.

  • PDF

Numerical simulation of gas-liquid two phase flow in micro tubes

  • Sunakawa, Hideo;Teramoto, Susumu;Nagashima, Toshio
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.341-346
    • /
    • 2004
  • Motion of a bubble inside narrow tube is numerically studied. The numerical code assumes axi-symmetric incompressible flow field. The surface of the bubble is captured by VOF (Volume Of Fluid) method, and it is advected by MARS (Multiphase Advection and Reconstruction Scheme). Air bubble inside water is first studied, and it was found that a strong vortex, which is induced by the pressure difference caused by the surface tension, is formed at the rear part of the bubble. Then flow parameters are parametrically varied to understand the correlation between the bubble shape, the bubble velocity, and the flow parameters. The parametric study revealed that the aspect ratio of the bubble mainly depends on We number, and the oscillation of the bubble speeds is dependent on Re number.

  • PDF

기포-자유표면 상호작용에 대한 수치적 고찰 (Numerical Simulation of Bubble-Free Surface Interaction)

  • 양찬규;김현주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 춘계 학술대회논문집
    • /
    • pp.48-57
    • /
    • 1999
  • This paper deals with the numerical simulation of the behavior of single bubble rising near the free surface. Volume fraction of fluid (VOF) method with continuum surface force (CSF) model, the well known method for two phase flow simulation is adopted. A bubble of spherical shape positioned beneath the free surface is assumed at the initial stage. The difference according to the fluid properties of surrounding medium is examined. Simulation results are depicted and explained with the time history of bubble shape, velocity field and vorticity distribution.

  • PDF

사각 마이크로 채널 내 Taylor 유동 특성 예측에 대한 연구 (Prediction of Two-phase Taylor Flow Characteristics in a Rectangular Micro-channel)

  • 이준경;이관근
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.557-566
    • /
    • 2015
  • 본 논문에서는 $600{\times}600{\mu}m$ 사각 마이크로 채널에서의 기-액체 테일러(슬러그) 흐름의 특성을 실험을 통해 살펴보았다. 실험 유체로는 질소와 물을 사용하였으며, 액체 및 기체 겉보기 속도는 각각 0.01 ~ 3 m/s, 0.1 ~ 3 m/s 의 범위에서 테일러 흐름이 나타나는 구간에서만 데이터를 얻었다. 기포 길이, 액체 슬러그 길이, 기포 속도 그리고 기포 생성 주파수를 고속 카메라를 사용하여 이미지 분석을 통해 측정하였다. 제시된 측정값(기포 길이, 액체 슬러그 길이, 기포 속도)과 이전 문헌에서 제안된 경험적 모델의 비교결과 대부분 오차가 50% 이상으로 나타났다. 따라서 기포와 액체 슬러그 길이 그리고 기포 속도에 대한 개선된 모델을 제시하였고, ${\pm}20%$ 이내의 비교적 우수한 결과를 볼 수 있었다. 또한 기포 생성 주파수는 기포 길이, 액체슬러그 길이 그리고 기포 속도의 관계를 이용하여 ${\pm}20%$ 이내에서 예측가능함을 알 수 있었다.

수중 내 발포성 정제로부터 생성된 미세기포 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Microbubbles Generated by an Effervescent Tablet in Water)

  • 명재원;맹주영;김영준;조경민;이웅희;김성호;박영철;손영구;신원규
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.84-91
    • /
    • 2021
  • Effervescent tablets generate gas bubbles when chemical reaction occurs between water and tablets. Most of previous studies have been focused on pharmaceutical characteristics of tablets. However, for their applications in disinfectants, cleaners, and pesticides, physical characteristics of bubbles released from the effervescent tablets when they are in water are important. In this study, we experimentally investigated the characteristics of microbubbles generated by an effervescent tablet made of sodium bicarbonate and tartaric acid using PDPA and high-speed camera. Microbubbles were generated using different weights of effervescent tablet as well as in different water temperature. The experimental study shows increase in reaction time, bubble concentration and rise velocity as the weight of effervescent tablet increases from 1 to 20 g. The decrease in average bubble diameter was observed when the temperature of water increased from 25 to 45 ℃. Further, reaction time varies inversely with increase in water temperature, while bubble rise velocity is directly proportional to increase in water temperature. Effervescent table continuously generates the bubble with approximately constant diameter (235 ㎛) in the water. However, bubble concentration and bubble rise velocity decreased over time.

Velocity Field Masking Technique for Coastal Engineering Experiments

  • Adibhusana, Made Narayana;Ryu, Yong-Uk
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.154-154
    • /
    • 2021
  • Since the development of Bubble Image Velocimetry (BIV) technique as the complementary technique of Particle Image Velocimetry (PIV), the application of digital imaging technique in the field of hydraulic and coastal engineering increased rapidly. BIV works very well in multi-phase flow (air-water) flows where the PIV technique doesn't. However, the velocity field obtained from BIV technique often resulted in a velocity vector on the outside of the flow (false velocity) since the Field of View (FOV) usually not only cover the air-water flow but also the area outside the flow. In this study, a simple technique of post processing velocity field was developed. This technique works based on the average of the pixel value in the interrogation area. An image of multi-phase flow of wave overtopping was obtained through physical experiment using BIV technique. The velocity calculation was performed based on the similar method in PIV. A velocity masking technique developed in this study then applied to remove the false velocity vector. Result from non-masking, manually removed and auto removed false velocity vector were presented. The masking technique show a similar result as manually removed velocity vector. This method could apply in a large number of velocity field which is could increase the velocity map post-processing time.

  • PDF

TLC 비접촉 온도측정과 중력장에서 열모세관 현상 구명 (A Measurement of Temperature by TLC without Contact and A Study of Thermocapillary Flow under Ground-based Conditions)

  • 엄용균;유재봉
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1071-1075
    • /
    • 2003
  • In a closed square cavity filled with a liquid, a cooled the upper horizontal wail and a heated the lower horizontal wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In such case the flow phenomena near an air bubble under a cooled horizontal wall were investigated. The temperature and the flow fields were studied by using the Thermo-sensitive Liquid-Crystal and the image processing. The qualitative analysis for the temperature and the flow fields were carried out by applying the image processing technique to the original data. Injecting bubble at the center point of upper cooled wall, the symmetry shape of two vortexes near an air bubble was observed. The bubble size increased, the size of velocity and the magnitude of velocity increased. In spite of elapsed time, a pair of two vortexes was the unique and steady-state flow in a square cavity and wasn't induce to the other flow in the surround region.

  • PDF

Generation of sub-micron (nano) bubbles and characterization of their fundamental properties

  • Kim, Sangbeom;Kim, Hyoungjun;Han, Mooyoung;Kim, Tschungil
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.382-388
    • /
    • 2019
  • Although nanobubbles attract significant attention, their characteristics and applications have not been thoroughly defined. There are diverse opinions about the definition of nanobubbles and controversy regarding methods that verify their characteristics. This study defines nanobubbles as having a size less than $1{\mu}m$. The generation of these sub-micron (nano) bubbles may be verified by induced coalescence or light scattering. The size of a sub-micron (nano) bubbles may be measured by optical, and confocal laser scanning microscopy. Also, the size may be estimated by the relationship of bubble size with the dissolved oxygen concentration. However, further research is required to accurately define the average bubble size. The zeta potential of sub-micron (nano) bubbles decreases as pH increases, and this trend is consistent for micron bubbles. When the bubble size is reduced to about 700-900 nm, they become stationary in water and lose buoyancy. This characteristic means that measuring the concentration of sub-micron (nano) bubbles by volume may be possible by irradiating them with ultrasonic waves, causing them to merge into micron bubbles. As mass transfer is a function of surface area and rising velocity, this strongly indicates that the application of sub-micron (nano) bubbles may significantly increase mass transfer rates in advanced oxidation and aeration processes.