• Title/Summary/Keyword: Breast size change

Search Result 51, Processing Time 0.023 seconds

A Preliminary Study on Method for Evaluation and Diagnosis of Late Luteal Phase Dysphoric Disorder in Women - Focusing on Psychiatric Outpatients - (후기 황체기 불쾌기분 장애의 평가 방법 및 진단에 관한 예비 연구 - 정신과 외래환자를 대상으로 -)

  • Yi, Sang-Kyu;Joe, Sook-Haeng;Kwak, Dong-Il
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.3 no.2
    • /
    • pp.115-125
    • /
    • 1995
  • Reports about the prevalence of premenstrual symptoms state that occurs in 20 to 100% of most reproductive-age women. There is a close association between premenstrual syndrome and affective disorders as well as same some other psychiatric disorders. Late luteal phase dysphoric disorder (LLPDD) is a premenstrual condition defined in DSM-III-R by severe mood changes and other symptoms that repeatedly occur only in the luteal phase of the menstrual cycle. However, DSM-III-R does not specify how to compute the change from the follicular to the luteal phase or how to determine when the amount of change is great enough to warrant the diagnosis nor how to determine occupational or social functional impairment. This study was conducted to evaluate the nature, severity and magnitude of premenstrual syndrome in women with current psychiatric disorders by using prospective Daily Rating Form(DRF), and to measure symptom changes according to three scoring methods for diagnosing LLPDD. Our study obtains the data about premenstrual changes estimated by DRF from 22 women with psychiatric disorders who had met criteria for major depressive syndrome on the Premenstrual Assessment Form (PAF). The data was scored by each three methods and was determined to meet criteria A for LLPDD. The results are as follows: 1) the subjects, when scored according to the percent change method, effect size method and absolute severity method, met the DSM-III-R criteria A for LLPDD in 36.4% (8 subjects), 14% (3 subjects) and 4.5% (1 subject) of the cases respectively. 2) The items of irritability, anger and impatience were occurred most frequently on the DRF, when it was scored according to the three scoring methods. And the item of breast pain was next frequent according to the effect size method and the percent change method but according to the absolute severity method. 3) The PAF item of impaired social functioning was reported by 16 (73%) of the subjects. 4) 4 (18%) of the subjects met criteria A for LLPDD and reported impaired social functioning. The prevalency of LLPDD according to each method varied. The percent change method yielded the greatest (36.4%), and the absolute seventy method yielded the laest (4.5%), The effect size method yielded an intermediate frequency (14%). Therefore, for maximizing the diagnostic accuracy of LLPDD, a diagnostic procedure including a measure of change (e.q., effect size method, percent change method) as well as confirmed diagnosis by DRF, will be needed. Also, an accurate tool to evaluate impaired social functioning will be required.

  • PDF

A Change of fashin IIIustration by the Ideal Type of Human Body Beauty (인체미의 이상형에 따른 패션 일러스트레이션의 변화)

  • 전경숙
    • Journal of the Korean Society of Costume
    • /
    • v.28
    • /
    • pp.65-84
    • /
    • 1996
  • The purpose of this study is to analyze the relation between the beauty of human body and the fashion illustration in each period And I attained my object through the investigation of features and changes of illustration which is given a vivid description of the features and development of ideal humam body beauty. By various methods I studied this subject. Frist I refered to sundry records Secondly I investiated the fashion illustrations which are included in Vogue. On the basis of this data I grasped the ideal types of human body beauty which is founded during the social change in each 10 years. And I analyzed the relation be-tween the ideal type and fashion illustration which show the change of fashion. The summary of result is as follows. 1. In the early part of the 20th century the beauty of human body is represented with the figure of large-sized beauty which emphasize shoulder and bust. And fashion ikllustration show 9 life-size broad shoulder full bust lim waist and hourglass silhouette. 2, In the 1910s the swell of strength vanishes gradually and shoulder and sleeve are straight type. And fashion illustration show 7 life-size high waist line. And that is tublar sil-houette of high waist and streamline shape in which bust and hip are not emphasized. 3. In the 1920s the ideal type of human body beauty is straight type which shows flat bust and unexaggerate hip. And fashion illus-tration is about 8 life-size tublar silhouette of low waist and lunger and slimmer and young style in which bust and hip are not emph-asized. 4. In the 1930s the ideal is womamly slim and long style. Fashion illustration is about 8 life-size and slim & long silhouette in which waist line is emphasized and bust and hip line come out. 5. In the 1940s the ideal type is womamly style which has narrow shoulder rich bast and slim waist. And fashion illustration is about 7 life-size and hourglass silhouette which has unartificial shoulder slim waist and empha-sized bust. 6. In the 1950s the ideal type is that of ro-bust health which emphasize build and muscu-lar system. And fashion illustration is 8.5 life-size and show full bust and made waist slimmer. That is sheath silhouette. 7. In the child who has full face with large eyeball slender and long leg: narrow and immatured body comparatively big head. And fashion illus-tration is 7 life-size and show slim and long neck flat bust long and slim limbs and big head. That is H type silhouette. 8. In the 1970s the ideal type is high stat-ure flat breast small hip and wide shoulders. And fashion illustration is wide shoulders and slim waist as 11 life-size and straight sil-houete. 9. In the 1980s the ideal type is extremely emphasized breadth of shoulder because healthy body and muscle are recognized as the symbol of ideal attractiveness. And fashion il-lustration is about 8.5 life-size and show mus-cular slim type that is slim silhouette. 10 At the present time the ideal type is slim and tall type which is empasized healthy beauty. And fashion illustration is 12 life-size which has healthy body and skin So that is slim and long type.

  • PDF

A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography (유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구)

  • Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.751-759
    • /
    • 2023
  • Breast ultrasonography is difficult to image in fatty breasts and to find micro-calcification, but the discovery of micro-calcification is very important for breast cancer screening. Among the color Doppler artifact of ultrasound, twinkle artifact mainly occur on strong reflectors such as stones or calcification in images, and evaluation methods using them are clinically being used. In this study, we are conducting experiments on the color Doppler settings of ultrasound equipment, such as repetition frequency, ensemble, persist, wall filtering, smoothing, linear density, and dissociation value, by producing a breast simulation phantom using the largest amount of calcium phosphate among breast implants. The purpose of this study was to improve the contrast of twinkle artifact in breast ultrasound examinations and to maximize their use in clinical practice. As a result, the pulse repetition frequency occurred in the range of 3.6 kHz to 7.2 kHz, and did not occur above 10.5 kHz. For ensembles, twinkle artifact occurred in all sizes of calcification under low conditions, and in threshold settings, the twinkle artifact increased slightly only under 80 to 100 conditions, and did not occur in 1 mm size calcification. Persist, wall filter, smoothing, and line density settings did not have much meaning in the setting variable because conditions did not increase by condition, and pulse repetition frequency, ensemble, and thresholds had the greatest impact on the twinkling artifact image. This study is expected to help examiners select optimal conditions to effectively increase twinkle artifact by adjusting color Doppler settings.

A Study on the Change of Body Composition of Female Adolescents for School Uniform Design (교복 설계를 위한 여자 청소년의 체형 변화 연구)

  • Kim, Seowoo;Nam, Yun Ja;Kim, Kyoung Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.2
    • /
    • pp.224-236
    • /
    • 2020
  • In this study, the 4th (1997) and 6th (2013) direct measurements of Size Korea compared the changing shape of women between the ages of 12 and 18. Comparing the items of height and length, the height and shoulder height were significantly reduced, the waist height was not significantly different, and the height of the upper hip was significantly increased, resulting in a smaller upper torso ratio and a higher lower torso rate. The width and thickness associated with human obesity, the circumference items and obesity levels often increased significantly with the change of the times, indicating that the overall body size was increased and that the chest area was changed to a cylindrical shape with changes in the breast equilibrium. Comparing agespecific measurements with graphs analyzing the trend of change in growth, the results showed that the change in 1997 was minimal since age 14; however, a continuous increase was achieved in 2013 that corresponded to the age at which growth is complete. The results of these studies are expected to be used as basic data to predict pattern design, body implementation, and trends in shape changes for young women.

A study of the round Variation Design Brassiere Pattern

  • Park, You-Shin;Choi, Yeong-Soon
    • Journal of Fashion Business
    • /
    • v.12 no.6
    • /
    • pp.81-92
    • /
    • 2008
  • The purpose of this study is to develop the applied brassiere pattern of women which are fitting for 75A. The constructing of this experimental brassiere were lower cup, upper cup, front panel and U-wing as well as a full cup embcing the entire breasts. Basing on the bra model from domestic experiment results, development of an applied design, round side type pattern, has been suggested. Thus, suggesting the round variation design bra, which is an applied design based on the basic model based on the breast volume. Based on the sizes that are in reference to Size Korea (2004) and related previous researches, the basic model that has been experimented with 11.4% polyurethane and 88.6% Nylon as the materials, has been selected as the model of research. This takes 75A, the size of which is set according to the underbust circumference and the breasts circumference, as the basic model. It is an application in terms of design, and there is no change to the cup volume or size because it has been moved only from the cutting line. The applied design changes the right side of the lower cup into an easily-movable form and attaches it to the upper cup, and the lower cup takes the right part of the upper cup to form a cup shape of round variation design. It also changes basic straight form of the wings, and alters them into U-shape.

Radiologic Findings of Uncommon Breast Cancer (드문(Uncommon) 유방암의 방사선학적 소견)

  • Kim, Jae-Woon;An, Jae-Hong;Hwang, Mi-Soo;Lee, Jae-Kyo;Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.114-124
    • /
    • 1998
  • We analyzed the mammographic (n=21) findings (location, margin, shape, cluster microcalcifications, size, multiplicity) and ultrasonographic (n=12) findings (shape, border, internal echo, boundary echo, posterior echo, lateral echo, width/depth ratio) to evaluate specific radiologic findings of histopathologically proved uncommon breast cancer. The mammographic findings (n=21) are as follow; 1) single; 16, multiple; 5 2) margin (smooth; 13, irregular; 4, spiculated; 4) 3) shape (round and ovoid; 9, lobulated; 8, irregular; 4) 4) cluster micro calcifications (abscent; 20, present; 1) 5) size (1-3cm; 18, 3-5cm; 2, 5cm> ; 1) 6) location (UOQ; 13, UIQ; 4, LIQ; 3, LOQ; 1). The ultrasonographic findings (n=12) are as follow; 1) shape (round to oval; 5, lobulated; 5, irregular; 2) 2) border (smooth even; 9, rough uneven; 3) 3) internal echo (fine homogeneous; 5, coarse heterogeneous; 7) 4) boundary echo (regular fine; 4, irregular thick; 8) 5) posterior echo (enhanced; 11, no change; 1) 6) lateral echo (marked; 7, nonexistent; 5) 7) width/depth ratio (1.5> ; 1, 1.0-1.5; 7, 1.0< ; 4). Uncommon breast cancer show benign nature on mammogram, but malignant nature on ultrasonogram (especially boundary echo, internal echo, width/depth ratio).

  • PDF

Volumetric change of the latissimus dorsi muscle after postoperative radiotherapy in immediate breast reconstruction with an extended latissimus dorsi musculocutaneous flap

  • Park, Tae Seo;Seo, Jung Yeol;Razzokov, Anvar S.;Choi, June Seok;Kim, Min Wook;Lee, Jae Woo;Kim, Hyun Yeol;Jung, Youn Joo;Choo, Ki Seok;Song, Kyeong Ho;Nam, Su Bong
    • Archives of Plastic Surgery
    • /
    • v.47 no.2
    • /
    • pp.135-139
    • /
    • 2020
  • Background This study aimed to determine the magnitude of volume reduction of the latissimus dorsi (LD) muscle after treatment using only postoperative radiotherapy (PORTx) in patients who underwent immediate breast reconstruction using an extended LD musculocutaneous (eLDMC) flap after partial mastectomy. Methods We retrospectively reviewed 28 patients who underwent partial mastectomy and an eLDMC flap, received only PORTx, and underwent chest computed tomography (CT) 7 to 10 days after surgery and 18±4 months after the end of radiotherapy, from March 2011 to June 2016. The motor nerve to the LD was resected in all patients. One plastic surgeon performed the procedures, and the follow-up period was at least 36 months (mean, 46.6 months). The author obtained LD measurements from axial CT views, and the measurements were verified by an experienced radiologist. The threshold for statistical significance was set at P<0.05. Results A statistically significant decrease in the LD volume was found after the end of PORTx (range, 61.19%-80.82%; mean, 69.04%) in comparison to the measurements obtained 7 to 10 days postoperatively (P<0.05). All cases were observed clinically for over 3 years. Conclusions The size of an eLDMC flap should be determined considering an average LD reduction of 69% after PORTx. Particular care should be taken in determining the size of an eLDMC flap if the LD is thick or if it occupies a large portion of the flap.

The Effect of Spiral Balance Taping on Postoperative Sequelae in Breast Cancer : Case study (스파이랄 발란스 테이핑이 유방암 환자의 수술 후 후유증에 미치는 영향 : 사례연구)

  • Su-Ji Kang;Dae-Hee Lee;Cheul Jang;Back-Vin Lim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose : Cancer survivors often suffer from postoperative sequelae. the diagnosing and provision of manual therapy using spiral taping significantly improves the quality of life of cancer patients. The aim of this case study is to investigate the immediate effects of spiral taping on pain, range of motion (ROM), chemotherapy-induced peripheral neuropathy (CIPN), and lymphedema following breast cancer surgery. Methods : The taping techniques were performed as follows by spiral taping. The measurements were taken before, in the middle, and after taping using a mobile phone camera, tape measure, and a numerical rating score (NRS). The evaluation employed a single-group pre-post design based on a primitive experimental design. Results : Out of four patients, all four exhibited Reverse circle flow energy (RCFE), Passive cervical right (Rt) rotation test, anterior-posterior movement pattern, nerve type (+), cold energy (CE), sangcho acupuncture point, blood clot, hwal point. Comparing before and after treatment, almost all values were reduced to zero after treatment in terms of pain complaints. The lack of range of motion (ROM) caused by the shortened tissue after surgery did not increase. The range of motion (ROM) lost due to pain returned to normal. The circumference of lymphedema did not show a tendency. The symptoms of CIPN improved. Conclusion : There was a significant change in joint range of motion, with pain decreasing, but there were structural limitations in the tissue due to total resection, and the chemotherapy-induced peripheral neuropathy scale. It was effectively treated surgical site pain, axillary membrane syndrome-induced pain, and unexplained pain. While there was a treatment effect for lymphedema in the evaluation of circumference values, there was no significant change in circumference. There was a significant effect on chemotherapy-induced peripheral neuropathy, particularly in treating numbness in the feet, which is a side effect of TC anticancer drugs. This case study found that spiral balance taping provides a rapid therapeutic effect for most side effects in patients who have undergone total breast cancer resection. However, the generalization is limited due to the small sample size, and further research is needed to determine the extent to which the effects of one treatment are maintained.

Levels of Depression and Anxiety Post-Mastectomy in Breast Cancer Patients at a Public Sector Hospital in Karachi

  • Khan, Sara;Khan, Naveed Ali;Rehman, Ata Ur;Khan, Iqra;Samo, Khursheed A;Memon, Amjad Siraj
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1337-1340
    • /
    • 2016
  • Background: There is a noticeable change in the approach with which women nowadays seek help for diseases like breast cancer, primarily due to awareness campaigns, but what happens after surgical procedures is of great significance too. This study focused on the several psychological connotations attached to mastectomy and how the patients cope. Objective: To understand the pattern of anxiety and level of depression among Pakistani patients undergoing mastectomy. Materials and Methods: The sample size consisted of 88 patients who had undergone mastectomy at the different surgical units of the Civil Hospital, Karachi, from January 2012-December 2014; The questionnaire was administered before they were discharged i.e. within 3 days of surgical procedures. The patients were asked if they were willing to participate in this study, those who agreed signed the consent form and then we preceded by asking questions with a standardized tool. A self made questionnaire was constructed keeping in mind the nature and specification of the disease, which consisted of 20 questions related to anxiety and depression, focusing on a mixture of psychological and physiological symptoms. Results: There were a total of 88 patients out of which 36 (41%) were aged 51 to 60 years, 24 (27.2%) of the patients were in the age category of 41 to 50 years, 17 aged 61 and above (19.3%) and only 11 (12.5%) 30-40 years of age, the youngest of all the age categories. The pattern of depression and anxiety was found to be similar among all age categories, severe depression and anxiety predominating over moderate level of such symptoms, with only relatively few patients sufering mild or no depression symptoms. Conclusions: It was concluded that going through mastectomy leads to moderate to severe levels of depression and anxiety, primarily because the females feel incomplete and insecure after losing a part of themselves.

Evaluation of Image Quality according to Insert Position and Thickness Change by Fabricating Modified ACR Phantom in Mammography (유방엑스선검사에서의 변형된 ACR 팬텀 제작을 통한 모조병소의 위치와 두께 변화에 따른 영상의 품질 평가)

  • Uhm, Hyon-Ja;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.103-109
    • /
    • 2022
  • To maintain improved image quality in mammography, the quality control process is performed using the ACR (American college of radiology) phantom. In addition, many studied were performed by fabricating the customized breast phantom to provide more information in mammography. Thus, the purpose of this study was to evaluate the image quality by designing the modified ACR phantoms. The five modified acrlylic ACR phantoms were designed by considering insert position and phantom thickness. The phantoms were consisted of 4.5, 3.0, and 1.5 cm in terms of phantom thickness, and 3.0, 2.0, and 0.5 cm in terms of insert position, respectively. The acquired images were evaluated by PSNR (peak signal to noise ratio), RMSE (root mean square error), CC (correlation coefficient), CNR (contrast to noise ratio), and COV (coefficient of variation). Based on the similarity analysis, the result is suitable between conventional and new designed phantoms. In addition, the CNR and COV results in terms of insert position showed that image quality for 0.5 cm was 2.3 and 27.4% improved compared with 2 and 3 cm, respectively. According to phantom thickness results, the CNR result for 1.5 cm and COV result for 4.5 cm were 50.1 and 62.7% improved compared with that those conditions. In conclusion, we confirmed that the image quality depends on the breast size and thickness through modified ACR phantom study.