• Title/Summary/Keyword: Breast dose

Search Result 540, Processing Time 0.026 seconds

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

Nanoparticles Promise New Methods to Boost Oncology Outcomes in Breast Cancer

  • Islamian, Jalil Pirayesh;Hatamian, Milad;Rashidi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1683-1686
    • /
    • 2015
  • Different types of treatment are available for patients with breast cancer, the most being radiotherapy, chemotherapy, hormonal therapy and combination therapy. Recently, nanoparticles have been emerging as promising agents for cancer therapy and are being investigated as contrast agents, drug carriers, radiosensitizers and also for hyperthermia effects. In this review the focus is on approaches for targeted treatment of breast cancer by combining nanoparticles, chemodrugs and radiation. The availble data suggest the possibility of increased roles for combined therapy, particularly by reducing the dose of each treatment modality, and consequently minimizing related side effects.

Effect of Lycopus lucidus Trucz on Cell Growth of Human Breast Cancer Cells, MCF-7

  • Kim, Do-Yeon;Ghil, Sung-Ho
    • Biomedical Science Letters
    • /
    • v.15 no.2
    • /
    • pp.147-152
    • /
    • 2009
  • Lycopus lucid us Turcz is well known as traditional Chinese medicine, and it has been shown to exhibit antiinflammatory, -allergic and -oxidative effect. However, its anti-cancer properties have not been examined yet. In this study, we investigated the effect of the methanol extract of Lycopus lucid us Turcz on anti-cancer effect in MCF-7 human breast cancer cells. Treatment of Lycopus lucidus Turcz extract induced apoptosis and inhibition of cell proliferation in dose- and time-dependent manner. Apoptosis in the MCF-7 cells was characterized with the changes in nuclear morphology; decrease of Bcl-2 and caspase-7 expression; and increase of cleaved poly ADP-ribose polymerase(PARP). Furthermore, treatment of Lycopus lucidus Turcz extract caused the down-regulation of cell cycle-related protein including, cdk4, cyclin D1 and E2F-1. These results suggest that Lycopus lucidus Turcz might have the therapeutic value against human breast cancer cells.

  • PDF

Anti-tumor Activity of Dendrostellera lessertii and the Inhibitory Effect of One of Its Purified Diterpene Ester on Wehi-164 cell Adhesion

  • Yazdanparast, R.;Mianabadi, M.;Abdolmohammadi, M.H.
    • Natural Product Sciences
    • /
    • v.9 no.3
    • /
    • pp.161-166
    • /
    • 2003
  • In the course of our studies for new anticancer medicinal plants, we evaluated the effects of an alcohol-water (1:1, V/V) extract of Dendrostellera lesserii (Thymelaeaceae) leaves on the growth rates of breast tumors of rats. The breast tumors were induced in a group of rats by Dimethylbenz[a]anthracene (DMBA) injection. Our data showed that daily oral feeding of the crude extract to the rats, for 20 consecutive weeks, significantly repressed the growth rates of the breast tumors. In addition, the probable effect of D. lessertii crude extract or one of its purified active components on metastasis was evaluated using wehi-164 cells. Treatment of the cells with a single nontoxic dose of the purified active component for 48 hours inhibited the adhesion of the cells to the immobilized fibronectin molecules by almost 80% compared to the untreated control cells.

Inhibitory effect of Rhus verniciflua Stokes extract in MCF-7 human breast cancer cells (참옻 추출물의 MCF-7 인체 유방암 세포에서 증식 억제효과)

  • Kim, Min Sung;An, Won Gun;Lee, Jang Cheon
    • Herbal Formula Science
    • /
    • v.24 no.4
    • /
    • pp.283-288
    • /
    • 2016
  • Objectives : The purpose of this study was to investigate the anti-cancer effects of extract of Rhus verniciflua Stokes (RVS) in human breast cancer cell lines. Methods : In cultured human breast cancer MCF-7 cells, we investigated growth inhibitory effect of RVS. MCF-7 cells were cultured with various concentrations (0, 200, 300, and 400 ug/ml) of RVS at $37^{\circ}C$ for 24 h. We performed CCK-8 assay and flow cytometry for detection of Annexin V-PI staining. Results : As a result, RVS inhibits the cell growth and induction of apoptosis in dose dependent manner in MCF-7 breast cancer cells. Conclusion : RVS has anti-cancer activities and induced apoptosis in human breast cancer MCF-7 cells. Therefore we suggest that RVS can use as a novel class of anti-cancer drugs.

Anti-oxidant Effects of Anemarrhenae Rhizoma in Three Different Lineages (지모(知母) 추출물이 MCF-7 세포의 생존율에 미치는 영향)

  • Kim, Hyung-Woo;Kim, Bu-Yeo;Cho, Su-Jin;Cho, Su-In
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.3
    • /
    • pp.608-614
    • /
    • 2007
  • Objectives : This study was carried out to investigate anti-proliferative effects on MCF-7 human breast cancer cells of Anemarrhenae Rhizoma (AR) extract. Breast cancer is the most common disease in Korean women. Despite remarkable improvements in treatment strategies against various cancers during the past 40 years. breast cancer still remains as one of the main causes of cancer mortality among women the whole world over. Methods : Be investigated the effects of AR on cytotoxicity of MCF-7 human breast cancer cells in various extract conditions (n-hexane, ethyl acetate, butanol and water fraction). Results : The extract of Anemarrhenae Rhjzoma inhibits the proliferation of MCF-7 cells in a dose dependent manner. Especially. the ethyl acetate fraction of Anemarrhenae Rhizoma showed specific Cytotoxicity on MCF-7 cells. Conclusions : In conclusion. it can be concluded that Anemarrhenae Rhizoma extract has an anti-proliferative effect on MCF-7 human breast cancer cells. Especially. the ethyl acetate fraction is most effective to inhibit proliferation of MCF-7 cells.

  • PDF

Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use

  • Son, Jaeman;Jung, Seongmoon;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.159-164
    • /
    • 2021
  • Purpose: We investigated the properties of CLEANBOLUS based on silicone with suitable characteristics for clinical use. Methods: We evaluated the characteristics of CLEANBOLUS and compared the results with the commercial product (Super-Flex bolus). Also, we conducted physical evaluations, including shore hardness, element composition, and elongation break. Transparency was investigated through the measured absorbance within the visible region (400-700 nm). Also, dosimetric characteristics were investigated with surface dose and beam quality. Finally, the volume of unwanted air gap was investigated based on computed tomography images for breast, chin, and nose using Super-Flex bolus and CELANBOLUS. Results: CLEANBOLUS showed excellent physical properties for a low shore hardness (000-35) and elongation break (>1,000%). Additionally, it was shown that CLEANBOLUS is more transparent than Super-Flex bolus. Dosimetric results obtained through measurement and calculation have an electron density similar to water in CLEANBOLUS. Finally, CLEANBOLUS showed that the volume of unwanted air gap between the phantom and each bolus is smaller than Super-Flex bolus for breast, chin, and nose. Conclusions: The physical properties of CLEANBOLUS, including excellent adhesive strength and lower shore hardness, reduce unwanted air gaps and ensure accurate dose distribution. Therefore, it would be an alternative to other boluses, thus improving clinical use efficiency.

Low Dose Effect and Non Monotonic Dose Responses(NMDRs) and its Medical Meaning - Focusing on A New Paradigm of Dose-Response Relationship - (Low Dose Effect와 Non Monotonic Dose Responses(NMDRs) 그리고 의학적 의미 - 용량-반응관계의 새로운 패러다임을 중심으로 -)

  • Sung, Angela Dongmin;Shin, Jeeyoun;Lee, Seungeun;Park, Songmi;Oh, Yeonji;Lee, Sundong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.145-159
    • /
    • 2016
  • Objectives : The aim was to investigate the characteristics of low dose effect and non monotonic dose responses(NMDRs) and to predict the influence it might have on the health and medicine, traditional Korean medicine. Methods : By investigating recently published major literatures related to low dose effect and NMDRs, the definition, mechanism, major related fields, and the influence on public health and medicine has been categorized and summarized. Results : Although there are still heated debates about the definition of low dose, it implies the biological responses in environmental exposure level and the NDMDRs means the nonlinear relationship between the dose-response in the slope sign change. Also, it implies the new form of the curve showing a U, reverse U shape, and the slop sign constantly changing showing various forms. This mechanism is because the two acceptor shows opposing effects to toxic materials and the affinity is different along with the numerical value that increase and decrease being different. These characteristics generally appear in endocrine disrupters such as bisphenol A, agricultural pesticides, metal, and radiation. The research field in the public health and medical treatment is obesity, problems in metabolism, growth hormone treatment, climacteric treatment, breast cancer, intake of Korean traditional medicine for pregnancy, menopause and phytoestrogen. Conclusions : As a result of discussing implications, NMDRs is a particular effect in low dose and heated debates surround this response, research is being conducted surrounding the field of obesity, problems in metabolism, growth hormone treatment, climacteric treatment, breast cancer, intake of Korean traditional medicine for pregnancy, menopause, and phytoestrogen. More research and interest in needed as it can have a massive influence in the public health and medicine.

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.