• Title/Summary/Keyword: Bubble departure diameter

Search Result 13, Processing Time 0.02 seconds

Improved Heat Transfer Coefficient in Heat Exchanger by the Use of Specialized Heating Surface (전열면의 특수표면화에 의한 열기기의 효율향상에 관하여)

  • Yim, Chang-Soon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.8 no.3
    • /
    • pp.131-150
    • /
    • 1979
  • Recently only a few correlations between various factors due to the different grades of surface roughness for the nucleate pool boiling have been proposed. The main purpose of this work is to test the validity of these types of correlations between related factors to nucleate pool boiling phenomena. The boiling experiments using distilled water were carried out at the heat flux ranging from $7.4\times10^4\;to\;2.4\times10^5kcal/m^2h$ on the sintered porous metal surface with the cavity diameter of 10, n, 40, 70, $100{\mu}$, respectively, at the atmospheric pressure, To determine the bubble sizes, number of nucleation sites, delay and growth time, frequency of bubble emission and rising velocities of bubbles, the high speed motion picture technique was employed. In the correlation $f{\propto}D_b^n$, where f denotes frequency of bubble emission and $D_b$ departure diameter, n, the power factor of $D_b$, have been found to be from -2 to -10/3. The correlation C in the correlation between heat flux q and density of nucleation sites $\frac{N}{A}$, $q=C(\frac{N}{A})^n$, was appeared to be more crucial than the power factor n. The correlation of the heat flux q to the temperature difference ${\Delta}T$ and the density of nucleation sites$\frac{N}{A}$, was proposed to be $$q-460{\Delta}T^{\frac{5}{4}}=K{\Delta}T{\frac{5}{3}}(\frac{N}{A})^{\frac{2}{3}}$$. The values of heat transfer coefficient obtained in this experiments for the porous sintered metal surface appeared to be very high in comparison with the formerly obtained results for the other surfaces.

  • PDF

An Experimental Study on the Effect of Low Fin Tube Geometry on Pool Boiling of a LiBr Solution (낮은 핀관의 형상이 LiBr 수용액의 풀 비등에 미치는 영향에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.591-598
    • /
    • 2015
  • Pool boiling heat transfer coefficients of a LiBr solution were obtained for seven low fin tubes having different fin pitch and fin height. The test range covered saturation pressure from 7.38kPa to 101.3kPa, heat flux from $20kW/m^2$ to $40 kW/m^2$ and LiBr concentration from 0% to 50%. The optimum fin geometry for the present experimental range turned out to be 26 fpi with 0.18 mm fin height.The advantage of added heat transfer area and the disadvantage of slower bubble growth and departure appear to have yielded an optimum fin pitch. The heat transfer coefficient decreased as saturation pressure decreased and Libr concentration increased. The reason may be attributed to the low saturation pressure, which increased the bubble departure diameter and decreased the bubble departure frequency. As the LiBr concenreation increased, the saturation temperature increased and the mass diffusion rate decreased, which resulted in a reduced heat transfer coefficient. The heat transfer coefficients of the low fin tube were greater than those of the smooth tube. Correlations were developed based on the present data.

Experimental Study on Heat Flux Partitioning in Subcooled Nucleate Boiling on Vertical Wall (수직 벽면에서 과냉 핵비등 시 열유속 분배에 관한 실험적 연구)

  • Song, Junkyu;Park, Junseok;Jung, Satbyoul;Kim, Hyungdae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.465-474
    • /
    • 2014
  • To validate the accuracy of the boiling heat flux partitioning model, an experiment was performed to investigate how the wall heat flux is divided into the three heat transfer modes of evaporation, quenching, and single-phase convection during subcooled nucleate boiling on a vertical wall. For the experimental partitioning of the wall heat flux, the wall heat flux and liquid-vapor distributions were simultaneously obtained using synchronized infrared thermometry and the total reflection technique. Boiling experiments of water with subcooling of $10^{\circ}C$ were conducted under atmospheric pressure, and the results obtained at the wall superheat of $12^{\circ}C$ and average heat flux of $283kW/m^2$were analyzed. There was a large difference in the heat flux partitioning results between the experiment and correlation, and the bubble departure diameter and bubble influence factor, which account for a portion of the surrounding superheated liquid layer detached by the departure of a bubble, were found to be important fundamental boiling parameters.