• Title/Summary/Keyword: Breakthrough curves

Search Result 115, Processing Time 0.026 seconds

Modeling Study on Nuclide Transport in Ocean - an Ocean Compartment Model (해양에서의 핵종이동 모델링 - 해양구획 모델)

  • Lee, Youn-Myoung;Suh, Kyung-Suk;Han, Kyong-Won
    • Nuclear Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.387-400
    • /
    • 1991
  • An ocean compartment model simulating transport of nuclides by advection due to ocean circulation and intertaction with suspended sediments is developed, by which concentration breakthrough curves of nuclides can be calculated as a function of time. Dividing ocean into arbitrary number of characteristic compartments and performing a balance of mass of nuclides in each ocean compartment, the governing equation for the concentration in the ocean is obtained and a solution by the numerical integration is obtained. The integration method is specially useful for general stiff systems. For transfer coefficients describing advective transport between adjacent compartments by ocean circulation, the ocean turnover time is calculated by a two-dimensional numerical ocean model. To exemplify the compartment model, a reference case calculation for breakthrough curves of three nuclides in low-level radioactive wastes, Tc-99, Cs-137, and Pu-238 released from hypothetical repository under the seabed is carried out with five ocean compartments. Sensitivity analysis studies for some parameters to the concentration breakthrough curves are also made, which indicates that parameters such as ocean turnover time and ocean water volume of compartments have an important effect on the breakthrough curves.

  • PDF

Purification of Water Contaminants Using Activated Carbon Fiber Filter with Phenolic Resin Coated on Glass Fibers as a Precursor

  • Baek, Il-Hyun
    • Carbon letters
    • /
    • v.1 no.2
    • /
    • pp.82-86
    • /
    • 2000
  • The present research was undertaken to evaluate the possibility of water purification filter with activated carbon fibers (ACFs) using a very low cost precursor consisting of phenolic resin coated on glass fibers. The simplified procedure involving coating, curing and activation and a very low cost glass fiber as a raw material were adopted in order to reduce manufacturing cost. The breakthrough curves of the manufactured ACFs and the commercial activated carbon (AC, Calgon F-200) were investigated in the initial concentration range from 19 to 49 ppm for benzene, toluene and ethylbenzene. From breakthrough profiles, the manufactured ACFs had significantly faster adsorption kinetics than the AC. Especially the benzene breakthrough curves, the manufactured ACF (13 g of ACF with 32% of carbon on the glass) was over the limited level (5 ppb) after flowing of 32 l at initial concentration of 15 ppm, while the commercial AC was shown about 3 ppm in initial adsorption.

  • PDF

Breakthrough Behavior of Benzene and Toluene in Adsorption Bed (흡착탑에서 벤젠과 톨루엔의 파괴거동)

  • Kang, Sung-Won;Min, Byong-Hoon;Suh, Sung-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.83-88
    • /
    • 2000
  • The VOCs(Volatile Organic Compounds) is one of the major cause for the atmosphere pollution. Breakthrough behavior of benzene and toluene in adsorption bed packed with activated carbon was experimentally studied. Composition and temperature of the gas flowing in the bed was measured and breakthrough curves for each component was obtained. Breakthrough time of benzene was earlier than that of toluene due to relatively weak adsorptivity. The relationship between breakthrough time and flow rate was obtained. The shape of temperature change with time was dependent on the position in the bed. Temperature changed faster and sharper in the inlet than in the outlet. It was noted that breakthrough behavior could be affected by the heat transfer properties.

Measurement of mass Transfer Coefficients for Adsorptive Bulk Gas Separation with Velocity Variations (기체속도가 변하는 벌크기체의 흡착공정에서 물질전달계수의 측정)

  • Min, Jun-Ho;Choi, Min-Ho;Suh, Sung-Sup
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.310-318
    • /
    • 1999
  • The concentration breakthrough curves were examined to predict mass transfer coefficients of nitrogen and oxygen in adsorption column for design data of PSA process. Experimental breakthrough curves for bulk gas flow were compared with theoretical simulation results. For quantitative analysis of the adsorption, coupled Langmuir isotherm was considered and LDF model was used to describe the mass transfer effect. In the experimental and theoretical results, it was found that mass transfer coefficient was not affected by flow rate but strongly affected by pressure. As a result of this tendency, mass transfer resistance in this system was proved to belong to the macropore diffusion controlling region and the mass transfer coefficients could be expressed by exponential functions of pressure change. The mass transfer coefficients for one component, nitrogen or oxygen, were successfully applied to breakthrough curves for bulk mixed gases. The experimental curves were reasonably in consistent with the theoretical curves and the error time was less than 5 percent.

  • PDF

Breakthrough Characteristics for Lithium Ions Adsorption in Fixed-bed Column Packed with Activated Carbon by Modified with Nitric Acid (질산으로 개질한 활성탄을 충전한 고정층에서 리튬이온 흡착시의 파과특성)

  • Kam, Sang-Kyu;You, Hae-Na;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1143-1149
    • /
    • 2014
  • The adsorption experiments of lithium ions were conducted in the fixed bed column packed with activated carbon modified with nitric acid. Effect of inlet concentration, bed hight and flow rate on the removal of lithium ions was investigated. The experimental results showed that the removal and the adsorption capacity of lithium ions increased with increasing inlet concentration, and decreased with increasing flow rate. When the bed height increased, the removal and the adsorption capacity increased. The breakthrough curves gave a good fit to Bohart-Adams model. Adsorption capacity and breakthrough time calculated from Bohart-Adams model, these results were remarkably consistent with the experimental values. The adsorption capacity was not changed in the case of 3 times repetitive use of adsorbent.

Comparisons of Adsorption-Desorption Characteristics of Major 10 Kinds Components Consisting of Gasoline Vapor (유증기를 구성하는 주요 10종류 성분의 온도에 따른 흡·탈착특성 비교)

  • Lee, Song-Woo;Na, Young-Soo;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1593-1600
    • /
    • 2014
  • Adsorption and desorption characteristics of the representative 10 kinds components consisting of gasoline vapor on activated carbon were investigated at the temperature range of $-30^{\circ}C{\sim}25^{\circ}C$. The breakthrough curves of each vapors obtained by the Thomas model were well described the breakthrough experimental results of this study. The breakthrough times of each vapors were correlated with the molecular weight, density, and vapor pressure. The breakthrough times had greater correlation with boiling point than molecular weight and density. The slope of the breakthrough curve was a proportional relationship with the rate constant (k) of Thomas model expression. The higher the slope of the breakthrough curve, the rate constant was larger. The biggest slope vapor had the smallest adsorption capacity ($q_e$). Adsorption and desorption characteristics of mixed vapor similar to the gasoline vapor were studied at room temperature ($25^{\circ}C$). The mixed vapor consisting of 9 components; group A (pentane, hexene, hexane), group B (benzene, toluene), group C (octane, ethylbenzene, xylene, nonane) was examined. Group A was not nearly adsorbed because of substitution by group C, and the desorption capacity of group A was smaller than group C. The adsorbed substances were confirmed to be Group C.

Removal of Dissolved Organic Matters in Drinking Water by GAC adsorption using RSSCT (RSSCT를 이용한 GAC의 상수원수 내 용존유기물질 제거)

  • Kim, Young Il;Bae, Byung Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.727-736
    • /
    • 2006
  • Granular activated carbon (GAC) has been identified as a best available technology (BAT) by the United States Environmental Protection Agency (USEPA) for removal disinfection by-product (DBP) precursors, such as dissolved organic carbon (DOC) and dissolved organic nitrogen (DON). Rapid small-scale column test (RSSCT) were used to investigate four types of carbon (F400, Norit1240, Norit40S, and Aquasorb1500) for their affinity to absorb natural organic matter (NOM). DOC, $UV_{254}$, and Total dissolved nitrogen (TON) concentrations were measured in the column effluent to track GAC breakthrough. DOC and $UV_{254}$ breakthrough occurred at around 3500 bed volumes (BVs) of operation for all GACs investigated. The $UV_{254}$ breakthrough curves showed 33% to 48% at 8000 BVs, when the DOC was 48% to 65%. All GACs showed greater removal in DOC than $UV_{254}$. The NORIT1240 GAC was determined to have the highest adsorption capacity for DOC and $UV_{254}$. The removal of nitrate (NOTN) had not broken through over BVs. The initial TON breakthrough curves were started around 50%, when the DOC breakthrough was only 10 % at 500 BVs. The curves were gradually increased after 3500 BVs and approximately 69% through 81% of TON breakthrough occurred at 8000 BVs. All of the GACs were able to remove TON, in the case of this investigation the majority of the TON was present as DON. Because nitrate nitrogen was seldom removed and ammonium nitrogen ($NH_3-N$) was not detected in the effluent from RSSCTs even though raw water. The carbon usage rate of DOC was from 2 to 6 times less than that of TON. The NORIT1240 GAC demonstrated the best performance in terms of DOC removal, while the F400 GAC was best in terms of TON removal. Excitation emission matrix(EEM) analysis was used to show that GAC adsorption successfully removed most of Humic-like DOC and Fulvic-like DOCs. However, soluble microbial product(SMP)-like DOC in the absence of raw water were detected in the NORIT40S and Aquasorb1500 GAC. The authors assumed that this results is due probably to the part of GAC in the RSSCT which was converted into biological activated carbon(BAC). To compare with organics removal by GAC according to preloading, the virgin GACs had readily accessible sites that were adsorbed DOC more rapidly than preloaded GACs, but the TDN removal had not showed differences between those GACs.

COMPARISON OF FLUX AND RESIDENT CONCENTRATION BREAKTHROUGH CURVES (BTCs) IN STRUCTURED SOIL COLUMNS

  • Kim, Dong-Ju
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.05a
    • /
    • pp.25-29
    • /
    • 1997
  • In many solute transport studies, either flux or resident concentration has been used. Choice of the concentration mode was dependent on the monitoring device in solute displacement experiments. It would be questionable, however. to accept the equivalency in the solute transport parameters between flux and resident concentrations in structured soils exhibiting preferential movement of solute. In this study, we investigate how they differ in the monitored breakthrough curves (BTCs) and transport parameters for a given boundary and flow condition by performing solute displacement experiments on a number of undisturbed soil columns. Both flux and resident concentrations have been simultaneously obtained by monitoring the effluent and resistance of the Horizontally-positioned TDR probes. The study reveals that soil columns having relatively high flux densities exhibited great differences in the degree of peak concentration and travel time of peak between flux and resident concentrations. The peak concentration in flux mode was several times higher than that in resident one. This was mainly due to the bypassing of solute through soil macropores.

  • PDF

Analysis of Higher Temporal Moments for Breakthrough Curves of Volatile Organic Compounds in Unsaturated Soil (불포화 토양에서 유동하는 가스상 Volatile Organic Compounds의 출현곡선에 대한 고차 Temporal Moment의 분석)

  • Kim, Heon-Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.60-69
    • /
    • 2007
  • Understanding the behavior of gas phase VOCs (volatile organic compounds) in unsaturated soils is of a great environmental importance for public health concerns. Moment analysis for the breakthrough curves (BTCs) during transport of chemicals in porous media was known to be a useful tool to evaluate the velocity, spreadness, and the skewness of the plume of the chemicals. In this study, the temporal moments of the BTCs of a group of VOCs were analyzed for the gaseous transport in an unsaturated soil. BTCs were measured using lab-scale column experiments for four different VOCs at the water saturation range of 0.04-0.46, and for eleven VOCs at a water saturation of 0.21. The central second and third moments of the VOCs were compared with the water saturation and the first moment. It was found that both central second and third moments increased with the first moment. The central third moment was, however, found to be more sensitive to the first moment.

Adsorption of Gaseous Benzene onto Mesoporous Silicates (메조포러스 실리케이트에 의한 기상 벤젠 흡착)

  • Lee, Chae Young;Moon, Nam Gu;Chung, Jin Suk;Shin, Eun Woo
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.452-456
    • /
    • 2008
  • Mesoporous silicate materials have been used as adsorbents due to the advantage of high specific surface area and regular mesopores. In this study, conventional mesoporous silicates (MCM-41, and SBA-15) were utilized as adsorbents for gaseous benzene, one of volatile organic compounds. In the results of the breakthrough curves of gaseous benzene, SBA-15 showed a higher benzene adsorption capacity in adsorption condition of this study. Especially, compared to benzene adsorption of zeolite X, that of SBA-15 was higher by a factor of 2.7. With increasing adsorption temperature, adsorption capacity for benzene of SBA-15 was decreased rapidly. This indicates that benzene adsorbed weakly on SBA-15.