• Title/Summary/Keyword: Bridge Displacement

Search Result 776, Processing Time 0.027 seconds

Development of Structure Dynamic Characteristics Analysis System Prototype using Image Processing Technique (영상처리기법을 이용한 구조물 동특성 분석 시스템 프로토타입 개발)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Jung-Hoon;Kim, Do-Keun;Yoon, Kwang-Won
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.11-21
    • /
    • 2016
  • Recently, structure safety management techniques using cutting-edge technology(Displacement senor, sensor of acceleration) has emerged as an important issue owing to the aging of infrastructure such as bridge and building. In general, the structural monitoring system for structure safety management is based on IT technology and it is expensive to install. In this paper developed an image-based structure dynamic characteristic analysis system prototype to assess the damage of structure in a more cost-effective way than traditional structure health monitoring system. The inspector can take a video of buildings or other structures with digital camera or any other devices that is passible to take video, and then using NCC calculation for image processing technique to get natural frequency. This system is analysis of damage of the structure using a compare between the frequency response ratio and functions when problems are occurs send alarm to administrator. This system is easier to install and remove than previous monitoring sensor in economical way.

Stability Analysis for CWR on the Railway Bridges by Linearized Method (선형해석법을 이용한 교량상 장대레일의 안정성 해석 방법 연구)

  • Choi, Young-Gil;Oh, Ju-Won
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.4
    • /
    • pp.472-480
    • /
    • 2009
  • The stability analysis for CWR is difficult in the theory itself because both geometric and material nonlinearity should be considered. Also the analysis results are varied according to the loading history. In contrast to the complexity in the theory, the analysis results for CWR on the railway bridges are quite simple and can be predicted because of a small buckling effect and its negligible nonlinearity. In this study, refined nonlinear analysis methods for the stability analysis of CWR on the railway bridges were developed which consider only material nonlinearity beeause the effects of geometric nonlinearity are nominal. In this study, the analysis results can be found within limited number of iterations with idealized linear force-displacement relationship. From the analysis result comparisons, it was found that the stability analysis for CWR on the railway bridges can be performed effectively by this method.

Variational Formulation for Shape Optimization of Spatial Beam Structures (정식화를 이용한 3차원 구조물의 형상 최적설계)

  • 최주호;김종수
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.123-130
    • /
    • 2002
  • A general formulation for shape design sensitivity analysis over three dimensional beam structure is developed based on a variational formulation of the beam in linear elasticity. Sensitivity formula is derived based on variational equations in cartesian coordinates using the material derivative concept and adjoint variable method for the displacement and Von-Mises stress functionals. Shape variation is considered for the beam shape in general 3-dimensional direction as well as for the orientation angle of the beam cross section. In the sensitivity expression, the end points evaluation at each beam segment is added to the integral formula, which are summed over the entire structure. The sensitivity formula can be evaluated with generality and ease even by employing piecewise linear design velocity field despite the bending model is fourth order differential equation. For the numerical implementation, commercial software ANSYS is used as analysis tool for the primal and adjoint analysis. Once the design variable set is defined using ANSYS language, shape and orientation variation vector at each node is generated by making finite difference to the shape with respect to each design parameter, and is used for the computation of sensitivity formula. Several numerical examples are taken to show the advantage of the method, in which the accuracy of the sensitivity is evaluated. The results are found excellent even by employing a simple linear function for the design velocity evaluation. Shape optimization is carried out for the geometric design of an archgrid and tilted bridge, which is to minimize maximum stress over the structure while maintaining constant weight. In conclusion, the proposed formulation is a useful and easy tool in finding optimum shape in a variety of the spatial frame structures.

  • PDF

Impact Factor Analysis of Response Adjustment Factor of PSC Composite Bridge Using Optical Fiber Sensor (광섬유 센서를 이용한 PSC 합성형교의 응답보정계수 영향인자 분석)

  • Kim, Ho Sun;Jang, Hwa Sup;Yang, Dong Woon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • In general, load carrying capacity, one of the load & resistance capacities in bridges, has more margins than the load carrying capacity evaluated with theoretical methods, unless there are severe damages, defects or material deterioration phenomena that can have a great impact on the behavior of bridges. However, errors have been already included in the current processes of loading tests and structural analysis for measuring load carrying capacity, thus devaluing the reliability of response adjustment factor. Therefore, this study found out the problems of existing electric resistance strain and displacement sensors in sensor suite to solve the problems with sensors and the errors in the appropriateness of structural analysis model, thereby leading to the changes into an optical fiber smart sensor with excellent performance. Besides, the study attempted to ensure the accuracy of response adjustment factor by selecting the optimal models through the interpretation of various structural analysis models.

Effects of number and angle of T Shape non persistent cracks on the failure behavior of samples under UCS test

  • Sarfarazi, V.;Asgari, K.;Maroof, S.;Fattahi, Sh
    • Computers and Concrete
    • /
    • v.29 no.1
    • /
    • pp.31-45
    • /
    • 2022
  • Experimental and numerical simulation were used to investigate the effects of angle and number of T shape non-persistent crack on the shear behaviour of crack's bridge area under uniaxial compressive test. concrete samples with dimension of 150 mm×150 mm×40 mm were prepared. Within the specimen, T shape non-persistent notches were provided. 16 different configuration systems were prepared for T shape non-persistent crack based on two and three cracks. In these configurations, the length of cracks were taken as 4 cm and 2 cm based on the cracks configuration systems. The angle of larger crack related to horizontal axis was 0°, 30°, 60° and 90°. Similar to cracks configuration systems in the experimental tests, 28 models with different T shape non-persistent crack angle were prepared in numerical model. The length of cracks were taken as 4 cm and 2 cm based on the cracks configuration systems. The angle of larger crack related to horizontal axis was 0°, 15°, 30°, 45°, 60°, 75° and 90°. Tensile strength of concrete was 1 MPa. The axial load was applied to the model. Displacement loading rate was controlled to 0.005 mm/s. Results indicated that the failure process was significantly controled by the T shape non-persistent crack angle and crack number. The compressive strengths of the specimens were related to the fracture pattern and failure mechanism of the discontinuities. Furthermore, it was shown that the compressive behaviour of discontinuities is related to the number of the induced tensile cracks which are increased by increasing the crack number and crack angle. The strength of samples decreased by increasing the crack number. In addition, the failure pattern and failure strength are similar in both methods i.e. the experimental testing and the numerical simulation methods (PFC2D).

Experimental Study on the Flexural Behavior of Inverted T-Shaped Steel·Concrete Composite Deck for Bridges (역T형강·콘크리트 합성바닥판의 휨거동에 관한 실험적 연구)

  • Kim, Sung Hoon;Park, Young Hoon;Lee, Seung Yong;Choi, Jun Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.331-340
    • /
    • 2008
  • This study is to suggest the details of new concept of bridge deck. Experimental studies on the behavior of a inverted T-shaped steelconcrete composite deck were carried out. The part of inverted T-shaped steel is embedded in concrete. Reinforced concrete deck specimen and composite deck specimens were fabricated and static bending fracture tests were conducted. The ultimate strength and fracture strength of specimens were evaluated. The effects of shear hole crossing bars of composite deck were also analyzed. From the results of experiments, composite deck with shear hole crossing bar increased shear strength, and showed typical tensile failure. Ultimate strength and fracture strength of composite deck with shear hole crossing bar are higher than those of reinforced concrete deck. The displacement of composite deck is higher than that of reinforced concrete deck.

Vibration and Noise Level on the Training Ship Pusan 403 (실습선 부산 403호의 진동과 소음)

  • Park, Jung Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.8-8
    • /
    • 1987
  • This paper describes on the distribution of the vibration and the noise produced on a skipjack pole and line training ship M/S Pusan 403 (243GT, 1,000ps) under the cruising or drifting condition. The vibration and the noise level were measured by use of protable vibration analyzer (B and K 3513) and sound level meter (B and K 2205), and so the vibration level was converted into dB unit. The check points were set through every decks and around important places of the ship. The results obtained can be summarized as follows: 1. The vibration and the noise level 1) On the main deck, both the vibration and the noise level were highest at the vertically above the main engine, whereas the vibration level was the lowest in the bow store and the noise level beneath the bridge. 2) Under cruising condition, the vibration level around the cylinder head of main engine, port side of the engine room, on the shaft tunnel was 80, 67, 65 dB and the noise level 104, 87, 86 dB, respectively. 3) The vibration level on the vertical line passing through the bridge was the highest at the orlop deck with 60 dB and the lowest on the bridge deck with 55 dB, whereas the noise level the highest at the compass deck with 75 dB and the lowest at the orlop deck with 53 dB. 4) The vibration and the noise level on the open decks were the highest with 65 dB and 84 dB on the boat deck, whereas the vibration level was the lowest at the lecture room with 51 dB and the noise level the lowest at the fore castle deck with 57 dB. 5) On the orlop decks, both the vibration and the noise level were the highest at the engine room with 65 dB and 85 dB, and the lowest at bow store with 54 dB and 52 dB, respectively. Comparing with the vibration level and the noise level, the vibration level was higher than the noise level in the bow part and it was contrary in the stern part of the ship. 2. Vibration analysis 1) The vibration displacement and the vibration velocity were the greatest at the cylinder head of main engine with 100μm and 11mm/sec, and were the smallest at the compass deck with 3μm and 0.07mm/sec. They were also attenuated rapidly around the frequency of 100Hz and over. 2) The vibration acceleration was the greatest at the cylinder head with the main frequency of 1KHz and the acceleration of 1.1mm/sec super(2), and the smallest at the compass deck with 30KHz and 0.05mm/sec super(2).

Vibration and Noise Level on the Training Ship Pusan 403 (실습선 부산 403호의 진동과 소음)

  • 박중희
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.54-60
    • /
    • 1987
  • This paper describes on the distribution of the vibration and the noise produced on a skipjack pole and line training ship M/S Pusan 403 (243GT, 1,000ps) under the cruising or drifting condition. The vibration and the noise level were measured by use of protable vibration analyzer (B and K 3513) and sound level meter (B and K 2205), and so the vibration level was converted into dB unit. The check points were set through every decks and around important places of the ship. The results obtained can be summarized as follows: 1. The vibration and the noise level 1) On the main deck, both the vibration and the noise level were highest at the vertically above the main engine, whereas the vibration level was the lowest in the bow store and the noise level beneath the bridge. 2) Under cruising condition, the vibration level around the cylinder head of main engine, port side of the engine room, on the shaft tunnel was 80, 67, 65 dB and the noise level 104, 87, 86 dB, respectively. 3) The vibration level on the vertical line passing through the bridge was the highest at the orlop deck with 60 dB and the lowest on the bridge deck with 55 dB, whereas the noise level the highest at the compass deck with 75 dB and the lowest at the orlop deck with 53 dB. 4) The vibration and the noise level on the open decks were the highest with 65 dB and 84 dB on the boat deck, whereas the vibration level was the lowest at the lecture room with 51 dB and the noise level the lowest at the fore castle deck with 57 dB. 5) On the orlop decks, both the vibration and the noise level were the highest at the engine room with 65 dB and 85 dB, and the lowest at bow store with 54 dB and 52 dB, respectively. Comparing with the vibration level and the noise level, the vibration level was higher than the noise level in the bow part and it was contrary in the stern part of the ship. 2. Vibration analysis 1) The vibration displacement and the vibration velocity were the greatest at the cylinder head of main engine with 100$\mu$m and 11mm/sec, and were the smallest at the compass deck with 3$\mu$m and 0.07mm/sec. They were also attenuated rapidly around the frequency of 100Hz and over. 2) The vibration acceleration was the greatest at the cylinder head with the main frequency of 1KHz and the acceleration of 1.1mm/sec super(2), and the smallest at the compass deck with 30KHz and 0.05mm/sec super(2).

  • PDF

A Study on Moment Gradient Factor for Inelastic Lateral-Torsional Buckling Strength of Stepped I-Beam Subjected to Linear Moment Gradient (선형 모멘트 하중을 받는 계단식 단면변화 I형보의 비탄성 횡-비틀림 좌굴강도산정을 위한 모멘트 구배계수 연구)

  • Park, Jong-Sup;Son, Ji-Min
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.53-60
    • /
    • 2008
  • The cross-sections of continuous multi-span beams sometimes suddenly increase, or become stepped, at the interior supports of continuous beams to resist high negative moments. The three-dimensional finite-element program ABAQUS (2007) was used to analytically investigate the inelastic lateral-torsional buckling behavior of stepped beams subjected to linear moment gradient and resulted in the development of design equations. The ratios of the flange thickness, flange width, and stepped length of beam are considered for the analytical parameters. Two groups of 27 cases and 36 cases, respectively, were analyzed for doubly and singly stepped beams in the inelastic buckling range. The combined effects of residual stresses and geometrical imperfection on inelastic lateral-torsional buckling of beams are considered. First, the distributions of residual stress of the cross-section is same as shown in Pi and Trahair (1995), and the initial geometric imperfection of the beam is set by central displacement equal to 0.1% of the unbraced length of beam. The new proposed equations definitely improve current design methods for the inelastic lateral-torsional buckling problem and increase efficiency in building and bridge design.

Improvement and Seismic Performance Evaluation of RC Exterior Beam-Column Joints Using Recycled Coarse Aggregate with Hybrid Fiber (순환굵은골재 치환과 하이브리드섬유 혼입에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능 평가 및 개선)

  • Ha, Jae-Hoon;Ha, Gee-Joo;Shin, Jong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.160-169
    • /
    • 2015
  • In this study, experimental research was carried out to improve the seismic performance of reinforced concrete exterior beam-column joint regions using replacing recycled coarse aggregate with hybrid fiber (steel fiber+PVA fiber) in existing reinforced concrete building. Therefore it was constructed and tested seven specimens retrofitting the beam-column joint regions using such retrofitting materials. Specimens, designed by retrofitting the beam-column joint regions of reinforced concrete building, were showed the stable failure mode and increase of load-carrying capacity due to the effect of crack control at the times of initial loading and bridge of retrofitting hybrid fiber during testing. Specimens BCJGPSR series, designed by the retrofitting of replacing recycled coarse aggregate with hybrid fiber in reinforecd beam-column joint regions were increased its maximum load carrying capacity by 1.01~1.04 times and its energy dissipation capacity by 1.06~1.29 times in comparison with standard specimen BCJS. Also, specimen $BCJGPSR_1$ were increased its energy dissipation capacity by 1.33~1.65 times in comparison with specimens BCJS, BCJP and BCJGPR series for a displacement ductility of 9.