• Title/Summary/Keyword: Bubble flow characteristics

Search Result 167, Processing Time 0.023 seconds

A Simulation on the Two-Phase Flow Characteristics in Gas Bubble Driven Circulation Systems (Gas Bubble Driven Circulation Systems에서의 이상유동 특성의 시뮬레이션)

  • 최청렬
    • Journal of the Korea Society for Simulation
    • /
    • v.7 no.2
    • /
    • pp.17-32
    • /
    • 1998
  • The flow fields in Gas Bubble Driven Circulation Systems were numerically analyzed. In various gas flow rate and bubble size, the flow characteristics were predicted. Eulerian-Eulerian approach was used for the formulation of both the continuous and dispersed phases. The modification of the general purpose computer program PHOENICS code was employed to predict the mean flow fields, turbulent characteristics, gas dispersion, volume fraction. The predicted shows very satisfactory agreement with experimental results for all regions of ladle. The results are of interest in the design and operation of wide variety of material processing.

  • PDF

A Study on the Characteristics of Two-Phase Flow by Driven Bubbles (기포운동에 따른 2상유동 특성에 관한 연구)

  • 서동표;오율권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.268-273
    • /
    • 2003
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas is concentrated at the near nozzle, the flow parameters are high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (P.I..V) and a thermo-vision camera were used in the present study. The experimental results show that heat transfer from bubble surface to water is largely completed within z=10mm from the nozzle, and then the temperature of bubble surface reaches that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

A Study on the Characteristics of Two-Phase Flow by Driven Bubbles in a Liquid Bath

  • Oh, Yool-Kwon;Seo, Dong-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2005
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas was concentrated at the near the nozzle, the flow parameters were high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (PIV) and a thermo-vision camera were used in the present study. The experimental results showed that heat transfer from bubble surface to water was largely completed within z = 10 mm from the nozzle, and then the temperature of bubble surface reached that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

A Study on the Vertical upward Bubble Flow using Image Processing Technique (영상기법을 이용한 수직상향 기포유동에 관한 연구)

  • 서동표;오율권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.617-623
    • /
    • 2003
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. The velocity of upward bubble flow was calculated for two different experimental conditions:1) bubble flow without kinetic energy 2) bubble flow with kinetic energy. Bubble flow without kinetic energy starts to undergo the effect of buoyancy l0cm away from the nozzle. Whereas. kinetic energy is dominant before 30 cm away from the nozzle in bubble flow but after this point kinetic energy and inertial force are applied on bubble flow at the same time In addition, as the flow rate increases the maximum velocity point moves to the nozzle. The velocity Profiles near free surface is extremely irregular due to surface flow. Gas volume fraction is high near the nozzle due to gas concentration. but decreases with the increasement of axial position. Gas volume fraction does not vary after the axial position, z=60 in spite of the increasement of flow.

A Study on the Flow Characteristics of Bubbles in a Fluidized Bed (유동층에서 기포의 유동특성에 관한 연구)

  • 김용섭
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.117-124
    • /
    • 1996
  • A fluidized bed combustion chamber is widely used to incinerate waste material. The most important factor designing the incinerator is the flow characteristics in a fluidized bed, because combustion efficiency is influenced by the flow characteristics. This paper has invesitigated the flow characteristics of bubbles in fluidized bed by means of meassuring a pressure fluctuation in the fluidized bed. A pressure probe system has used to measure the pressure. The data concerned with bubble rising velocity, bubble size, distribution of bubbles and frequency of bubble generation or decay are obtained to find the flow characteristics of bubbles in the fluidized bed. The result obtained from this experimental study can be used to design the fuel feeding system of fluidized bed combustion type incinerator. And it is possible to predict the mixing of waste material and fluidizing material.

  • PDF

Two- and Three-dimensional Analysis on the Bubble Flow Characteristics Using CPFD Simulation

  • Lim, Jong Hun;Lee, Dong Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.698-703
    • /
    • 2017
  • Bubble flow characteristics in fluidized beds were analyzed by CPFD simulation. A fluidized bed, which had the size of $0.3m-ID{\times}2.4m-high$, was modeled by commercial CPFD $Barracuda^{(R)}$. Properties of bed material were $d_p=150{\mu}m$, ${\rho}_p=2,330kg/m^3$, and $U_{mf}=0.02m/s$. Gas was uniformly distributed and the range of superficial gas velocity was 0.07 to 0.16 m/s. Two other geometries were modeled. The first was a three-dimensional model, and the other was a two-dimensional model of $0.01m{\times}0.3m{\times}2.4m$. Bubble size and rising velocity were simulated by axial and radial position according to superficial gas velocity. In the case of three-dimensional model, simulated bubble rising velocity was different from correlations, because there was zigzag motion in bubble flow, and bubble detection was duplicated. To exclude zigzag motion of bubble flow, bubble rising velocity was simulated in the two-dimensional model and compared to the result from three-dimensional model.

Experimental study of bubble flow behavior during flow instability under uniform and non-uniform transverse heat distribution

  • Al-Yahia, Omar S.;Yoon, Ho Joon;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2771-2788
    • /
    • 2020
  • Experiments are conducted to study bubble flow behavior during the instability of subcooled boiling under uniform and non-uniform transverse heating. The non-uniform heat distribution introduces nonuniform bubble generation and condensation rates on the heated surface, which is different from the uniform heating. These bubble generation and condensation characteristics introduce a non-uniform local pressure distribution in the transverse direction, which creates an extra non-uniform pressure on the flowing bubbles. Therefore, different bubble flow behavior can be observed between uniform and non-uniform heating conditions. In the uniform heating, bubble velocity fluctuations are low, and the bubbles travel straight along the axial direction. In the non-uniform heating, more fluctuation in the bubble velocity occurs at low mass flow rate and high subcooled inlet temperatures, and reverse flow is observed. Additionally, the bubbles show a zigzag trajectory when they pass through the channel, which indicates the existence of cross flow in the transverse direction.

A Study on the Bubble Flow in the Gas-Liquid Plume (기-액 기둥에서 기포유동에 관한 연구)

  • Seo, Dong-Pyo;Hong, Myung-Seok;Oh, Yool-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2105-2108
    • /
    • 2003
  • The characteristics of upward bubble flow were experimentally investigated in a liquid bath. In the present study, a thermal-infrared camera and high speed CCO camera were used to measure their temperature and local rising velocity, respectively. Heat transfer from bubble surface to water is largely completed within z=10mm from the nozzle, and then the temperature of bubble surface reaches that of water rapidly. The rising velocity of bubble was calculated for two different experimental conditions: 1) bubble flow without kinetic energy 2) with kinetic energy. Bubble flow without kinetic energy starts to undergo the effect of inertia force 10cm away from the nozzle. Whereas, kinetic energy is dominant before 30 cm away from the nozzle in bubble flow, but after this point, kinetic energy and inertial force are applied on bubble flow at the same time.

  • PDF

Study on the Characteristics of Bubble and Liquid Slugs for Gas-Liquid Taylor Flow in a Rectangular Micro-channel (사각 마이크로 채널 내 Taylor Flow의 기포 및 액체 슬러그 유동 특성에 대한 연구)

  • Lee, Jun Kyoung;Lee, Kwan Geun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.520-526
    • /
    • 2015
  • The characteristics of gas-liquid Taylor (Slug) flow in a square micro-channel of $600{\sim}600{{\mu}m}$ were investigated experimentally in this paper. The test fluids were nitrogen and water. The liquid and gas superficial velocities were 0.01~3 m/s and 0.1~3 m/s, respectively. Bubble and liquid slug length, bubble velocity, and frequency were measured by analyzing optical images using a high speed camera. Bubble length decreased with higher liquid flow rate, which increased dramatically with higher gas flow rate. However, slug length did not vary with changes in inlet liquid conditions. Additionally, bubble velocities and frequencies increased with higher liquid and gas flow rates. It was found that measured bubble lengths were in good agreement with the empirical models in the existing literature, but slug lengths were not.

Study on Flow Interaction between Bubble and Phase Change Material according to Injection Location (주입 위치에 따른 기포와 상변화물질의 유동 상호 작용에 관한 연구)

  • Min Hyeok Kim;Yun Young Ji;Dong Kee Sohn;Han Seo Ko
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.3
    • /
    • pp.75-84
    • /
    • 2023
  • In this study, we conducted analysis of bubble dynamics and flow of liquid phase change material(PCM) using shadowgraphy and particle image velocimetry(PIV). Characteristics of internal flow varied depending on locations of injection when solid PCM was liquefied from heated vertical wall. When bubbles rose immediately, they exhibited elliptical shape and zigzag trajectory. In contrast, when bubbles rose after merging at the bottom of solid PCM, with equivalent diameter for the inter-wall distance of 0.64 or greater, they showed a jellyfish shape and strong rocking behavior. It was observed by the PIV that the small ellipse bubbles made most strong flow inside the liquid PCM. Furthermore, the flow velocity was highest in the case of front injection, as the directions of temperature gradients and bubble-driven flow were aligned. The results underscore the significant influence of injection location on various characteristics, including bubble size, shape, rising path of bubbles, and internal flow.