• Title/Summary/Keyword: Bubble test

Search Result 206, Processing Time 0.027 seconds

Effect of Boundary Layer Thickness on the Flow Characteristics around a Rectangular Prism (직사각형 프리즘 주위의 유동특성에 대한 경계층 두께의 영향)

  • Ji, Ho-Seong;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.306-311
    • /
    • 2001
  • Effect of boundary layer thickness on the flow characteristics around a rectangular prism has been investigated by using a PIV(Particle Image Velocimetry) technique. Three different boundary layers(thick, medium and thin)were generated in the Atmospheric Boundary Layer Wind Tunnel at Pusan National University. The thick boundary layer having 670mm thickness was generated by using spires and roughness elements. The medium thickness of boundary layer$(\delta=270mm)$ was the natural turbulent boundary layer at the test section with fully long developing length(18m). The thin boundary layer with 36.5mm thickness was generated by on a smooth panel elevated 70cm from the wind tunnel floor. The Reynolds number based on the free stream velocity and the height of the model was $7.9{\times}10^3$. The mean velocity vector fields and turbulent kinetic energy distribution were measured and compared. The effect of boundary layer thickness is clearly observed not only in the length of separation bubble but also in the reattachment points. The thinner boundary layer thickness, the higher turbulent kinetic energy peak around the model roof. It is strongly recommended that the height ratio between model and approaching boundary layer thickness should be a major parameter.

  • PDF

Experimental Study of the Ultrasonic Vibration Effects on CHF Occurring on Inclined Flat Surfaces (초음파 진동이 경사진 평판에서의 CHF에 미치는 영향에 대한 실험연구)

  • 정지환;김대훈;권영철
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.139-144
    • /
    • 2003
  • Augmentation of CHF by ultrasonic vibration in water pool is experimentally investigated under pool boiling condition. The experiments are carried out using copper coated plates and distilled water. Measurements of CHF on flat plate heated surface were made with and without ultrasonic wave and with variations in inclined angle of the surface and water subcooling. Experimental apparatus consists of a bath, power supply, test section, ultrasonic generator, and data acquisition system. The measurements show that ultrasonic wave enhances CHF and its extent is dependent upon inclination angle as well as water subcooling. The rate of increase in CHF increases with an increase in water subcooling while it decreases with an increase in inclination angle. Visual observation shows that the cause of CHF augmentation is closely related with the dynamic behavior of bubble generation and departure in acoustic field.

An Adaptive Network Double Buffer Model for Efficient Memory Resource Usage (메모리 자원 사용 효율성 증진을 위한 적응적 네트워크 이중 버퍼 모델)

  • Choi, Daniel;Lee, Sung-Young
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.11
    • /
    • pp.810-819
    • /
    • 2006
  • This paper proposes an Adaptive Double Buffer Model. As a new FIFO buffer model, this technique minimizes packet losses from network congestion by logically managing buffers. It allocates the spare spaces of non-congested buffers to congested buffers by allowing receive/send buffers to share two queues, and hence it minimizes packet losses. In contrast to the buffer model utilizing a free list, this buffer model can prevent the bubble phenomenon caused by a memory leak and thereby apply to a network buffer in a restricted environment. Also, compared with the model using an way, this model brings maximum 100 percent improvement in accepting packets and compared with the model utilizing a free list, this model has the similar efficiency Results of the performance test on Adaptive Double Buffer Model, shows that this proposed model decreases packet losses and enhances memory efficiency.

Effect of Various Shapes of Mixer Geometry on Two-Phase Flow Patterns in a Micro-Channel (마이크로 채널 내 혼합부 형상이 2상 유동 양식에 미치는 영향에 대한 연구)

  • Lee, Kwan Geun;Lee, Jun Kyoung;Park, Taehyun;Kim, Gyo Nam;Park, Eun Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.75-80
    • /
    • 2015
  • The effect of inlet mixer geometries on the two-phase flow patterns in square micro-channel with $600{\times}600{\mu}m$ was investigated experimentally in this paper. The 4 different mixer configurations based on the Y, Impacting, and two T types (gas and liquid inlets were switched) were used. The test fluids were nitrogen and water. The liquid and gas superficial velocities were 0.01~10 m/s and 0.1~100 m/s, respectively. Several distinctive flow patterns, namely, annular, slug-annular, slug, slug-bubbly, bubbly, and churn flow could be seen. The flow pattern maps for each mixer were suggested, and it can be concluded that two-phase flow patterns are not very sensitive to the mixer geometries. But the mixing behaviors of gas and liquid for each mixer were different for slug and bubbly flow. Thus, the characteristics of slug and bubble for each case were not same.

Study on the Fugitive Emissions of a PFA Lined Ball Valve through Helium Leak Detection (PFA 라이닝 볼밸브의 헬륨누설 검출 및 비산배출에 관한 연구)

  • Lee, Won-Ho;Kim, Dong-Yeol;Lee, Jong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.4
    • /
    • pp.39-42
    • /
    • 2016
  • A PFA lined ball valve, which is machined with fluorinated resin PFA to its inner part for improving corrosion resistance, non-stickness, heat-resistance, has been widely used to the chemical/pharmaceutical industries, the semiconductor/LCD manufacturing processes, etc. with the high purity chemicals as working fluid. EPA stated that 60% of all fugitive emissions come from the valve stem packing in a typical petroleum or chemical processing plant. They monitor regulated components for leaks and maintain seal performance at acceptable levels. Korean industrial standards only deals with the bubble test for in-line leakage of valves, which has the detectable leak rate of $10^{-4}$ [$mbar{\cdot}L{\cdot}s^{-1}$], therefore, it is not sufficient to check fugitive emissions. In this study, we conducted Helium leak detection from a PFA lined ball valve and evaluated fugitive emissions according to ISO 15848-1, which has the detectable leak rate of $10^{-9}$ [$mbar{\cdot}L{\cdot}s^{-1}$], for manufacturing the high-reliable PFA lined ball valves against fugitive emissions.

Effects of Carbon Fiber on Mechanical Behaviour of Al2O3 Porous Ceramics

  • Basnet, Bijay;Lim, Hyung Mi;Lee, Kee Sung;Kim, Ik Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.5
    • /
    • pp.513-520
    • /
    • 2019
  • This study reports the improvement of mechanical properties of Al2O3 porous ceramics from colloidal suspension with the addition of carbon fiber by direct foaming. The initial colloidal suspension of Al2O3 was partially hydrophobized by surfactant to stabilize wet foam with the addition of carbon fiber from 2 to 8 wt% as stabilizer. The influence of carbon fiber on the air content, bubble size, pore size and pore distribution in terms of wet foam stability and physical properties of porous ceramics were discussed. The viscosity of the colloidal suspension was increased giving solid like properties with the increased in carbon fiber content. The mechanical properties of the sintered porous samples were investigated by Hertzian indentation test. The results show the wet foam stability of more than 90% corresponds to compressive loading of 156.48 N and elastic modulus of 57.44 MPa of sintered sample with 8 wt% of carbon fiber content.

Study of Effectiveness of using higher voltages in analysis of dredged sediments and heavy metal concentration (고전압 이용한 준설퇴적토 유효성 및 중금속 변화에 관한 연구)

  • Kwon, Ki-Bum;Kim, Sang-Keun;Ramchanda, Prasad;Yu, Jun;Chung, Ha-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1446-1451
    • /
    • 2008
  • The clay found in the river or in any waste water treatment plant usually have a very high content of water. A large amount of sediments hinder the navigation in river. In waste water treatment plant, there is requirement of settling the thick sludge. These problems are overcome by using rapid means of sedimentation and settling. This paper focus on how method of Electrokinetic sedimentation can be made faster. Sedimentation using Electrokinetic phenomenon has been discussed with varied voltage applied and effect and dose of coagulant in increasing the process. The experimental test has been carried out at water content that are generally present in the case of river and small canals carrying waste water. This paper also focus on different heavy metals concentration during the process and the power aspects of process. A series of experiment were done to support the proposed theory and how a bubble formation could hinder the purpose of experiment.

  • PDF

An experimental evaluation of hardened property of concrete using early-strength-binder with curing temperature (조강형 결합재를 사용한 콘크리트의 양생온도에 따른 경화특성 실험적 평가)

  • Kim, Kwang-Ki;Kim, Young-sun;Lee, Joo-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.88-89
    • /
    • 2015
  • In cold weather, the speed of concrete strength development is slow. As a result, construction speed becomes slow and it is problem for all construction site to solve this. So in this study, to shorten removing frame time after placing concrete, mix proportion using early-strength-binder(ESB) and curing method such as using heat line in concrete was considered. At first, concrete mix proportion was examined at -5℃ temperature between ordinary portland cement(OPC) and ESB. And second step, concrete, using mix proportion with OPC, was examined according to curing method(: 1) heat line used and 2) no heat line) and kinds of form (: 1) Deck slab, 2) Half PC slab and 3) SOG slab). All cases are same condition: slab thickness is 1,500mm, double-bubble sheet is used as a curing sheet after placing concrete. After the test, OPC is enough to get strength compared to ESB in special condition and 48~60 hours is needed according to form condition.

  • PDF

A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Shin, Min-Ho;Hwang, Kyeong-Mo;Kim, Kyung-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2017-2022
    • /
    • 2004
  • There are multistage preheaters in the power generation plan to improve the thermal efficiency of the plant and to prevent the components from the thermal shock. The energy source of these heaters comes from the extracted two phase fluid of working system. These two-phase fluid can cause the so-called Flow Accelerated Corrosion(FAC) in the extracting piping and the bubble plate of the heater for example, in case of point Beach Nuclear Power Plant and in the Wolsung Nuclear Power Plant. The FAC is due to the mass transport of the thin oxide layer by the convection. FAC is dependent on many parameters such as the operation temperature, void fraction, the fluid velocity and pH of fluid and so on. Therefore, in this paper velocity was calculated by FLUENT code in order to find out the root cause of the wall thinning of the feedwater heaters. It also includeed in the fluid mixing analysis model are around the number 5A feedwater heater shell including the extraction pipeline. To identify the relation between the local velocities and wall thinning, the local velocities according to the analysis results were compared with distribution of the shell wall thicknes by ultrasonic test.

  • PDF

Effect of Peak Temperatures on Hydrogen Attack Susceptibility in Simulated Weld Heat Affected Zone of 3Cr-1Mo-V Steel (3Cr-1Mo-V강의 재현 열영향부에서 최고가열온도가 수소침식감수성에 미치는 영향)

  • 김동진;김병훈;공병욱;김정태;권용형;박화순;강정윤
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.232-232
    • /
    • 2000
  • The hydrogen attack characteristics of 3Cr-1Mo-V steel as simulated weld heat affected state were studied in this paper. The hydrogen attack susceptibility was evaluated by the ratios of Charpy impact absorbed energy at 0℃($vE_{0HA}$/$vE_{0}$) and reduction of area by tensile test ($RA_{HA}$/RA) before and after exposure to hydrogen at 600℃ under 450kgf/㎠ for 300hr. The values of $vE_{0HA}$/$vE_{0}$ and $RA_{HA}$/RA were aggravated as the peak temperature of the simulated heat affected zone(HAZ) raised. These results were due to the increase of the possession of bubbles along the grain boundaries, which were resulted in the reduction of grain boundary area to be precipitated carbides due to grain coarsening and the carbon dissolved in the martensite-austenite constituent near by the prior austenite grain boundary. The possession ratio of methane bubbles formed along prior austenite grain boundaries were increased with raising the peak temperature. (Received February 22, 2000)