• Title/Summary/Keyword: Breast dose

Search Result 541, Processing Time 0.021 seconds

Analysis of breast shielding rate of bismuth shield (비스무스 차폐체의 유방 차폐율 분석)

  • Kim, Jae Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1132-1137
    • /
    • 2020
  • In order to reduce unnecessary exposure doses generated when mammography is performed using a mammography device, a shielding ratio analysis was performed when a self-made shielding body made of bismuth was applied to the breast opposite to the imaging site. In order to determine the scattering dose of uncompressed breasts during CC and MLO tests when the right and left are compressed, the experiment is divided into when bismuth is not shielded (Not used: NU group) and when shielded (Used: U group). Proceeded. The average dose of the NU group was 9.568μSv, and the average dose of the U group was 1.038μSv. The average measured dose before and after the use of the bismuth shield was reduced by 89.15%. The use of a bismuth shield for mammography can shield scattered radiation and keep exposure to radiation to a minimum.

Internal Mammary Lymph Node Irradiation after Breast Conservation Surgery: Radiation Pneumonitis versus Dose-Volume Histogram Parameters (유방보존술 후 내유림프절 방사선 조사: 방사선 폐렴과 체적-선량 히스토그램 변수들)

  • Kim, Joo-Young;Lee, Ik-Jae;Keum, Ki-Chang;Kim, Yong-Bae;Shim, Su-Jung;Jeong, Kyoung-Keun;Kim, Jong-Dae;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • Purpose: To evaluate the association between radiation pneumonitis and dose-volume histogram parameters and to provide practical guidelines to prevent radiation pneumonitis following radiotherapy administered for breast cancer including internal mammary lymph nodes. Materials and Methods: Twenty patients with early breast cancer who underwent a partial mastectomy were involved in this study. The entire breast, supraclavicular lymph nodes, and internal mammary lymph nodes were irradiated with a dose of 50.4 Gy in 28 fractions. Radiation pneumonitis was assessed by both radiological pulmonary change (RPC) and by evaluation of symptomatic radiation pneumonitis. Dose-volume histogram parameters were compared between patients with grade <2 RPC and those with grade ${\geq}$2 RPC. The parameters were the mean lung dose, V10 (percent lung volume receiving equal to and more than 10 Gy), V20, V30, V40, and normal tissue complication probability (NTCP). Results: Of the 20 patients, 9 (45%) developed grade 2 RPC and 11 (55%) did not develop RPC (grade 0). Only one patient developed grade 1 symptomatic radiation pneumonitis. Univariate analysis showed that among the dose-volume histogram parameters, NTCP was significantly different between the two RPC grade groups (p<0.05). Fisher's exact test indicated that an NTCP value of 45% was appropriate as an RPC threshold level. Conclusion: This study shows that NTCP can be used as a predictor of RPC after radiotherapy of the internal mammary lymph nodes in breast cancer. Clinically, it indicates that an RPC is likely to develop when the NTCP is greater than 45%.

Reduced Ovarian Cancer Incidence in Women Exposed to Low Dose Ionizing Background Radiation or Radiation to the Ovaries after Treatment for Breast Cancer or Rectosigmoid Cancer

  • Lehrer, Steven;Green, Sheryl;Rosenzweig, Kenneth E
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2979-2982
    • /
    • 2016
  • Background: High dose ionizing radiation can induce ovarian cancer, but the effect of low dose radiation on the development of ovarian cancer has not been extensively studied. We evaluated the effect of low dose radiation and total background radiation, and the radiation delivered to the ovaries during the treatment of rectosigmoid cancer and breast cancer on ovarian cancer incidence. Materials and Methods: Background radiation measurements are from Assessment of Variations in Radiation Exposure in the United States, 2011. Ovarian cancer incidence data are from the Centers for Disease Control and Prevention. Standardized incidence ratios (SIR) of ovarian cancer following breast cancer and rectosigmoid cancer are from Surveillance, Epidemiology, and End Results (SEER) data. Obesity data by US state are from the Centers for Disease Control and Prevention. Mean ages of US state populations are from the United States Census Bureau. Results: We calculated standardized incidence ratios (SIR) from Surveillance, Epidemiology, and End Results (SEER) data, which reveal that in 194,042 cases of breast cancer treated with beam radiation, there were 796 cases of ovarian cancer by 120+ months of treatment (0.41%); in 283, 875 cases of breast cancer not treated with radiation, there were 1,531 cases of ovarian cancer by 120+ months (0.54%). The difference in ovarian cancer incidence in the two groups was significant (p < 0.001, two tailed Fisher exact test). The small dose of scattered ovarian radiation (about 3.09 cGy) from beam radiation to the breast appears to have reduced the risk of ovarian cancer by 24%. In 13,099 cases of rectal or rectosigmoid junction cancer treated with beam radiation in the SEER data, there were 20 cases of ovarian cancer by 120+ months of treatment (0.15%). In 33,305 cases of rectal or rectosigmoid junction cancer not treated with radiation, there were 91 cases of ovarian cancer by 120+ months (0.27%). The difference in ovarian cancer incidence in the two groups was significant (p = 0.017, two tailed Fisher exact test). In other words, the beam radiation to rectum and rectosigmoid that also reached the ovaries reduced the risk of ovarian cancer by 44%. In addition, there was a significant inverse relationship between ovarian cancer in white women and radon background radiation (r = - 0.465. p = 0.002) and total background radiation (r = -0.456, p = 0.002). Because increasing age and obesity are risk factors for ovarian cancer, multivariate linear regression was performed. The inverse relationship between ovarian cancer incidence and radon background was significant (${\beta}=-0.463$, p = 0.002) but unrelated to age (${\beta}=-0.080$, p = 0.570) or obesity (${\beta}=-0.180$, p = 0.208). Conclusions: The reduction of ovarian cancer risk following low dose radiation may be the result of radiation hormesis. Hormesis is a favorable biological response to low toxin exposure. A pollutant or toxin demonstrating hormesis has the opposite effect in small doses as in large doses. In the case of radiation, large doses are carcinogenic. However, lower overall cancer rates are found in U.S. states with high impact radiation. Moreover, there is reduced lung cancer incidence in high radiation background US states where nuclear weapons testing was done. Women at increased risk of ovarian cancer have two choices. They may be closely followed (surveillance) or undergo immediate prophylactic bilateral salpingo-oophorectomy. However, the efficacy of surveillance is questionable. Bilateral salpingo-oophorectomy is considered preferable, although it carries the risk of surgical complications. The data analysis above suggests that low-dose pelvic irradiation might be a good third choice to reduce ovarian cancer risk. Further studies would be worthwhile to establish the lowest optimum radiation dose.

Study on dose comparison using X-Jaw split in VMAT treatment planning for left breast cancer including supraclavicular lymph nodes. (쇄골 상부 림프절을 포함하는 왼쪽 유방암의 VMAT 치료계획시 X-Jaw split을 이용한 선량비교에 관한 연구)

  • Kim, Hak Jun;Lee, Yang Hoon;Min, Jae Soon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.137-144
    • /
    • 2021
  • Purpose : The usability of X-Jaw split VMAT was evaluated by comparative analysis of the dose distribution between the treatment plan divided by X-Jaw and Full field VMAT treatment plan in left breast cancer treatment including supraclavicular lymph nodes. Materials and Methods : 10 patients with left breast cancer, including supraclavicular lymph nodes, were simulated using vacuum cushion, and 2 Full field Arc VMAT and 4 X-Jaw split Arc VMAT were planned The treatment plan was designed to include more than 95% of the Planning Target Volume (PTV) and to be minimally irradiated in the surrounding Organ at risk (OAR). Dose analysis of PTV and OAR was performed through dose volume histogram (DVH). Results : The Full field VMAT treatment plan and the X-Jaw split VMAT treatment plan of 10 patients were expressed as average values and compared. The difference between the two treatment plans was not large, with a Conformity index (CI) of 1.05±0.04, 1.04±0.03, and a Homogeneity index (HI) of 1.07±0.008, 1.07±0.009. For OAR, V5 in the left lung is 56.1±6.50%, 50.4±6.30%, and V20 is 20.0±4.15%, 13.52±3.61%. Compared to Full field VMAT, V5 decreased by 10.0% V20 by 32.6% in X-Jaw split VMAT. The V30 of the heart is 3.68±1.85%, 2.23±1.52%, and the Mean dose is 8.93±1.65 Gy, 7.67±1.52 Gy. In the X-Jaw split VMAT, V30 decreased by 39.3% and the Mean dose decreased by 14.1%. The left lung and heart, which are normal tissues, were found to have a statistical significance of that p-value is less than 0.05. Conclusion : In the case of left breast cancer treatment, which includes Supraclavicular lymph nodes with a large PTV volume and a length of X Jaw of 15 cm or more, the X-Jaw split VMAT shows improved dose distribution, which can reduce radiation dose of OAR such as lungs and heart, while maintaining similar PTV coverage with HI and CI equivalent to Full field VMAT. It is thought to be effective in reducing radiation complications.

Kaiso represses the expression of glucocorticoid receptor via a methylation-dependent mechanism and attenuates the anti-apoptotic activity of glucocorticoids in breast cancer cells

  • Zhou, Lin;Zhong, Yan;Yang, Fang-hui;Li, Zi-bo;Zhou, Jiang;Liu, Xie-hong;Li, Min;Hu, Fang
    • BMB Reports
    • /
    • v.49 no.3
    • /
    • pp.167-172
    • /
    • 2016
  • Kaiso is a Pox Virus and Zinc Finger (POZ-ZF) transcription factor with bi-modal DNA-binding specificity. Here, we demonstrated that Kaiso expression is inversely correlated with glucocorticoid receptor (GR) expression in breast carcinomas. Knockdown of Kaiso increased GR expression, while overexpression of Kaiso inhibited GR expression in breast cancer cells. Furthermore, Kaiso repressed GR proximal promoter-reporter activity in a dose-dependent manner. Remarkably, ChIP experiments demonstrated that endogenous Kaiso was associated with the GR promoter sequence in a methylation-dependent manner. Since glucocorticoids inhibit chemotherapyinduced apoptosis and have been widely used as a co-treatment of patients with breast cancer, we assessed the role of Kasio in GR-mediated anti-apoptotic effects. We found that overexpression of Kaiso attenuated the anti-apoptotic effects of glucocorticoids in breast cancer cells. Our findings suggest that GR is a putative target gene of Kaiso and suggest Kaiso to be a potential therapeutic target in GC-combination chemotherapy in breast cancer.

Pristimerin Inhibits Breast Cancer Cell Migration by Up-regulating Regulator of G Protein Signaling 4 Expression

  • Mu, Xian-Min;Shi, Wei;Sun, Li-Xin;Li, Han;Wang, Yu-Rong;Jiang, Zhen-Zhou;Zhang, Lu-Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1097-1104
    • /
    • 2012
  • Background/Aim: Pristimerin isolated from Celastrus and Maytenus spp can inhibit proteasome activity. However, whether pristimerin can modulate cancer metastasis is unknown. Methods: The impacts of pristimerin on the purified and intracellular chymotrypsin proteasomal activity, the levels of regulator of G protein signaling 4 (RGS 4) expression and breast cancer cell lamellipodia formation, and the migration and invasion were determined by enzymatic, Western blot, immunofluorescent, and transwell assays, respectively. Results: We found that pristimerin inhibited human chymotrypsin proteasomal activity in MDA-MB-231 cells in a dose-dependent manner. Pristimerin also inhibited breast cancer cell lamellipodia formation, migration, and invasion in vitro by up-regulating RGS4 expression. Thus, knockdown of RGS4 attenuated pristimerin-mediated inhibition of breast cancer cell migration and invasion. Furthermore, pristimerin inhibited growth and invasion of implanted breast tumors in mice. Conclusion: Pristmerin inhibits proteasomal activity and increases the levels of RGS4, inhibiting the migration and invasion of breast cancer cells.

No Increase in Breast Cancer Risk in Japanese Women Taking Oral Contraceptives: a Case-Control Study Investigating Reproductive, Menstrual and Familial Risk Factors for Breast Cancer

  • Ichida, Miho;Kataoka, Akemi;Tsushima, Ruriko;Taguchi, Tetsuya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3685-3690
    • /
    • 2015
  • Background: Low-dose oral contraceptives (OC) were approved by the Japanese Ministry of Health, Labor and Welfare in 1999, yet despite their contraceptive and non-contraceptive health benefits, only 5% of the target population use them. Fear of increased cancer risk, particularly breast cancer, is one reason for this. Due to low OC uptake and low screening participation, a paucity of data is available on the risk of OC use and breast cancer in Japanese women. The present study investigated OC use and breast cancer risk, as well as menstrual, reproductive and family factors. Materials and Methods: This was a clinic-based case-control study of women aged 20-69yrs who had undergone breast screening between January 2007 and December 2013 in central Tokyo. In all, 28.8% of the participants had experience with OC use. Cases were 155 women with a pathologically confirmed diagnosis of breast cancer. Controls were the remaining 12,333 women. Results: Increased age was a significant risk factor for breast cancer (p<0.001). A lower risk was found in premenopausal women presently taking OC compared to never users (OR 0.45; 95% CI 0.22-0.90) after adjusting for age, parity and breast feeding, and a family history of breast cancer. Conclusions: Increased age rather than OC use had a greater effect on breast cancer risk. This risk may be decreased in premenopausal women with OC use, but further long-term prospective studies are necessary.

Quality Assurance of Intensity Modulated Radiation Therapy: Site-Specific Results of Eulji University Hospital (질환별 세기조절방사선치료의 정도관리: 을지대학병원 임상결과)

  • Kim, Sung-Jin;Lee, Mi-Jo;Youn, Seon-Min
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.99-106
    • /
    • 2011
  • Purpose: To analyze our quality assurance (QA) data for intensity modulated radiation therapy (IMRT) according to treatment site and to possibly improve QA for IMRT in Hospital. Materials and Methods: We performed QA on 50 patients (head and neck, 28 patients; Breast, 14 patients; Pelvis, 8 patients) for IMRT. The calculated dose from RTP was compared with the measured value film, gamma index, and ionization chamber for dose measurement in each case. Results: The point dose measurement results in 45 of 50 patients showed good agreement with the calculation dose (${\pm}3%$). The largest error measured thus far has been 3.60%, with a mean of only -0.17% (SD, 2.25%). Each treatment site showed an error rate of -0.13% (SD, 1.93%) for head and neck cases, -0.26% (SD, 2.79%) for breast cases, and 0.24% (SD, 2.44%) for pelvis cases. The gamma index verified with the error rate of head and neck cases (6%), breast (10%), and pelvis (6%), which corresponded to a tolerance of 3 mm (3% for the head and neck, 2%, for the breast 1% for the pelvis, and 0% in the region where the isodose curve was greater than 90%. Conclusion: We recognize the cause of errors for each treatment site of IMRT QA and so we maximize our efforts to reduce error and increase accuracy.

The Comparison of Dose Distribution on Radiation Therapy between IMRT and VMAT in Modified Radical Mastectomy Patients (전유방절제술 환자에서 IMRT와 VMAT을 이용한 방사선치료시 선량 분포의 비교)

  • Ko, Hye-Jin;Kim, Young-Jae;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.8
    • /
    • pp.225-232
    • /
    • 2014
  • Underwent on modified radical mastectomy(MRM) and radiation therapy, it affects increasing rates of chronic morbidity, because of including chest wall and internal mammary nodes(IMNs). It causes the high absorbed dose on heart and ipsilateral lung. Thus in this study, we compared dose distributions through utilizing the intensity modulated radiation therapy(IMRT) and the volumetric modulated arc therapy(VMAT). We selected 10 breast cancer patients at random who took MRM and radiation therapy. Treatment plannings were done by using IMRT and VMAT from each patient ranging supraclavicular lymphnodes(SCL) and IMNs. After that we analysed the planning target volume(PTV)'s conformity and absorbed doses on heart and lungs. As a results, PTV conformities were indicated the same patten(p<0.05) in both plans. In case of Lt breast cancer patients, the dose maximum regions of the heart were more lesser in VMAT technique rather than the IMRT(p<0.05). Also, the maximum dose areas of lungs were lesser in VMAT technique rather than the IMRT(p<0.05). Therefore, it would be safe to say that it is more effective way to adapt the VMAT technique than IMRT in such cases like involve IMNs in breast cancer patients.

Dosimetric Characteristics of Dynamic Wedge Technique (Dynamic Wedge의 조직내 방사선량 분포의 특성)

  • Oh Young Taek;Keum Ki Chang;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.323-332
    • /
    • 1996
  • Purpose : The wedge filter is the most commonly used beam modifying device during radiation therapy Recently dynamic wedge technique is available through the computer controlled asymmetric collimator, independent jaw. But dosimetric characteristics of dynamic wedge technique is not well known. Therefore we evaluate dosimetric characteristics of dynamic wedge compared to conventional fixed wedge. Materials and Methods : We evaluated dosimetric characteristics of dynamic wedge and fixed wedge by ion chamber, film dosimetry and TLD in phantoms such as water, polystyrene and average breast phantom. Six MV x-ray was used in $15{\times}15cm$ field with 15,30 and 45 degree wedge of dynamic/liked wedge system, Dosimeric characteristics are interpreted by Wellhofer Dosimetrie system WP700/WP700i and contralateral breast dose (CBD) with tangential technique was confirmed by TLD. Results : 1) Percent depth dose through the dynamic wedge technique in tissue equivalent phantom was similar to open field irradiation and there was no beam hardening effect compared to fixed wedge technique. 2) Isodose line composing wedge angle of dynamic wedge is more straight than hard wedge. And dynamic wedge technique was able to make any wedge angle on any depth and field size. 3) The contralateral breast dose in primary breast irradiation was reduced by dynamic wedge technique compared to fixed wedge. When the dynamic wedge technique was applied, the scatter dose was similar to that of open field irradiation. Conclusion : The dynamic wedge technique was superior to fixed wedge technique in dosimetric characteristics and may be more useful in the future.

  • PDF