• 제목/요약/키워드: Bubble Particles

검색결과 81건 처리시간 0.027초

DAF 공정에서 부상속도 향상을 위한 플럭형성 조건 평가 (Evaluation of Floc Formation Conditions for Increasing Flotation Velocity in DAF Process)

  • 권순범;민진희;박노석;안효원
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.245-255
    • /
    • 2006
  • Dissolved air flotation is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In order to enhance the flotation velocity and removal efficiency of flocs in the flotation process, we tried to obtain pretreatment conditions for the optimum DAF process operation by comparing and evaluating features of actual floc formation and flotation velocity etc, according to coagulant types and conditions for flocculation mixing intensity by using PIA, PDA, and FSA. Accordingly, generating big flocs that have low density at low flocculation mixing intensity may reduce treatment efficiency. In addition, generating small flocs at high flocculation mixing intensity makes floc-bubbles smaller, which reduces flotation velocity, In this study, it was found that high flocculation mixing intensity could not remove the remaining micro-particles after flocculation, which had negative effects on treated water quality, Therefore, in order to enhance treatment efficiency in a flotation process, flocculation mixing intensity around $50sec^{-1}$ is effective.

통합형 오일 정제 시스템의 개발 (Development of an Integrated Oil Purification System)

  • 홍성호;이경희;정남화
    • Tribology and Lubricants
    • /
    • 제38권4호
    • /
    • pp.121-127
    • /
    • 2022
  • This study presents the development of an integrated oil purification system consisting of moisture removal, oil flushing, and oil filtering devices. In this system, the oil flushing device is combined with a micro-bubble generator. Oil purification is necessary for ensuring the high performance of the lubricant through the efficient removal of contaminants and thus enables good maintenance of mechanical systems. The developed purification system removes moisture, varnish, and solid particles. Moreover, during oil purification, the oil flushing device separates foreign materials and contaminants remaining in the lubricating oil piping or mechanical systems. The microbubble generator, which is combined with the oil flushing device, can separate harmful contaminants, such as sludge, wear particles, and rust, from piping or lubrication systems through the cavitation effect. Moisture is removed using a double high-vacuum chamber, while sludge and varnish are removed via electro-absorption using a high-voltage generator. Additionally, the total maintenance cost of the system is reduced through the use of domestically fabricated cartridge filters composed of glass fiber and cellulose. The heater, which maintains the temperature of the lubricant at 60℃, can process 41,000 L of lubricant simultaneously. Multiple tests confirmed that the proposed integrated purification system exhibits good performance in oil flushing and removal of water and varnish.

유류오염토양 처리를 위한 마이크로나노버블 토양세척에 관한 연구 (A Study on the Treatment of Oil Contaminated Soils with Micro-nano Bubbles Soil Washing System)

  • 최호은;정진희;한영립;김대용;정병길;최영익
    • 한국환경과학회지
    • /
    • 제20권10호
    • /
    • pp.1329-1336
    • /
    • 2011
  • The objectives of this study are to examine the processing of oils contamination soil by means of using a micronano-bubble soil washing system, to investigate the various factors such as washing periods, the amount of micro-nano bubbles generated depending on the quantity of acid injection and quantity of air injection, to examine the features involved in the elimination of total petroleum hydrocarbons (TPHs) contained in the soil, and thus to evaluate the possibility of practical application on the field for the economic feasibility. The oils contaminated soil used in this study was collected from the 0~15 cm surface layer of an automobile junkyard located in U City. The collected soil was air-dried for 24 hours, and then the large particles and other substances contained in the soil were eliminated and filtered through sieve No.10 (2 mm) to secure consistency in the samples. The TPH concentration of the contaminated soil was found to be 4,914~5,998 mg/kg. The micronano-bubble soil washing system consists of the reactor, the flow equalization tank, the micronano- bubble generator, the pump and the strainer, and was manufactured with stainless material for withstanding acidic phase. When the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 30 minutes were respectively identified as 4,931 mg/kg (18.9%), 4,678 mg/kg (18.9%) and, 4,513 mg/kg (17.7%). And when the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 120 minutes were respectively identified as4,256 mg/kg (22.3%), 4,621 mg/kg (19.7%) and 4,268 mg/kg (25.9%).

LCD 제조공정에서 물리적 세정법의 미립자 제거효율 비교 연구 (Comparison of particle removal efficiency between the physical cleaning methods in the fabrication of liquid crystal displays)

  • 박창범;이승준;장인성
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.795-801
    • /
    • 2010
  • LCD (Liquid Crystal Display) 제조기술이 발전함에 따라 유리기판은 점차 대형화되는 추세이고 제조공정도 세밀화되어 감에 따라 LCD 제조과정에서 세정공정의 중요성이 부각되고 있다. 본 연구에서는 물리적 세정방법 중 브러쉬 (brush), 버블제트 (bubble jet) 및 이류체 (aqua/air) 세정법을 이용하여 미립자 (particles) 제거효율을 비교 평가하였다. 7세대 LCD 유리기판 ($1875\;mm\;{\times}\;2200\;mm$)을 대상으로 초순수 (deionized water)의 유량 및 압력 변화와 브러쉬의 모(毛)와 유리기판과의 접촉깊이 (contact depth) 등의 운전조건 변화를 통하여 미립자의 제거효율을 비교하였고 각 세정법에 의한 유의차 분석을 통해 향후 세정장비 개발에 유용한 자료로 활용하고자 하였다. 브러쉬 세정의 경우 브러쉬 접촉깊이에 변화를 주었을 때 임계점부터는 세정효율에 유의차가 크지 않음을 알 수 있었다. 버블제트 세정은 압력변화에 따른 세정력 유의차가 거의 없음을 관찰할 수 있었으며, 이류체 세정은 압력변화시 임계점까지는 세정력 유의차가 존재하나 임계점 이후부터는 유의차가 발생하지 않았다. 상기 3가지 세정방법 중 브러쉬 세정이 주어진 조건에서는 세정효과가 가장 큰 것으로 나타났다.

Efficient Opaque Ice Sphere Formation Using a Lightweight Geometric Approach

  • Jong-Hyun Kim
    • 한국컴퓨터정보학회논문지
    • /
    • 제29권3호
    • /
    • pp.91-98
    • /
    • 2024
  • 본 논문에서는 공기방울이 있는 불투명한 얼음 구를 효율적으로 표현할 수 있는 기하학적 접근법 기반의 입자-격자 혼합 프레임워크를 소개한다. 격자를 통해 수온이 확산되고 입자를 통해 얼음 내부에 표현되는 공기방울을 표현한다. 노이즈한 용존공기장(Dissolved air field)이 생성되는 이전 기법의 문제를 해결하기 위해 본 논문에서는 레벨셋을 이용하여 알고리즘을 경량화한다. 즉, 활성화 입자(Active particle)의 개수와 초기 용존산소량(Dissolved oxygen)을 이용하여 열확산의 종료 조건을 효율적으로 제어한다. 또한 공기방울 근처에만 계산했던 이전 용존공기장 기법을 투명한 영역에도 확산하여 사실적인 얼음 구를 표현했고, 입자의 방향성을 정확하게 계산하기 위해 레벨셋 기반의 접근법을 소개한다. 결과적으로 본 논문에서 제시한 방법은 기존 기법에 비해 약 3배정도 빨랐으며 시각적으로 개선된 불투명 얼음 구의 가시화 결과를 보여주기 때문에 물리적인 가상 얼음 형태를 표현하는 분야에 활용될 수 있다.

수중의 마그네슘과 알루미늄 이온이 기포의 제타전위에 미치는 영향 (The Effect of Magnesium and Aluminium Ions on Zeta Potential of Bubbles)

  • 한무영;안현주;신민석
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.573-579
    • /
    • 2004
  • Electroflotation, which is used as an alternative to sedimentation, is a separation treatment process that uses small bubbles to remove low-density particulates. Making allowances for recent collision efficiency diagram based on trajectory analysis, it is necessary to tailor zeta potential of bubbles that collide with negatively charged particles. In this paper, the study was performed to investigate the effects of magnesium and aluminium ions on zeta potential of bubbles. And, it was studied to find out factors which could affect the positively charged bubbles. Consequently, zeta potential of bubbles increased both with higher concentration of metal ions and in the acidic pH value. And, a probable principle that explained the procedure of charge reversal could be a combined mechanism with both specific adsorption of hydroxylated species and laying down of hydroxide precipitate. It also depended on the metal ion concentration in the solution to display its capacity to control the bubble surface.

바이오매스 급속열분해 반응기내 열전달 특성 (HEAT TRANSFER CHARACTERISTICS IN A FAST PYROLYSIS REACTOR FOR BIOMASS)

  • 최항석
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.9-16
    • /
    • 2010
  • The characteristics of flow and heat transfer in a bubbling fluidized bed are investigated by means of computational fluid dynamics (CFD). To simulate two-phase flow for the gas and solid flows, Eulerian-Eulerian approach is applied. Attention is paid for a heat transfer from the wall to fluidized bed by bubbling motion of the flow. From the result, it is confirmed that heat transfer is promoted by chaotic bubbling motion of the flow by enhancement of mixing among solid particles. In particular, the vortical flow motion around gas bubble plays an important role for the mixing and consequent heat transfer. Discussion is made for the time and space averaged Nusselt number which shows peculiar characteristics corresponding to different flow regimes.

등방성 난류에서의 마이크로버블 거동 (BEHAVIOR OF MICROBUBBLES IN ISOTROPIC TURBULENCE)

  • 심기훈;이슬기;이창훈
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.46-53
    • /
    • 2016
  • Direct numerical simulation is conducted to observe the behavior of microbubbles in isotropic turbulence. Navier-Stokes equation and the motion of equation for microbubbles are solved with periodic boundary condition in a cube domain. Vorticity contour, enstrophy ratio, relative reduction of bubble rise velocity, and the closest distance of particles are investigated for various Stokes numbers and gravity factors to understand clustering of microbubbles. Also, clustering due to the effect of the lift force is investigated.

BNR 하수처리시스템에서 효과적 고형물 분리를 위한 DAF 공정의 적용과 처리특성 (Treatment Characteristics and Application of DAF Process for Effective Solid Separation in BNR Municipal Wastewater Treatment System)

  • 곽동희;유대환
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.267-276
    • /
    • 2010
  • Many plants have been improved to adapt the target of the biological treatment processes changed from organics to nutrients since the water quality criteria of effluent was reinforced and included T-N and T-P for the municipal wastewater treatment plant. To meet the criteria of T-N and T-P, the conventional biological reactor such as aeration tank in activated sludge system is changed to the BNR (biological nutrient removal) processes, which are typically divided into three units as anaerobic, anoxic and oxic tank. Therefore, the solid separation process should be redesigned to fit the BNR processes in case of the application of the DAF (dissolved air flotation) process as an alternatives because the solid-liquid separation characteristics of microbial flocs produced in the BNR processes are also different from that of activated sludge system as well. The results of this study revealed that the microbial floc of the anaerobic tank was the hardest to be separated among the three steps of the unit tanks for the BNR processes. On the contrary, the oxic tank was best for the removal efficiency of nutrients as well as suspended solid. In addition, the removal efficiency of nutrients was much improved under the chemical coagulation treatment though coagulation was not indispensable with a respect to the solid separation. On the other hand, in spited that the separation time for the microbial floc from the BNR processes were similar to the typical particles like clay flocs, over $2.32{\times}10^3$ ppm of air volume concentration was required to keep back the break-up of the bubble-floc agglomerates.

이종 강화재를 첨가한 폴리우레탄 폼의 기계적 및 열적 특성과 제작 시 초음파 분산의 영향 (Mechanical and Thermal Characteristics of Polyurethane Foam with Two Different Reinforcements and the Effects of Ultrasonic Dispersion in Manufacturing)

  • 김진연;김정대;이제명
    • 대한조선학회논문집
    • /
    • 제56권6호
    • /
    • pp.515-522
    • /
    • 2019
  • Since Liquefied Natural Gas (LNG) is normally carried at 1.1 bar pressure and at -163℃, special Cargo Containment System (CCS) are used. As LNG carrier is becoming larger, typical LNG insulation systems adopt a method to increase the thickness of insulation panel to reduce sloshing load and Boil-off Rate (BOR). However, this will decrease LNG cargo volume and increase insulation material costs. In this paper, silica aerogel, glass bubble were synthesized in polyurethane foam to increase volumetric efficiency by improving mechanical and thermal performance of insulation. In order to increase dispersibility of particles, ultrasonic dispersion was used. Dynamic impact test, quasi-static compression test at room temperature (20℃) and cryogenic temperature (-163℃) was evaluated. To evaluate the thermal performance, the thermal conductivity at room temperature (20℃) was measured. As a result, specimens without ultrasonic dispersion have a little effect on strength under the compressive load, although they show high mechanical performance under the impact load. In contrast, specimens with ultrasonic dispersion have significantly increased impact strength and compressive strength. Recently, as the density of Polyurethane foam (PUF) has been increasing, these results can be a method for improving the mechanical and thermal performance of insulation panel.