• Title/Summary/Keyword: Bubble attenuation

Search Result 17, Processing Time 0.032 seconds

A Study on the Ship Wake Model under the Ocean Environment (해상 환경을 고려한 수상함 항적 모델 연구)

  • Bae, Ho Seuk;Kim, Won-Ki;Son, Su-Uk;Kim, Woo-Shik;Park, Joung-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.22-30
    • /
    • 2021
  • The ship wake generated by rotation of the propeller yields changes of characteristics of sound wave such as attenuation and scattering. To develope a battle field environment simulator for military purposes, it is very important to understand acoustical properties of ship wake. Existing research results have limitations in direct application because they performed under simple conditions or model ships were applied. In this study, we developed a ship wake generation model based on the ship's geometric wake distribution theory. The model can provide spatial distribution and void fraction with various marine environments as well as ship size. Through the developed model, geometric distribution features of ship wake according to the ship's maneuvering conditions were successfully simulated. In addition, changes of the bubble void fraction with time at any location within the battle field environment were identified. Therefore, the developed model is expected to be used in the development of a simulator to measure the acoustic characteristics of the ship wake.

A Study on Method for Improving Reproducibility in the Ultrasonic Measurement of Bone Mineral Density (초음파 골밀도 측정에서 재현성 향상 방법에 관한 연구)

  • Shin, Jeong-Sik;Ahn, Jung-Hwan;Kim, Hwa-Young;Kim, Hyung-Jun;Han, Seung-Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.10 s.241
    • /
    • pp.1430-1437
    • /
    • 2005
  • It is very important to achieve a high reproducibility in the ultrasonic measurement of bone mineral density. In this study, we examined number of sampling waveform, control of temperature, diameter of region of interest as factors to improve reproducibility. We decided the optimal number of waveforms to be converted to frequency domain as period of 1. We have minimized the effects of variable temperature and constrained generation of micro bubble by keeping temperature within a range of $32\pm0.5^{\circ}C$ with a precise temperature controlling algorithm. We also found the optimal diameter of region of interest to be 13mm. In this paper, we demonstrated the improved reproducibility by controlling various factors affecting the ultrasonic measurement of bone mineral density.

CT Findings of Bronchogenic Cyst (기관지 낭종의 전산화단층촬영 소견)

  • Cho, Hyun-Cheol;Lee, Yong-Woo;Hwang, Mi-Soo;Cho, Kil-Ho;Byun, Woo-Mok;Cho, Jae-Ho;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.226-236
    • /
    • 1995
  • We studied to evaluate CT characteristics of bronchogenic cysts. We retrospectively evaluated CT of 11 patients with pathologically proved bronchogenic cyst. Precontrast and postcontrast CT scan was performed in all. We analyzed CT with viewpoints of location, size, attenuation on pre- and postcontrast scan, and calcification. Three of 11 bronchogenic cysts were intrapulmonary in location and eight were located in the mediastinum. Two of 3 intrapulmonary bronchogenic cysts were located in the right lower lobe, and the remaining one was left lower lobe. Intrapulmonary bronchogenic cysts ranged from 6cm to 12cm in diameter (average, 9.7 cm). On CT, intrapulmonary bronchogenic cysts appeared as thin-wall air cyst, homogenous water attenuation and soft tissue attenuation with air bubble respectively. Mediastinal bronchogenic cysts were located in posterior mediastinum(n=5), superior mediastinum(n=2), middle mediastinum(n=1) respectively. These cysts ranged in size from 3cm to 8cm in diameter (average, 5.0 cm). On CT, five showed homogenous water attenuation, two soft tissue attenuation similar to that of muscle, one air-fluid level. Calcification or contrast enhancement was not detected in any cases. On operative findings, all of intrapulmonary bronchogenic cysts contained dirty pus-like material and all of mediastinal bronchogenic cysts contained whitish or yellowish mucus material. Bronchogenic cysts showed homogenous water density in many cases, homogenous soft tissue density, air-fluid level and air-filled cyst. The constellation of CT findings may be helpful in the diagnosis and differentiation of bronchogenic cyst.

  • PDF

The Correlation between Radiologic Findings and Clinicopathological Prognostic Factors in Small Peripheral Adenocarcinoma of Lung (말초 폐 발생 소형 선암에서 화상적 소견과 병리적, 임상적 예후와의 관계)

  • Park, Jae-Kil;Cho, Kyu-Do;Park, Kuhn;Moon, Seok-Whan;Rha, Suk-Joo;Choi, Si-Young;Jung, Jung-Im
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.423-431
    • /
    • 2004
  • Background : Tumor size in lung cancer is not as good a prognostic factor for adenocarcinoma as it is for other types of lung cancer; therefore it is difficult to estimate the prognosis preoperative. However, there have recently been some reports on the radiologic findings correlating to the clinicopathologic prognostic factors in peripheral small adenocarcinoma of lung. We tried to evaluate the prognostic importance of High-Resolution CT (HRCT) findings of such adenoearcinoma, Material and Method: One houndred and seventy-six surgically resected small peripheral adenocarcinoma measuring 3 cm or less in greatest dimension were reviewed radiologically and clinicopathologically. Result: The patients with greater extent of ground-glass attenuation (GGA) had better clinico-pathological factors. The tumors with gross appearance of GGA or bubble-like shape showed better clinicopathological prognostic factors than scar-like or solid shape. Conclusion: HRCT findings of small peripheral adenocarcinomas of the lung correlated well with the histologic and clinical prognostic factors. We can predict the post-operative prognosis with the radiologic findings.

Distribution of Seagrass (Zostera marina) Beds and High Frequency Backscattering Characteristics by Photosynthesis (잘피 서식지의 분포와 광합성에 의한 고주파 후방산란 특성)

  • Yoon Kwan-Seob;La Hyoung Sul;Na Jungyul;Lee Jae-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.8
    • /
    • pp.562-569
    • /
    • 2004
  • An experiment for observation of the distribution of the seagrass (zostera marina) beds and characteristics of high-frequency backscattering by the photosynthesis was conducted off the coast. Acoustic data were taken as a function of the grazing angles and the relative azimuth angles on the seagrass beds of which bottom type was sandy-mud. The transmitted source signal was a 120 kHz CW waveform. Mapping of the seagrass beds distribution was drawn up using the seagrass backscattering strength with azimuth and grazing angles. The result of the comparison backscattering strength distribution of the seagrass beds was shown to be the similar to the photograph of real seagrass beds. The seagrass backscattering strength was also compared between day and night to verify the effects of the acoustical scattering by the bubbles of Photosynthetic oxygen formed on the seagrass. In these results. it is clear that observation of the seagrass beds between day and night showed the different characteristics because the bubbles of Photosynthetic oxygen affect the acoustical scattering.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.