• Title/Summary/Keyword: Breaking Strength

Search Result 468, Processing Time 0.026 seconds

Reological Studies on Cocoon Filament II. Changes of strength and elongation at breaking related to the stretching speed and swelling degree (견사의 탄성적성질에 관한 연구 II. 인장속도 및 팽윤에 따른 파괴강신도의 변화)

  • 남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.14 no.2
    • /
    • pp.105-112
    • /
    • 1972
  • The effects of the stretching speed and the swelling degree of cocoon filaments on load-elongation curve were tested by tensilon with special attachments. The values of breaking strength, elongation at break and initial tensile strength obtained from load elongation curves are summarized as follows; 1. The breaking strength of the swollen cocoon filament appeared to increase at the high stretching speed, while elongation at break decreased. 2. Load-elongation curve became crinkled at the low speed of stretching. It suggests that both slip and break of the macrofibrils may occur in swelling of cocoon bave. 3. Breaking strength appeared to considerably decrease and elongation at break not to increase in swelling test at 9$0^{\circ}C$ for 60 min. 4. The initial tensile strength was influenced by the stretching speed and swelling degree of cocoon filaments.

  • PDF

An Experimental Study on the Fracture Characteristics of Wire Ropes (와이어 로프의 파단특성에 관한 실험적 연구)

  • 김종현;이근오;태순호
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.3-10
    • /
    • 1994
  • This study examines fracture characteristics of wire rope of 6$\times$37+FC 14mm B degree, Which has been widely used for the strength support for machinery, cranes and shipping. The examination Is based on the fellowing experimental conditions. Firstly, this study analyzes the effect of the strength of wlre rope. When number of broken wires is occuring at the level of 5%, 10% and 15% degree respectively in the following two cases:1) Case of broken down to each strand equally. 2) Case of broken down to one strand only. Secondly, this study analyzes the effect of corrosion on the strength of wire rope. Corrosion times are 72hours, 144hours and 216hours corrosion respectively under following conditions. 1) Case of only a corrosion without wire breaking. 2) Case of corrosion after 5% degree wire breaking to each strand equally. Some outcomes of these experiment are as follows. 1) From the of tension test, We can find that the ratio of strength reduction case of wire broke down to one strand concentrically is greater than that ratio case of broke down to each strand equally. 2) From the corrosion test, We can also find that the ratio of strength reduction case of corroded after 5% degree wire breaking to each strand equally Is greater than that ratio case of corroded without wire breaking. 3) After comparing theoretical fracture load of wires with experimental fracture load of wires, we can find the fracture load of the case of broken down to each strand equally is most similar to theoretical fracture load. 4) It is proposed that safety rules on wire rope in the Industrial safety and healthy labor of law have to change “breaking over 10% of number of wires in one strand of wire rope(excluded filler wire )”has to be replaced by“breaking over 10% of number of all wires in all strand of wire rope(excluded filler wire)”

  • PDF

The Mechanical Appearances and Microscopic Tissue Reactions of the Suture Materials in vivo (생체내 이식된 흡수성 봉합사들의 물리적 성질 변화와 조직 소견에 관한 연구)

  • 김남중;김명철
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.184-194
    • /
    • 1996
  • A comparative study of three absorbable suture materials of chromic catgut, Dexon II (a polyglycolic acid suture with a polycaprolate coating system) and Coated Vicryl (a polyglactin 910 suture with a glycolide-lactide-calcium stearate coating system) was undertaken in terms of tensile strength, breaking elongation, appearances of the suture materials in the subcutaneous layer of rats and of tissue reaction in the intramuscular layer of rats. The initial tensile strength of chromic catgut and the tensile strength after 21 days were about 1.55 kg and 0.19 kg, respectively. Those of Dexon II were about 2.01 kg and 0. 20 kg, respectively. Those of Coated Vicryl were about 2.39 kg and 0.48 kg, respectively. Coated Vicryl showed the highest tensile strength among the three materials during the whole period. On the other hand, Dexon II showed the highest breaking elongation among the three materials during the first week. But the breaking elongation of Dexon II rapidly continuously decreased during the whole period. The appearances of the suture materials in the subcutaneous layer of rats showed that chromic catgut was the fastest among the three materials, whereas it formed comparatively much connective tissue. The intramuscular absorption rate and tissue reaction of Dexon II were similar to those of Coated Vicryl. The intramuscular absorption rate of these was fairly late when compared with chromic catgut. And the tissue reaction appearance of these showed the formation of a granuloma with foreign body giant cells, macrothages and epitheloid cells by the 28th day in the experimental period.

  • PDF

Seam Strength of Hand Sewing and Machine Sewing according to The Seam Type in Korea Costumes (솔기유형에 따른 손바느질과 재봉질의 봉합강도)

  • Kim, Jeong-Jin;Jang, Jeong-Dae
    • Fashion & Textile Research Journal
    • /
    • v.2 no.2
    • /
    • pp.146-149
    • /
    • 2000
  • This study has been investigated the comparison of the seam strength of hand sewing with machine sewing using two kinds of sewing thread. On machine sewing, thread is used for sale, on hand sewing, thread is used for every fabric weft yarn. Breaking strength, efficiency and breaking mode of seams were examined under various sewing conditions using three kinds of fabric and three kinds of stitch type. The results obtained are as follows: The seam strength is not affected by sewing mechanism, but affected by a breaking mode : The type of slipped mode has a higher seam strength of hand sewing than that of machine sewing. When fabrics and threads were broken by a higher seam strength of machine sewing than that of hand sewing. Fabrics having low density using plain seam slipped more easily, so seam strength was greatly lesser. Fabrics having higher density had higher to seam strength. We should choose appropriate seams based on production, economy and aesthetics.

  • PDF

The Durability of Polybutylene Succinate Monofilament for Fishing Net Twines by Outdoor Exposure Test (옥외 노출시험에 의한 PBS 단일섬유 망사의 내구성 변화)

  • Park, Seong-Wook;Kim, Seong-Hun;Lim, Ji-Hyun;Choi, Hea-Sun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.4
    • /
    • pp.766-774
    • /
    • 2013
  • Biodegradable polybutylene succinate(PBS) is a kind of environmentally friendly plastics for fisheries, because it can mitigate the ghost fishing problem caused by gill-net and trap fisheries. To evaluate durability of PBS monofilament, each of different diameter 3 types of monofilaments were spun and exposed to 56 month outdoor and then their gravity, modification of surface, breaking strength, and elongation were analysed. The gravity of PBS monofilament was estimated to be approximately 1.24 when spinning ratio from 4.8 to 6.1. PBS monofilaments did not show any crack after 56 month exposed to outdoor and load-elastic elongation curve was showed sigmoid type. Decreasing ratio of elongation was appeared in the thinnest monofilament 0.2mm diameter and breaking strength was in the thickest monofilament 0.4mm diameter. Breaking strength and elongation at break were decreased rapidly after 48 month exposed to outdoor. Breaking strength reduced linearly after 48 month exposure, while no such linear relationship was found in the case of elongation at break. In results, it was investigated that the durability of PBS monofilament nets for gillnet and trap were 24, 50 month when keep to land, respectively.

Study on the Novel Materials Containing Nanoparticles and Isocyanate Group for Strength Improvement of Hydrogel Ophthalmic Lens

  • Lee, Min-Jae;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.11 no.2
    • /
    • pp.113-120
    • /
    • 2018
  • This study was planned to prepare the high strength hydrogel ophthalmic lens containing isocyanate group and nanoparticles. HDI with carbon nanoparticles were used as additives for the basic combination of HEMA, MA and MMA, and the materials were copolymerized with EGDMA as the cross-linking agent and AIBN as the initiator. The mixture was heated at $100^{\circ}C$ for an hour to produce the high performance hydrogel ophthalmic lens by cast mold method. Measurement of the physical characteristics of the produced material showed that the refractive index was in the range of 1.4027~1.4600, water content 25.21~44.01%, contact angle $54.18{\sim}72.94^{\circ}$, visible light transmittance 53.03~92.09%, and tensile strength 0.1024~0.2359 kgf and breaking strength was 0.0872~0.2825 kgf. The results showed an increase of refractive index while the decrease in water content. And also, the breaking strength was highest when the addition ratio of HDI was 5%(wt). As a result of the absorbance measurement, no significant difference was observed in all the samples, so it can be judged that the stabilization of nanoparticles in the polymer was maintained.

The Effect of Administration of Steroid on the Wound Breaking Tensile Strength in Rats (백서에서 스테로이드 투여가 창상 파열장력에 미치는 영향)

  • Kwon, Nam Ho;Kim, Han Koo;Kim, Woo Seob;Bae, Tae Hui
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.538-542
    • /
    • 2009
  • Purpose: The successful wound healing means the scarless wound with adequate strength. It has been shown in vivo and in vitro that steroid retard the collagen synthesis. We studied the effect of steroid on the wound breaking strength in rats. Methods: 40 Sprague - Dawley rats were evenly assigned to two groups. One group was served as control, the other group was experimental. We made dorsal midline incision and closed the wound. In the experimental group, we medicated methylprednisolone (0.15 mg/g/day) for 1 week. Then, we compared the differences of the breaking strength and microscopic histology between control and experimental group at 2, 4, 6 and 8 week. Results: Up to 4 week, the breaking strength of the experimental group was markedly decreased than that of control group, while at 6 week the strength of experimental group attained to that of control group nearly. In histologic findings, control group demonstrated dense organization of collagen to experimental group at 4th week. Conclusion: In this experiment, steroid significantly inhibited the strength gain in wound at early period of the wound healing process. When using steroid after the surgery or the wound formation, it is desirable to administrate carefully and need thorough wound management to prevent delayed wound healing.

Effects of Ketoprofen on Wound Healing in Rats (Ketoprofen이 랫트의 창상치유에 미치는 영향)

  • 구자동;배춘식;장경진
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.193-198
    • /
    • 1999
  • Ketoprofen has been used as nonsteroidal anti-inflammatory (NSAI) agent for analgesia in surgical patients and increasing numbers of surgical patients are chronically take some forms of NSAI drugs. The purpose of this study was to investigate the therapeutic effects of ketoprofen on the healing of a closed linear surgical wound and on the contraction of an opened surgical wound in rats. The experimental groups were divided into two groups and ten rats were allocated in each group. In ketoprofen-treated group, the rats were given 2.5 mg/mg/day of ketoprofen by s.c. for ten days. In control group, the rats were given 1ml of benzyl alcohol and distilled water by s.c. for ten days. After time period, all rats were sacrificed, and the breaking strength and the collagen concentrations, at the wound site, were measured. In ketoprofen-treated group, the mean breaking strength and the mean collagen concentration were significantly decreased when compared with those of controls. The ketoprofen-treated group had shown a mean rate of wound contraction less than that of the control, although not statistically significant. These results suggested that ketoprofen impaired wound healing.

  • PDF

A Study on the Mechanical Change of Emulsion-Treated Hair by Color

  • Ko, Hee-Ja;Park, Jang-Soon
    • Textile Coloration and Finishing
    • /
    • v.34 no.2
    • /
    • pp.127-133
    • /
    • 2022
  • With the increasing interest in the expression of individuality and appearance of modern people, it is time to conduct research and development of novel hair coloring from various angles. Therefore, taking into account the order of discoloration of hair pigments, we selected a creative and novel emulsion as a novel material for hair coloring, rather than a cosmetic material such as hot water extract using natural products dealt with in previous studies, commercially available hair manicure, and oxidation hair dye for hair. Thus, the change in tensile strength and elongation of hair samples by color was studied. As a result of the study, hair with green emulsion paint had a significantly higher maximum load, maximum stress, maximum elongation and breaking load, breaking stress, breaking elongation values are shown. Maximum in terms of modulus, green emulsion applied hair and the control group were higher in the 0-15s strain and 15-145s sections, respectively, and the tangential modulus value was much higher in the control group than the experimental group hairs in all the 0-145s sections. This study, which analyzes the dynamic changes of hair samples that extend the daily color gamut, will greatly contribute to the development of innovative hair coloring materials in the research and production of hair beauty works, and it is judged that it will also contribute to the development of the beauty industry.