• Title/Summary/Keyword: Brightness temperature

Search Result 450, Processing Time 0.026 seconds

The Combined Environmental Factors on the Human Physiological and Psychological Responses in Indoor Space (실내공간의 복합 환경 조건이 인체의 생리 및 심리반응에 미치는 영향)

  • Yoon, In
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.3
    • /
    • pp.87-94
    • /
    • 2012
  • Kruithof demonstrated the preferred combination of illuminance levels and color temperatures. However, as Benett pointed out, difference of themal variables in such preference may be expected. The purpose of this study is to clarify the combined effects of lighting conditions(illuminance, color temperature), operative temperature on the human physiological and psychological responses. In order to observe operative temperature change in preference of color temperatures for three illumination levels, three subjects were exposed to two different conditions of color temperatures of 2,850K, 4,200K and 6,850K combined with operative temperatures(OT) of $25{\sim}31^{\circ}C$ at 100~1000lx. Thermal sensation vote and comfortable sensation vote, brightness perception vote were reported in each experiment conditions. The following results were obtained : 1) When illuminace level was at 100lx in operative temperatures of OT $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$, Color temperature affect not themal sensation but Warm-cool sensation. 2) Operative temperatures affect not brightness perception vote but visual comfort sensation vote, satisfactive sensation vote, warm-cool sensation vote and themal sensation vote.

Modeling and Optimizing Brightness Development in Peroxide Bleaching of Thermomechanical Pulp

  • Wang, Li-Jun;Park, Kyoung-Hwa;Yoon, Byung-Ho
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.5
    • /
    • pp.86-94
    • /
    • 1999
  • Alkaline peroxide bleaching of chemi-mechanical pulp is a very complicated system where various process factors affect the bleacing performance and pulp properties. Traditional onefactor-at a time method is ineffective and costly infinding the optimal bleaching conditions. In this study, statistical experimental design and multiple regression method wre used to investigated the interactions among various bleaching factors and to find out the possbile maximal brightness development during one stage alkaline peroxide bleacing of TMP. The TMP was made from 10% Korean red pine and 90% Korean spruce and had an initial brightness of 54.5% ISO. the TMP was pretreated with EDTA(0.5% on O.D. pulp, 3% pulp consistency, 30$^{\circ}C$ for 60 minutes) and bleached in a 2 L Mark V Quantum Reactor at 750 rmp, 7.5% of bleaching consistency and with 0.05% magnesium sulfate addition. The ranges of chemical factors studied , based on oven-ried pulp, were 1-5% for hydrogen peroxide, 1-4% for sodium hydroxide and 1-4% for sodium silicate. The rages of reaction temperature and time were 50-90$^{\circ}C$ and 40-180minutes respectively. Interactions of hydrogen peroxide with alkali , time with temperature ature, alkali with time and silicate with temperature were found to be significant which means that hydrogen peroxide bleaching will be favored at stable concentration of perhydroxyl ion, relatively short time and low temperature, and high level of silicate. Mathematical model which has good predictability for target brightness in one stage peroxide bleaching can also be established easily. Base ion the model, maximal brightness of 70% ISO was found to at 50$^{\circ}C$ and 50 minutes by chemical additions of 5% for hydrogen peroxide, 3.2-3.4% for sodium hydroxide and 4% for silicate based on O.D. pulp. However, this result might not be suitable for situation where furnishes are different from ours, or different pretreatment is used, or bleaching carried out at different pulp consistency. In these cases it will be good to re-investigate the process by a similar methodology as was used in this study.

  • PDF

The Detection of Yellow Sand Dust Using the Infrared Hybrid Algorithm

  • Kim, Jae-Hwan;Ha, Jong-Sung;Lee, Hyun-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.370-373
    • /
    • 2005
  • We have developed Hybrid algorithm for yellow sand detection. Hybrid algorithm is composed of three methods using infrared bands. The first method used the differential absorption in brightness temperature difference between $11\mu m\;and\;12\mu m$ (BID _1), through which help distinguish the yellow sand from various meteorological clouds. The second method uses the brightness temperature difference between $3.7\mu m\;and\;11\mu m$ (BID_2). The technique would be most sensitive to dust loading during the day when the BID _2 is enhanced by reflection of $3.7\mu m$ solar radiation. The third one is a newly developed algorithm from our research, the so-called surface temperature variation method (STY). We have applied the three methods to MODIS for derivation of the yellow sand dust and in conjunction with the Principle Component Analysis (PCA), a form of eigenvector statistical analysis. PCI shows better results for yellow sand detection in comparison with the results from individual method. The comparison between PCI and MODIS aerosols optical depth (AOD) shows remarkable good correlations during daytime and relatively good correlations over the land.

  • PDF

Soil Moisture Content Estimation Using Remote Sensing Technique (원격 측정 기법을 이용한 토양 함수비의 측정)

  • Lee, Jae Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.535-542
    • /
    • 1994
  • Remote sensing technique is based on the estimation of land surface characteristics from the measurement of the emitted radiation from the earth. The hydrologically related parameters studied using this approach include surface temperature, evapotranspiration, soil moisture, precipitation and snow. This study introduces a method for estimating moisture content of a bare soil from the observed and simulated brightness temperature. In a bare soil, microwave emission depends on moisture content, soil temperature, and surface roughness. The method is based on a radiative transfer model with some modifications of Fresnel reflection coefficient to take into account the effect of surface roughness. One smooth bare field and two fields with different surface roughness are prepared for the study. The results indicate that the effect of surface roughness is to increase the soil's brightness temperature and to reduce the slope of regression between brightness temperature and moisture contents.

  • PDF

Variation of Oak Kraft Pulp Properties by Xylanase Treatment in C/D, P and Z Stage (C/D, P 및 Z단계 표백시 Xylanase처리에 의한 펄프성질의 변화)

  • Kim, Dong-Ho;Paik, Ki-Hyon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 1997
  • The objectives of this study was to decrease pollutions of bleaching effluent and was to enhanced brightness of non-chlorine bleached pulps by xylanase treatments. Xylanase cloned Esherichacoli(E. coli) capable of each of endo, exo-xylanase and acetyl-esterase were obtained from Bacillus stearothermophillus. These xylanase was maintained high activity in alkali and high temperature. Especially endo-xylanase would be more active in $60^{\circ}C$ and pH 11. Xylanase pretreatment(X) of unbleached pulp increased brightness, and decreased the degree of delignification. The degree of increase in brightness of pulp due to xylanase pretreatment was similar to non-enzyme treated pulp, regardless of the amount of enzyme added. Therefore, the addition of xylanase of 2 unit was recommended when considering costs of enzyme. The pulp bleached XO sequence had higher brightness and lower Kappa no, than O bleached pulp, while pulp bleached XP sequence had similar brightness and Kappa no. with P bleached pulp. In XOC/D, XOZ and XOP bleaching sequences, brightness and degree of delignification were improved. The C/D and Z stage bleached pulp was good effect on rate of raise in brightness and Kappa no., but P stage bleached pulp had similar level in non-enzyme treated bleaching sequence.

  • PDF

THE ASSOCIATION OF NEUTRAL HYDROGEN WITH HII REGIONS AND RADIO SOURCES

  • Minn, Young-Key
    • Journal of The Korean Astronomical Society
    • /
    • v.18 no.2
    • /
    • pp.100-110
    • /
    • 1985
  • The HI features associated with HII regions and radio sources in the galactic-plane are searched in the Maryland-Green Bank Galactic 21-cm Line Survey. Among the twenty-eight such objects, twenty-five show HI depression features, two no feature, and an emission feature with excess HI brightness temperature. Most of these feature are surrounded by strong HI emissions. The depth of the HI depression is proportional to the radio continuum brightness temperature. The angular dimensions of the HI feature and radio source are comparable. The small HI depressions shown at the positions of HII region located in the outer solar circle are considered to be HI self-absorption features of very cold HI gas.

  • PDF

Effect of Tannin Mordanting on Gromwell-dyed Silk Fabric (견직물의 자초 염색 시 합성탄닌의 매염 효과)

  • Park, Ah-Young;Song, Wha-Soon;Kim, In-Young
    • Textile Coloration and Finishing
    • /
    • v.20 no.6
    • /
    • pp.51-62
    • /
    • 2008
  • The purpose of this study was to check color change depending on dyeing conditions when silk fabrics was dyed with gromwell and to investigate mordant effect when synthetic tannin was used as a mordant. First, when silk fabrics were dyed with gromwell, the change of color, brightness and chroma were examined by measuring K/S value, a, b value, L value and C value depending on dyeing condition. Second, color, brightness and chroma differences which appeared after mordanting with synthetic tannin were investigated and muti-functional mordanting effect was confirmed with dyeing fastness, antibiosis. As a result of color analysis of gromwell, it was proved that the main pigment of gromwell was shikonin. Color was red purple at pH 3 when silk fabrics were dyed with gromwell. But It became greenish and bluish as temperature rose and time passed by. And it grew reddish and yellowish as concentration level reached higher. The color became purple at pH 5 and purple blue at pH 7. Both at pH 5 and pH 7, it became greenish and yellowish, as temperature went up and time ran by. And it became reddish with concentration increasing. Brightness and chroma decreased with temperature and concentration increasing as well as time passing by. After mordanting with synthetic tannin, the color became less reddish at pH 3 and reddish-yellowish at pH 5 and pH 7. The brightness increased and the chroma decreased. At all pH, the color, the brightness and the chroma became similarly by synthetic tannin mordanting. Dyeing fastness of synthetic tannin mordanted fabric was higher than that of non-mordanted fabric. Especially, wet fastness at pH 3 improved from 1 grade before synthetic tannin mordanting to $3{\sim}4$ grade after tannin mordanting. Antibiosis was improved by gromwell dyeing and synthetic tannin mordanting.

Inverse Brightness Temperature Estimation for Microwave Scanning Radiometer

  • Park, Hyuk;Katkovnik, Vladimir;Kang, Gum-Sil;Kim, Sung-Hyun;Choi, Jun-Ho;Choi, Se-Hwan;Jiang, Jing-Shan;Kim, Yong-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.1
    • /
    • pp.53-59
    • /
    • 2003
  • The passive microwave remote sensing has progressed considerably in recent years Important earth surface parameters are detected and monitored by airborne and space born radiometers. However the spatial resolution of real aperture measurements is constrained by the antenna aperture size available on orbiting platforms and on the ground. The inverse problem technique is researched in order to improve the spatial resolution of microwave scanning radiometer. We solve a two-dimensional (surface) temperature-imaging problem with a major intention to develop high-resolution methods. In this paper, the scenario for estimation of both radiometer point spread function (PSF) and target configuration is explained. The PSF of the radiometer is assumed to be unknown and estimated from the observations. The configuration and brightness temperature of targets are also estimated. To do this, we deal with the parametric modeling of observation scenario. The performance of developed algorithms is illustrated on two-dimensional experimental data obtained by the water vapor radiometer.

Use of uniform distribution for generating synthetic brightness temperature in passive microwave soil moisture retrieval

  • Lee Khil-Ha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.19-28
    • /
    • 2005
  • Passive microwave remote sensing technique have shown great potential for mon monitoring regional/global surface soil moisture. Given a single measurement at dual polarization/single frequency/single view angle, a strategic approach to artificially generating multiple microwave brightness temperatures is presented. And then the statistically generated microwave brightness temperature data are applied to the inverse algorithm, which mainly relies on a physically based microwave emission model and an advanced single-criterion multi-parameter optimization technique, to simultaneously retrieve soil moisture and vegetation characteristics. . The procedure is tested with dual polarized Tropical Rainfall Measurement Mission Microwave Imager (TRMM/TMI) over two different cover sites in Oklahoma and Beltsville field experimental data. The retrieval results are analyzed and show excellent performance.

  • PDF

Optic Characteristics Comparison and Analysis of SMD Type Y/G/W HB LED (SMD형 Y/G/W HB LED의 광특성 비교분식)

  • 황명근;허창수;서유진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2004
  • The optical characteristics; luminous flux, correlated color temperature, and CIE -chromaticity coordinate etc., of HB LED(high brightness light emitting diode) of yellow/green/white SMD(surface mounted device) type were tested with integrating sphere photometer and monochromator, and the results were comparatively evaluated And, for the white LED, color rendering indices were considered to analyze.