• Title/Summary/Keyword: Breast imaging

Search Result 417, Processing Time 0.027 seconds

Clinical Outcome in Gamma Knife Radiosurgery for Metastatic Brain Tumors from the Primary Breast Cancer : Prognostic Factors in Local Treatment Failure and Survival

  • Choi, Seung Won;Kwon, Do Hoon;Kim, Chang Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.4
    • /
    • pp.329-335
    • /
    • 2013
  • Objective : Brain metastases in primary breast cancer patients are considerable sources of morbidity and mortality. Gamma knife radiosurgery (GKRS) has gained popularity as an up-front therapy in treating such metastases over traditional radiation therapy due to better neurocognitive function preservation. The aim of this study was to clarify the prognostic factors for local tumor control and survival in radiosurgery for brain metastases from primary breast cancer. Methods : From March 2001 to May 2011, 124 women with metastatic brain lesions originating from a primary breast cancer underwent GKRS at a tertiary medical center in Seoul, Korea. All patients had radiosurgery as a primary treatment or salvage therapy. We retrospectively reviewed their clinical outcomes and radiological responses. The end point of this study was the date of patient's death or the last follow-up examination. Results : In total, 106 patients (268 lesions) were available for follow-up imaging. The median follow-up time was 7.5 months. The mean treated tumor volume at the time of GKRS was 6273 $mm^3$ (range, 4.5-27745 mm3) and the median dose delivered to the tumor margin was 22 Gy (range, 20-25 Gy). Local recurrence was assessed in 86 patients (216 lesions) and found to have occurred in 36 patients (83 lesions, 38.6%) with a median time of 6 months (range, 4-16 months). A treated tumor volume >5000 $mm^3$ was significantly correlated with poor local tumor control through a multivariate analysis (hazard risk=7.091, p=0.01). Overall survival was 79.9%, 48.3%, and 15.3% at 6, 12, and 24 months, respectively. The median overall survival was 11 months after GKRS (range, 6 days-113 months). Multivariate analysis showed that the pre-GKRS Karnofsky performance status, leptomeningeal seeding prior to initial GKRS, and multiple metastatic lesions were significant prognostic factors for reduced overall survival (hazard risk=1.94, p=0.001, hazard risk=7.13, p<0.001, and hazard risk=1.46, p=0.046, respectively). Conclusion : GKRS has shown to be an effective and safe treatment modality for treating brain metastases of primary breast cancer. Most metastatic brain lesions initially respond to GKRS, though, many patients have further CNS progression in subsequent periods. Patients with poor Karnofsky performance status and multiple metastatic lesions are at risk of CNS progression and poor survival, and a more frequent and strict surveillance protocol is suggested in such high-risk groups.

Dosimetric Effects of Intrafractional Organ Motion in Field-in-Field Technique for Whole-Breast Irradiation

  • Hong, Chae-Seon;Ju, Sang Gyu;Choi, Doo Ho;Han, Youngyih;Huh, Seung Jae;Park, Won;Ahn, Yong Chan;Kim, Jin Sung;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.30 no.3
    • /
    • pp.65-73
    • /
    • 2019
  • Purpose: We evaluated the motion-induced dosimetric effects on the field-in-field (FIF) technique for whole-breast irradiation (WBI) using actual patient organ motion data obtained from cine electronic portal imaging device (cine EPID) images during treatment. Materials and Methods: Ten breast cancer patients who received WBI after breast-conserving surgery were selected. The static FIF (SFIF) plan involved the application of two parallel opposing tangential and boost FIFs. To obtain the amplitude of the internal organ motion during treatment, cine EPID images were acquired five times for each patient. The outside contour of the breast (OCB) and chest wall (CW) contour were tracked using in-house motion analysis software. Intrafractional organ motion was analyzed. The dynamic FIF (DFIF) reflecting intrafractional organ motion incorporated into the SFIF plan was calculated and compared with the SFIF in terms of the dose homogeneity index (DHI90/10) for the target and V20 for the ipsilateral lung. Results: The average motion amplitudes along the X and Y directions were 1.84±1.09 mm and 0.69±0.50 mm for OCB and 1.88±1.07 mm and 1.66±1.49 mm for CW, respectively. The maximum motion amplitudes along the X and Y directions were 5.53 and 2.08 mm for OCB and 5.22 and 6.79 mm for CW, respectively. Significant differences in DHI90/10 values were observed between SFIF and DFIF (0.94 vs 0.95, P<0.05) in statistical analysis. The average V20 for the lung in the DFIF was slightly higher than that of the SFIF in statistical analysis (19.21 vs 19.00, P<0.05). Conclusion: Our findings indicate that the FIF technique can form a safe and effective treatment method for WBI. Regular monitoring using cine EPID images can be effective in reducing motion-induced dosimetric errors.

A Case Report of Intraductal Carcinoma Detected in a Patient Undergoing Surveillance for Benign Breast Mass (유방 양성 종괴 추적 관찰 환자에게서 발견된 관상피내암 증례 보고)

  • Il-Bong Moon;Jong-Gil Kwak;Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.743-749
    • /
    • 2023
  • Breast ductal carcinoma in situ(DCIS) refers to cases in which breast epithelial cells have become malignant but are still limited to normal ducts, and has been increasing rapidly in recent years. In this case, a two-year follow-up revealed findings on mammography and ultrasonography that indicated a small mass classified as BI-RADS Category 3, However far from typical malignant tumor these findings were. In the second year of follow-up, a hypoechoic mass with an indistinct boundary of the right breast in the 6 o'clock direction, on mammography appeared to be about 2.1×1.3 cm in size, and biopsy diagnosed it as ductal carcinoma. Since ductal endothelial cancer has no characteristic clinical findings and can show positive clinical and imaging findings in the early stages, regular follow-up is considered important for early diagnosis, and detection of ductal endothelial cancer through mammography and ultrasound is important for improving the prognosis of all breast cancer patients. During the initial examination conducted four years ago, we reported cases of intra ductal cancer in which asymmetric shading, microcalcification, and branched mass, indicative of intra ductal cancer, were observed during follow-up. It is advisable to concurrently explore methods for reducing X-ray dosage to mitigate potential side effects of contrast medium.

Application of Point Shearwave Elastography to Breast Ultrasonography: Initial Experience Using "S-Shearwave" in Differential Diagnosis (Point Shearwave Elastography의 유방 초음파에서의 적용: "S-Shearwave"를 이용한 감별진단의 초기경험)

  • Myung Hwan Lee;Eun-Kyung Kim;Eun Ju Lee;Ha Yan Kim;Jung Hyun Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.157-165
    • /
    • 2020
  • Purpose To evaluate the optimal measurement location, cut-off value, and diagnostic performance of S-Shearwave in differential diagnosis of breast masses seen on ultrasonography (US). Materials and Methods During the study period, 225 breast masses in 197 women were included. S-Shearwave measurements were made by applying a square region-of-interest automatically generated by the US machine. Shearwave elasticity was measured three times at four different locations of the mass, and the highest shearwave elasticity was used for calculating the optimal cut-off value. Diagnostic performance was evaluated by using the area under the receiving operator characteristic curve (AUC). Results Of the 225 breast masses, 156 (69.3%) were benign and 69 (30.7%) were malignant. Mean S-Shearwave values were significantly higher for malignant masses (108.0 ± 70.0 kPa vs. 43.4 ± 38.3 kPa; p < 0.001). No significant differences were seen among AUC values at different measurement locations. With a cut-off value of 41.9 kPa, S-Shearwave showed 85.7% sensitivity, 63.9% specificity, 70.7% accuracy, and positive and negative predictive values of 51.7% and 90.8%, respectively. The AUCs for US and S-Shearwave did not show significant differences (p = 0.179). Conclusion S-Shearwave shows comparable diagnostic performance to that of grayscale US that can be applied for differential diagnosis of breast masses seen on US.

Impact of Skeletal Muscle Loss and Visceral Obesity Measured Using Serial CT on the Prognosis of Operable Breast Cancers in Asian Patients

  • Mi-ri Kwon;Eun Sook Ko;Min Su Park;Woo Kyoung Jeong;Na Young Hwang;Jae-Hun Kim;Jeong Eon Lee;Seok Won Kim;Jong Han Yu;Boo-Kyung Han;Eun Young Ko;Ji Soo Choi;Ko Woon Park
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.159-171
    • /
    • 2022
  • Objective: This study aimed to investigate the impact of baseline values and temporal changes in body composition parameters, including skeletal muscle index (SMI) and visceral adipose tissue area (VAT), measured using serial computed tomography (CT) imaging on the prognosis of operable breast cancers in Asian patients. Materials and Methods: This study retrospectively included 627 Asian female (mean age ± standard deviation [SD], 53.6 ± 8.3 years) who underwent surgery for stage I-III breast cancer between January 2011 and September 2012. Body composition parameters, including SMI and VAT, were semi-automatically calculated on baseline abdominal CT at the time of diagnosis and follow-up CT for post-treatment surveillance. Serial changes in SMI and VAT were calculated as the delta values. Multivariable Cox regression analysis was used to evaluate the association of baseline and delta SMI and VAT values with disease-free survival. Results: Among 627 patients, 56 patients (9.2%) had breast cancer recurrence after a median of 40.5 months. The mean value ± SD of the baseline SMI and baseline VAT were 43.7 ± 5.8 cm2/m2 and 72.0 ± 46.0 cm2, respectively. The mean value of the delta SMI was -0.9 cm2/m2 and the delta VAT was 0.5 cm2. The baseline SMI and VAT were not significantly associated with disease-free survival (adjusted hazard ratio [HR], 0.983; 95% confidence interval [CI], 0.937-1.031; p = 0.475 and adjusted HR, 1.001; 95% CI, 0.995-1.006; p = 0.751, respectively). The delta SMI and VAT were also not significantly associated with disease-free survival (adjusted HR, 0.894; 95% CI, 0.766-1.043; p = 0.155 and adjusted HR, 1.001; 95% CI, 0.989-1.014; p = 0.848, respectively). Conclusion: Our study revealed that baseline and early temporal changes in SMI and VAT were not independent prognostic factors regarding disease-free survival in Asian patients undergoing surgery for breast cancer.

Reliability study of the Pectoralis Minor Muscle Thickness Measurement using Rehabilitative Ultrasound Imaging

  • Lim, Ji Young;Lee, Se-Yeong;Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2021
  • PURPOSE: This study examined the imaging procedure of pectoralis minor muscle thickness and assessed the intra- and inter-rater reliability of the muscle thickness measured by two raters using rehabilitative ultrasound imaging (RUSI) in healthy individuals. METHODS: Fifteen participants (aged 21 - 28, seven females, and eight males) were involved in the study. The primary rater palpated the coracoid process and the fourth rib, defined as the width of the index finger lateral to the sternum to avoid breast tissues, and lined the two landmarks. The second examiner checked 1 / 3 (1st point) and 1 / 2 (2nd point) of the line length as measurement points. The two raters obtained right side muscle images of the participants at a standardized sitting position using RUSI with a 7.5 MHz linear transducer at 40mm depth. For intra-rater reliability, the principal rater took three images per point and tried to take one more with an interval. For the inter-rater reliability, the other rater performed the same tasks as the principal rater on the same day. The reliability was analyzed using the intra-class correlation coefficient (ICC), the standard error of the measurement (SEM), and Bland and Altman plots. RESULTS: The reliability at all points was excellent for the same rater (ICC3,1 = .973 - .978, SEM = .042 - .046), and between raters (ICC2,1 = .939 - .959, SEM = .059 - .097). CONCLUSION: These findings show that the RUSI could be reliable for examining the pectoralis minor muscle thickness in healthy individuals at all measurement sites.

Clinical Significance of Focal Breast Lesions Incidentally Identified by $^{18}F-FDG$ PET/CT ($^{18}F-FDG$ PET/CT에서 우연히 발견된 국소 유방 병변의 임상적 의의)

  • Cho, Young-Seok;Choi, Joon-Young;Lee, Su-Jin;Hyun, Seung-Hyup;Lee, Ji-Young;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.456-463
    • /
    • 2008
  • Purpose: We evaluated the incidence and malignant risk of focal breast lesions incidentally detected by $^{18}F-FDG$ PET/CT. Various PET/CT findings of the breast lesions were also analyzed to improve the differentiation between benign from malignant focal breast lesions. Materials & Methods: The subjects were 3,768 consecutive $^{18}F-FDG$ PET/CT exams performed in adult females without a history of breast cancer. A focal breast lesion was defined as a focal $^{18}F-FDG$ uptake or a focal nodular lesion on CT image irrespective of $^{18}F-FDG$ uptake in the breasts. The maximum SUV and CT pattern of focal breast lesions were evaluated, and were compared with final diagnosis. Results: The incidence of focal breast lesions on PET/CT in adult female subjects was 1.4% (58 lesions in 53 subjects). In finally confirmed 53 lesions of 48 subjects, 11 lesions of 8 subjects (20.8%) were proven to be malignant. When the PET/CT patterns suggesting benignancy (maximum attenuation value>75 HU or <30HU; standard deviation of mean attenuation > 20) were added as diagnostic criteria of PET/CT to differentiate benign from malignant breast lesions along with maximum SUV, the area under ROC curve of PET/CT was significantly increased compared with maximum SUV alone ($0.680{\pm}0.093$ vs. $0.786{\pm}0.076$, p<0.05). Conclusion: The malignant risk of focal breast lesions incidentally found on $^{18}F-FDG$ PET/CT is not low, deserving further diagnostic confirmation. Image interpretation considering both $^{18}F-FDG$ uptake and PET/CT pattern may be helpful to improve the differentiation from malignant and benign focal breast lesion.

The quantitative analysis of Diffusion Weighted Imaging in Breast MRI (유방 MRI 검사에서 확산강조영상의 정량적 분석)

  • Cho, Jae-Hwan;Kim, Hyeon-Ju;Hong, Yin-Sik;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.149-154
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of diffusion weighted images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, diffusion weighted images and ADC map images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The diffusion weighted images showed higher SNR and CNR at the lesion area. In addition, the ADC values were lower at the lesion area.

MOM-Based Born Iterative Method for Medical Microwave Imaging (의용 전자파 영상을 위한 MoM 기반 Born 반복법의 적용)

  • Son, Jae-Gi;Kim, Bo-Ra;Lee, Taek-Kyung;Son, Seong-Ho;Jeon, Soon-Ik;Lee, Jae-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.4
    • /
    • pp.524-532
    • /
    • 2012
  • In this paper, we used MOM-based BIM(Born Iterative Method) algorithm to implement the inverse scattering for the detection of cancer. We adopted two-dimensional breast structure, integral equations and two-dimensional Green's function is solved with MoM(Method of Moment) to analyzing electromagnetic scattering phenomena. In addition, verifying the calculation of developed inverse scattering algorithm and analyzing medical applicability and limitations of the algorithm.

Breast Cancer Detection with Thermal Images and using Deep Learning

  • Amit Sarode;Vibha Bora
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.8
    • /
    • pp.91-94
    • /
    • 2023
  • According to most experts and health workers, a living creature's body heat is little understood and crucial in the identification of disorders. Doctors in ancient medicine used wet mud or slurry clay to heal patients. When either of these progressed throughout the body, the area that dried up first was called the infected part. Today, thermal cameras that generate images with electromagnetic frequencies can be used to accomplish this. Thermography can detect swelling and clot areas that predict cancer without the need for harmful radiation and irritational touch. It has a significant benefit in medical testing because it can be utilized before any observable symptoms appear. In this work, machine learning (ML) is defined as statistical approaches that enable software systems to learn from data without having to be explicitly coded. By taking note of these heat scans of breasts and pinpointing suspected places where a doctor needs to conduct additional investigation, ML can assist in this endeavor. Thermal imaging is a more cost-effective alternative to other approaches that require specialized equipment, allowing machines to deliver a more convenient and effective approach to doctors.