• Title/Summary/Keyword: Bubble test

Search Result 206, Processing Time 0.026 seconds

Computation of Supersonic Ramp Flow with V2F Turbulence Mode (V2F 난류모형을 이용한 초음속 램프유동의 해석)

  • Park C. H.;Park S. O.
    • Journal of computational fluids engineering
    • /
    • v.8 no.2
    • /
    • pp.1-7
    • /
    • 2003
  • The V2F turbulence model, which has shown very good performance in several test cases at low speeds, has been applied to supersonic ramp flow with 20. corner angle at the free stream Mach number of 2.79. The flow is known to manifest strong shock wave/turbulent boundary layer interactions. As a comparative study, low-Reynolds k-ε models are also considered. While the V2F model predicts wall-pressure distribution well, it relatively predicts larger separation bubble and higher skin-friction after the reattachment than the experimental data. Although the ellpticity of f equation is the characteristics of incompressible flows, the converged solutions are acquired in the compressible flow with shock waves. The effect of the realizability constraints used in the model is also examined. In contrast to the result of impinging jet flows, the realizability bounds proposed by Durbin deterioate the overall solutions of the supersonic ramp flow.

Reclamation of Waste Lubricating Oil Using Ceramic Composite Membranes (세라믹 복합막을 이용한 폐윤활유 재생)

  • 현상훈;김계태
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.59-59
    • /
    • 1996
  • 막분리에 의한 폐윤활유 재생공정을 개발하기 위한 기초 연구로써 폐윤활유 분리/재생용으로 적합한 복층(multilayer)세라믹 복합막의 제조와 합성막의 폐유 분리 효율등이 연구되었다. 결함이 없고 두께가 균일한 지르코니아 복합막 (기공크기 0.07 $\mu$m 이하)은 압출 성형법으로 제조한 튜브형 $\alpha$-알루미나 담체 (외경 7.8 mm, 두께 0.6 mm, 기공크기 0.7 $\mu$m)내부표면에 역침지 인상법(reverse dip-drawing technique)에 의하여 지르코니아 슬러리를 코팅 한 후 950$\circ$C에서 1시간 열처리하여 제조 되었다. 또한 지르코니아 복합막 위에 니타니아 졸-겔 코팅을 한 후 450$\circ$C에서 2시간 열처리하여 기공크기가 15 nm정도인 3층 복합막을 제조 하였다. SEM, Bubble Point Test, Mercury Porosimeter 그리고 분획 분자량 측정등에 의하여 복합막의 코팅층 두께, 결함유무 및 막의 기공크기등을 분석하였다.

  • PDF

A Numerical Analysis of Internal Nozzle Flows Through the Multi-Fluid Model (다유체 모델을 이용한 노즐 내부 유동에 대한 수치적 연구)

  • Ryu, Bong-Woo;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.16 no.4
    • /
    • pp.186-194
    • /
    • 2011
  • This study performed the numerical analysis of the internal nozzle flows including cavitation phenomena by using the automated body-fitted grid generator and the multi-fluid model. The effect of grid refinement and the validation of multifluid model were investigated using four computational meshes under two test conditions. The mesh #3 was chosen as the optimum which can reduce the computational time and have good prediction ability to identify the cavitation region simultaneously. In addition, the computed results using multi-fluid model were compared with the reference experimental observations and numerical simulation results using homogeneous equilibrium model. From the distribution of volume fraction and velocity field, the multi-fluid model predicted the internal nozzle flows well when the liquid quality parameters were selected as $1.0{\times}10^{12}$ for initial number density and 25 ${\mu}m$ for bubble diameter.

Effect of Liquid Subcooling on Pool Boiling Heat Transfer in Vertical Annuli with Closed Bottoms (액체과냉도가 하부폐쇄 수직환상공간 내부의 풀비등 열전달에 미치는 영향)

  • Kang Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.239-246
    • /
    • 2005
  • Effects of subcooling on pool boiling heat transfer in vertical annuli with closed bottoms have been investigated experimentally. For the test, a tube of 19.1mm diameter and the water at atmospheric pressure have been used. Three annular gaps of 7.05, 18.15, and 28.20 have been tested in the subcooled water and results of the annuli are compared with the data of a single unrestricted tube. The increase in pool subcooling results in much change in heat transfer coefficients. At highly subcooled regions, heat transfer coefficients for the annuli are much larger than those of a single tube. As the heat flux increases and subcooling decrease, a deterioration of heat transfer coefficients is observed at the annulus of 7.05mm gap. Single-phase natural convection and liquid agitation are the governing mechanisms for the single tube while liquid agitation and bubble coalescence are the major factors at the bottom closed annuli.

Maximum Likelihood Classifier Using Detection of Amplitude Modulation Frequency due to Propulsion of Underwater Vehicle (수중 프로펠러 추진체에 의한 진폭변조 신호의 주파수 탐지에 의한 Maximum Likelihood Classifier)

  • 강성현;김의준;윤원식
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.8
    • /
    • pp.47-53
    • /
    • 2000
  • In order to classify the underwater vehicles due to propeller propulsion, maximum likelihood classifier was developed. Propeller produces the cavitation and noise during its work. Cavitation-bubble makes the nonlinear medium in the water. The nonlinearity of cavitation leads to the generation of a complete spectrum of combination harmonics of the tonals of noise, and modulation of cavitation noise with propeller shaft-rates and blade-rates. The optimal estimator was derived mathematically and its capabilities were proven by simulation and real test.

  • PDF

A Study on a VOF Method for Improved Free Surface Capturing (VOF법의 자유수면 포착정도 향상을 위한 연구)

  • Park Il-Ryong;Kim Wu-Joan;Kim Jin;Van Suak-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.202-206
    • /
    • 2005
  • A new numerical scheme for two-phase flows, the Hybrid VOF method has been developed for improved free surface capturing. The present new method is a volume capturing based VOF method coupled with a reinitialization procedure of a Level-set method. For validation, the proposed method is applied to two test cases: spherical bubble rising and dam breaking. The calculated results by using the Hybrid VOF method with the two previously applied VOF formulations are compared with available numerical and experimental data. It is found that the new method provides more accurate results than the two previous ones.

  • PDF

NUMERICAL ANALYSIS OF MULTIPHASE FLOW BY NUFLEX (NUFLEX의 다상유동 해석)

  • Son, Gi-Hun;Suh, Young-Ho;YU, Tae-Jin;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.95-98
    • /
    • 2007
  • A general purpose program NUFLEX has been extended for two-phase flows with topologically complex interface and cavitation flows with liquid-vapor phase change caused by large pressure drop. In analysis of two-phase flow, the phase interfaces are tracked by employing a LS(Level Set) method. Compared with the VOF(Volume-of-Fluid} method based on a non-smooth volume-fraction function, the LS method can calculate an interfacial curvature more accurately by using a smooth distance function. Also, it is quite straightforward to implement for 3-D irregular meshes compared with the VOF method requiring much more complicated geometric calculations. Also, the cavitation process is computed by including the effects of evaporation and condensation for bubble formation and collapse as well as turbulence in flows. The volume-faction and continuity equations are adapted for cavitation models with phase change. The LS and cavitation formulation are implemented into a general purpose program for 3-D flows and verified through several test problems.

  • PDF

Tip-less PDP Vacuum In-Line Sealing Technology by Bubble-Reduced Frit along an Auxiliary Heating Line

  • Kwon, Sang-Jik;Yang, Hwi-Chan;Lee, Myung-Sik;Whang, Ki-Woong;Jung, Dong-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.643-646
    • /
    • 2002
  • Sealing of two glass plates composing of PDP panel was done in a vacuum chamber by using an auxiliary heating line(AHL). In order to improve the uniformity of sealing temperature and reduce the panel temperature during sealing, the AHL was introduced by a screen printing method inside a frit glass and used as a part of heating source for the frit melting. By using the AHL technology and the specially prepared frit glass, we have successfully sealed a PDP test panel without bubbles and any leak through the frit glass.

  • PDF

Studies on the flow stabilization around the turbine suction with utilizing the surface water overflow at small-hydraulic power plant (표층수의 월류를 통한 소수력빌전소 수차터빈측의 유동안정화 연구)

  • Lee, Sungmyung;Kim, Cheolhan;Yoo, Gunjong;Kim, Wonseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.165.2-165.2
    • /
    • 2011
  • Flow with suction to water turbine must be in stable state at small hydraulic power plant. But because of water level fluctuation and water gate effect according to irregular supply of cooling water, it would happen to produce bubble and vortex and finally lead to problems in power-plant system. With utilizing the concept design of double size gate, surface water overflowed the overhead of gate for stable flow at suction. We developed the overflow condition and analyzed the design factor with existed one such as water level(overflow amount) and overhead of water gate(overflow figure). Flow test and CFD simulation say that flow have stable state around suction and 20% of wave reduction effect at surface layer after surface water overflow.

  • PDF

An Experimental Study on the Drag Reduction with polymer Additives in Pipe Flow System (관 유동에서 폴리머 첨가에 의한 저항감소 현상의 실험적 고찰)

  • Cha, K.O.;Kim, J.G.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.1-11
    • /
    • 1999
  • Previous researchers have studied how to reduce a pumping power in order to save energy in the fluid transporting system. Especially, it has been studied a lot about reducing the pressure drop among parameters related to the energy saving for fluid transport. This study is to investigate the effect of a substantial drag reduction caused by the polymer(A611P, A601P) when the working fluids flow to the vertical and horizontal direction in the vertical cylindrical equipment of closed flow system. In this experiment, we mount a visualization equipment on the test section and take pictures. With using the PIV system, instrument and analyzing the movement of bubble for different polymer concentration are observed and some mechanism of the drag reduction effect is clarified.

  • PDF