• Title/Summary/Keyword: Breast biopsy

Search Result 197, Processing Time 0.031 seconds

Successful First Round Results of a Turkish Breast Cancer Screening Program with Mammography in Bahcesehir, Istanbul

  • Kayhan, Arda;Gurdal, Sibel Ozkan;Ozaydin, Nilufer;Cabioglu, Neslihan;Ozturk, Enis;Ozcinar, Beyza;Aribal, Erkin;Ozmen, Vahit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1693-1697
    • /
    • 2014
  • Background: The Bahcesehir Breast Cancer Screening Project is the first organized population based breast cancer mammographic screening project in Turkey. The objective of this prospective observational study was to demonstrate the feasibility of a screening program in a developing country and to determine the appropriate age (40 or 50 years old) to start with screening in Turkish women. Materials and Methods: Between January 2009 to December 2010, a total of 3,758 women aged 40-69 years were recruited in this prospective study. Screening was conducted biannually, and five rounds were planned. After clinical breast examination (CBE), two-view mammograms were obtained. True positivity, false positivity, positive predictive values (PPV) according to ACR, cancer detection rate, minimal cancer detection rate, axillary node positivity and recall rate were calculated. Breast ultrasound and biopsy were performed in suspicious cases. Results: Breast biopsy was performed in 55 patients, and 18 cancers were detected in the first round. The overall cancer detection rate was 4.8 per 1,000 women. Most of the screened women (54%) and detected cancers (56%) were in women aged 40-49. Ductal carcinoma in situ (DCIS) and stage I cancer and axillary node positivity rates were 22%, 61%, and 16.6%, respectively. The positive predictivity for biopsy was 32.7%, whereas the overall recall rate was 18.4 %. Conclusions: Preliminary results of the study suggest that population based organized screening are feasible and age of onset of mammographic screening should be 40 years in Turkey.

Clinical Application of $^{18}F-FDG$ PET in Breast Cancer (유방암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yoon, Joon-Kee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.76-90
    • /
    • 2008
  • $^{18}F-FDG$ PET in combination with conventional imaging modalities could help avoid unnecessary biopsy for the primary mass, and it also has a high diagnostic accuracy in patients with dense breasts. In the assessment of metastasis, $^{18}F-FDG$ PET was useful to select patients who required sentinel lymph node biopsy and to detect extra-axillary lymph node metastasis and distant metastasis. To increase the sensitivity for osteoblastic bone metastasis, bone scintigraphy should be added. In the detection of recurrence, $^{18}F-FDG$ PET showed a higher diagnostic accuracy than tumor marker or computed tomography, and therefore it can be used in routine breast cancer follow-up. $^{18}F-FDG$ PET has been reported that it correctly predicted the response of neoadjuvant chemotherapy on as early as 8th day of treatment. Therefore, it is useful for the early detect of therapeutic response in advanced breast cancer.

Comparison of Shear Wave Elastography and Pathologic Results Using BI - RADS Category for Breast Mass (유방종괴에 대한 BI-RADS범주를 이용한 횡탄성 초음파와 병리결과 비교분석)

  • An, Hyun;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.217-223
    • /
    • 2018
  • This study to search the diagnostic performance of shear wave elastography(SWE) in breast mass and to compare the biopsy result and stiffness obtained from shear wave elastography. Diagnostic breast ultrasonography and SWE were targeted for 157 patients who had breast ultrasonography was diagnosed mass from June 2017 to September 2017. Pathology results of 157 patients showed a benign 92 patients(Age, $44.54{\pm}11.84$) and a malignancy 65 patients(Age, $51.55{\pm}10.54$). Final evaluation, biopsy result, and quantitative SWE result were obtained and compared with each other according to Breast Imaging Reporting and Data System(BI-RADS) of diagnostic breast ultrasonography. Quantitative SWE value and pathologic result showed the highest diagnostic specificity of 83.70% in Emean and sensitivity of 89.23% in Emin. Quantitative SWE result and biopsy result is statistically significant.(p=0.000). The optimal cut-off value for malignant lesions was 66.3 kPa and 63.7 kPa, respectively, for the sensitivity, specificity, high maximum mean elasticity value(Emax) and mean elasticity value(Emean) and this showed the highest diagnostic area under the ROC curve(Az) value compared to other SWE measurement(p=0.000). The addition of SWE to conventional US in breast mass make a increase diagnostic specificity and reduce unnecessary biopsy. Therefore, it is expected that it will be helpful to analyze the breast mass using the above analysis and apparatus.

US-guided 14G Core Needle Biopsy: Comparison Between Underestimated and Correctly Diagnosed Breast Cancers

  • Kim, Hana;Youk, Ji Hyun;Kim, Jeong-Ah;Gweon, Hye Mi;Jung, Woo-Hee;Son, Eun Ju
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3179-3183
    • /
    • 2014
  • Background: The purpose of study was to evaluate radiologic or clinical features of breast cancer undergoing ultrasound (US)-guided 14G core needle biopsy (CNB) and analyze the differences between underestimated and accurately diagnosed groups. Materials and Methods: Of 1,898 cases of US-guided 14G CNB in our institute, 233 cases were proven to be cancer by surgical pathology. The pathologic results from CNB were invasive ductal carcinoma (IDC) (n=157), ductal carcinoma in situ (DCIS) (n=40), high-risk lesions in 22 cases, and benign in 14 cases. Among high-risk lesions, 7 cases of atypical ductal hyperplasia (ADH) were reported as cancer and 11 cases of DCIS were proven IDC in surgical pathology. Some 29 DCIS cases and 157 cases of IDC were correctly diagnosed with CNB. The clinical and imaging features between underestimated and accurately diagnosed breast cancers were compared. Results: Of 233 cancer cases, underestimation occurred in 18 lesions (7.7%). Among underestimated cancers, CNB proven ADH (n=2) and DCIS (n=11) were diagnosed as IDC and CNB proven ADH (n=5) were diagnosed at DCIS finally. Among the 186 accurately diagnosed group, the CNB results were IDC (n=157) and DCIS (n=29). Comparison of underestimated and accurately diagnosed groups for BI-RADS category, margin of mass on mammography and US and orientation of lesion on US revealed statistically significant differences. Conclusions: Underestimation of US-guided 14G CNB occurred in 7.7% of breast cancers. Between underestimated and correctly diagnosed groups, BI-RADS category, margin of the mass on mammography and margin and orientation of the lesions on US were different.

Role of MRI in Diagnostic Evaluation of Papillary Lesions of the Breast (유방의 유두상 병변의 진단에서 자기공명영상의 역할)

  • Lee, So-Mi;Kim, Hye-Jung;Gwak, Yeon-Joo;Lee, Hui-Joong;Jang, Yun-Jin;Shin, Kyung-Min;Park, Ji-Young;Jung, Jin-Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose : To evaluate the role of magnetic resonance imaging (MRI) in the diagnosis of papillary lesions of the breast. Materials and methods : Among 45 papillary lesions diagnosed at ultrasonography-guided core biopsy (USCB), 27 benign papillary lesions in 22 patients who underwent breast MRI were reviewed. The excsional biopsy was performed in 1-10 days after MRI was done. In MRI findings, lesions were considered suspicious if they show irregular, rim enhancement, or linear enhancement in morphologic evaluation, or washout enhancement pattern of delayed phase in dynamic enhancement characteristics. Diffusionweighted images were analyzed according to visibility of lesions. MRI findings were correlated with pathologic results at excisional biopsy. Results : At excisional biopsy, two lesions (9%) were diagnosed malignant in 22 benign papillary lesions without atypia by USCB and 4 (80%) were malignant in 5 benign papillary lesions with atypia by USCB. Among 18 lesions detected on MRI, 16 lesions showed suspicious findings on MRI, 11 lesions (69%) were diagnosed as benign and 5 (31%) were malignant. Among 12 lesions detected on diffusion weighted imaging, 10 lesions were diagnosed as benign and 2 were malignant. MRI findings were not significantly correlated with pathologic results at excisional biopsy. Conclusion : MRI findings were not useful to predict malignancy in benign papillary lesions diagnosed at USCB, because MRI findings of these were mostly suspicious (88.9%, 16/18). The benign papillary lesion should be included in the false positive lesion on breast MRI.

Fine Needle Aspiration Biopsy Cytology of Breast Tumors (세침 천자 검사로 진단된 유방종양의 세포병리학적 연구)

  • Kim, In-Sook;Lee, Jung-Dal
    • The Korean Journal of Cytopathology
    • /
    • v.1 no.1
    • /
    • pp.51-59
    • /
    • 1990
  • Fine needle aspiration biopsy cytology (FNA) for diagnosis of a variety of breast tumors has been proven to be a simple, safe, and cost saving diagnostic methodology with high accuracy. Cytologic specimens from 1,029 fine needle aspirations of the breast during last 3-year period were reviewed and subsequent biopsies from 107 breast lesions were reevaluated for cytohistological correlation. FNA had a sensitivity of 81.6% and a specificity of 98.3%. One oui of 107 cases biopsied revealed a false positive result (0.9%) and the case was due to misinterpretation of apocrine metaplastic cells in necrotic backgound as malignant cells. A false negative rate was 8.4% (9 of 107 cases biopsied). Six of 9 false negative cases were resulted from insufficient aspirates for diagnosis, and remaining three of 9 false negative cases revealed extensive necrosis with no or scanty viable cells on smears. The results indicate that for reducing false positive and false negative rates of FNA, an experienced cytopathologist and a proficient aspirator are of great importance.

  • PDF

Clinical outcomes after sentinel lymph node biopsy in clinically node-negative breast cancer patients

  • Han, Hee Ji;Kim, Ju Ree;Nam, Hee Rim;Keum, Ki Chang;Suh, Chang Ok;Kim, Yong Bae
    • Radiation Oncology Journal
    • /
    • v.32 no.3
    • /
    • pp.132-137
    • /
    • 2014
  • Purpose: To evaluate non-sentinel lymph node (LN) status after sentinel lymph node biopsy (SNB) in patients with breast cancer and to identify the predictive factors for disease failure. Materials and Methods: From January 2006 to December 2007, axillary lymph node (ALN) dissection after SNB was performed for patients with primary invasive breast cancer who had no clinical evidence of LN metastasis. A total of 320 patients were treated with breast-conserving surgery and radiotherapy. Results: The median age of patients was 48 years, and the median follow-up time was 72.8 months. Close resection margin (RM) was observed in 13 patients. The median number of dissected SNB was two, and that of total retrieved ALNs was 11. Sentinel node accuracy was 94.7%, and the overall false negative rate (FNR) was 5.3%. Eleven patients experienced treatment failure. Local recurrence, regional LN recurrence, and distant metastasis were identified in 0.9%, 1.9%, and 2.8% of these patients, respectively. Sentinel LN status were not associated with locoregional recurrence (p > 0.05). Close RM was the only significant factor for disease-free survival (DFS) in univariate and multivariate analysis. The 5-year overall survival, DFS, and locoregional DFS were 100%, 96.8%, and 98.1%, respectively. Conclusion: In this study, SNB was performed with high accuracy and low FNR and high locoregional control was achieved.

Outcome and Cost Effectiveness of Ultrasonographically Guided Surgical Clip Placement for Tumor Localization in Patients undergoing Neo-adjuvant Chemotherapy for Breast Cancer

  • Masroor, Imrana;Zeeshan, Sana;Afzal, Shaista;Sufian, Saira Naz;Ali, Madeeha;Khan, Shaista;Ahmad, Khabir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8339-8343
    • /
    • 2016
  • Background: To determine the outcome and cost saving by placing ultrasound guided surgical clips for tumor localization in patients undergoing neo-adjuvant chemotherapy for breast cancer. Materials and Methods: This retrospective cross sectional analytical study was conducted at the Department of Diagnostic Radiology, Aga Khan University Hospital, Karachi, Pakistan from January to December 2014. A sample of 25 women fulfilling our selection criteria was taken. All patients came to our department for ultrasound guided core biopsy of suspicious breast lesions and clip placement in the index lesion prior to neo-adjuvant chemotherapy. All the selected patients had biopsy proven breast cancer. Results: The mean age was $45{\pm}11.6years$. There were no complications seen after clip placement in terms of clip migration or hemorrhage. The cost of commercially available markers was approximately PKR 9,000 (US$ 90) and that of the surgical clip was PKR 900 (US$ 9). The cost of surgical clips in 25 patients was PKR 22,500 (US$ 225), when compared to the commercially available markers which may have incurred a cost of PKR 225,000 (US$ 2,250). The total cost saving for 25 patients was PKR 202,500 (US$ 2, 025), making it PKR 8100 (US$ 81) per patient. Conclusions: The results of our study show that ultrasound guided surgical clip placement in index lesions prior to neo-adjuvant therapy is a safe and cost effective method to identify tumor bed and response to treatment for further management.

Methylene Blue Dye-Induced Skin Necrosis in Immediate Breast Reconstruction: Evaluation and Management

  • Lee, Ji Hwan;Chang, Choong Hyun;Park, Chan Heun;Kim, June-Kyu
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.258-263
    • /
    • 2014
  • Background For early breast cancer patients, skin-sparing mastectomy or nipple-sparing mastectomy with sentinel lymph node biopsy has become the mainstream treatment for immediate breast reconstruction in possible cases. However, a few cases of skin necrosis caused by methylene blue dye (MBD) used for sentinel lymph node localization have been reported. Methods Immediate breast reconstruction using a silicone implant was performed on 35 breasts of 34 patients after mastectomy. For sentinel lymph node localization, 1% MBD (3 mL) was injected into the subareolar area. The operation site was inspected in the postoperative evaluation. Results Six cases of immediate breast reconstruction using implants were complicated by methylene blue dye. One case of local infection was improved by conservative treatment. In two cases, partial necrosis and wound dehiscence of the incision areas were observed; thus, debridement and closure were performed. Of the three cases of wide skin necrosis, two cases underwent removal of the dead tissue and implants, followed by primary closure. In the other case, the breast implant was salvaged using latissimus dorsi musculocutaneous flap reconstruction. Conclusions The complications were caused by MBD toxicity, which aggravated blood disturbance and skin tension after implant insertion. When planning immediate breast reconstruction using silicone implants, complications of MBD should be discussed in detail prior to surgery, and appropriate management in the event of complications is required.

Background Parenchymal Enhancement on Breast MRI in Breast Cancer Patients : Impact on Biopsy Rate and Cancer Yield (유방암 환자에서 시행한 유방 자기공명영상에서 배경 실질 조영 증강이 조직검사율과 악성률에 미치는 영향)

  • Kim, Tae Yun;Kim, Sung Hun;Baik, Jee Eun;Kim, Yun Joo;Kang, Bong Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.224-231
    • /
    • 2013
  • Purpose : To evaluate the potential effects of background parenchymal enhancement of MR imaging in diagnosed breast cancer patients on the rate of additional biopsy and resultant cancer yield. Materials and Methods: 322 patients who were diagnosed with breast cancer and had undergone breast MR imaging were included in this study. Two radiologists reviewed the MRI for degree of background parenchymal enhancement and additional suspicious lesions described as BI-RADS category 4 or 5 on radiologic reports. Biopsy was done for these lesions, pathology reports were reviewed to calculate the cancer yield. Results: Background parenchymal enhancement of MR imaging in a total of 322 patients were classified as minimal degree 47.5%, mild degree 28.9%, moderate degree 12.4% and marked degree 11.2%. Among these 332 patients, MR imaging of 70 patients showed additional suspicious malignant lesions described as BI-RADS category 4 or 5, and consequently, 66 patients underwent biopsy. Biopsy rates in those with minimal or mild background parenchymal enhancement and those with moderate and marked background parenchymal enhancement were 19.9% and 22.3% (p-value 0.77) respectively. Cancer yields in those with minimal or mild background parenchymal enhancement and those with moderate and marked background parenchymal enhancement were 6.5% and 5.2% (p value 0.88) respectively. Both these results did not show stastically significant difference between the two groups. Conclusion: The degree of background parenchymal enhancement in MR imaging of breast cancer patients did not significantly impact additional biopsy rates or cancer yields.