발전기 고정자 권선의 정전용량 측정을 통한 흡습 진단 방법에 관한 연구 (A Study on the Water Absorption Diagnosis Method through Capacitance Measurement for Generator Stator Windings)

  • 김희수;배용채;기창두
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.50-57
    • /
    • 2006
  • The water leak in water-cooled generator stator windings can generate the serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them for the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. The developed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

친환경 배전급 전력케이블용 절연재료의 전기적 특성에 관한 연구 (I) (A Study on Electrical Properties of Insulating Materials for Eco-friendly Distribution Power Cables (I))

  • 이준호;김철호;조영철;이문석
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.551-556
    • /
    • 2017
  • The cross-linked polyethylene(XLPE) has been most widely used for the power cable insulating layer because of its outstanding properties such as electrical and mechanical properties. However, XLPE is unrecyclable when disposed after replacement and demolishing because it becomes thermosetting through cross-linked process. Recently, because of growing social awareness of recycling and eco-friendly, there is growing need for the development of recyclable insulating materials that can replace XLPE. Therefore, the purpose of this study is to compare the electrical properties of XLPE and recyclable thermoplastic insulating materials. To this end, we compared and analyzed the electrical properties of XLPE and group N2 through AC breakdown test, accelerated water treeing test and accelerated life test(ALT).

22.9kV 트리억제형 전력케이블의 성능평가 (Efficiency appraisal of 22.9kV tree retardant power cable)

  • 김위영;윤대혁;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.179-182
    • /
    • 2002
  • XLPE compound have used for insulation of 22.9(kV) power cable. But tree retardant power cable has developed and is going to br used commonly. TR XLPE compound retard production and growth of water tree. In this paper, tensile strength, elongation at break, degree of crosslinking, lightning impulse test, AC breakdown test, cyclic aging for 14days and accelerated water treeing test of TR XLPE insulated power cable were examined according to the KEPCO buying spec. & AEIC CS 5-94 standards. before and after As the result, tensile strength, elongation at break and degree of crosslinking test results of TR XLPE insulation were higher than requirement values. After accelerated water treeing test for 120 days, 240 days and 360 days, AC breakdown voltages were not decreased for accelerated water treeing aging duration

  • PDF

자동차 점화코일용 절연유의 전기적 특성 (Electrical properties of insulating oils for automobile ignition coil)

  • 신종열;홍진웅
    • 한국자동차공학회논문집
    • /
    • 제7권5호
    • /
    • pp.172-177
    • /
    • 1999
  • In this paper, the physical and electrical properties of the synthetic fluids No. 2 class Ⅶ used the insulating oils for automobile ignition coil are studied. Also, benzotriazole(BTA) as the streaming electrification suppressant additive is added to the oil, and the change of physical and electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown and the changes of conductivity by measuring volume resistivity are analyzed. It is considered that the effective content of BTA as charge suppressant additive is about 10[ppm] from the results of AC breakdown and volume resistivity test.

  • PDF

변압기유의 불순물에 따른 유동대전 영향 (The Effect on the Streaming Electrification of Insulating Oils with Impurity)

  • 이용우;이광석;송병기;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.329-333
    • /
    • 1996
  • In this Paper, the streaming electrification of transformer oils generated at the interface of transformer oils and the AC breakdown with impurity is studied. The electrification current is measured by the electrometer connected the faraday cage. And a oil velocity is maintained equally. In case of the AC breakdown test, the temperature are 30[$^{\circ}C$], 50[$^{\circ}C$], 80[$^{\circ}C$] and 90[$^{\circ}C$], repetitively. As a result of breakdown experiment, the dielectric breakdown strength is decreased in low temperature region and is increased in high temperature region according to increase of contained sodium. In case of streaming electrification experiment, the streaming current is more increased with the specimen contained sodium than the original specimen.

  • PDF

세라믹 코팅 Al 부스바의 전기적 특성 연구 (Study on Electrical Properties of Ceramic Coated Al Bus Bar)

  • 백승명;곽민환;곽동순
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1647-1650
    • /
    • 2017
  • Bus bars are used in place of cables because they can carry more electrical energy with the same volume of conductors. This paper deals with the electrical properties of ceramic coating material for busbars. A ceramic coated samples were prepared for the electrical properties test. There are two types of samples. One is a sample without degradation, and the other is a sample degraded for 30 days. Four electrical properties tests were carried out in accordance with domestic standards. Four electrical characteristics tests are AC dielectric breakdown, V-t, lighting impulse dielectric breakdown, and discharge arc. Both samples showed excellent electrical properties, and the ceramic coating material is very good insulating materials for bus bar.

A Study on the Insulation Characteristics for Stator Windings of IGBT PWM Inverter-Fed Induction Motors

  • Hwang, Don-Ha;Kang, Dong-Sik;Kim, Yong-Joo;Lim, Tae-Hoon;Bae Sung-Woo;Kim Dong-Hee;Ro Chae-Gyun
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.159-166
    • /
    • 2003
  • The winding insulation of low-voltage induction motors in adjustable-speed drive system with voltage-fed Inverters is substantially stressed due to the uneven voltage distribution and excessive voltage stress (dv/dt), which result in the premature insulation breakdown In this paper, the detailed insulation test results of 26 low-voltage induction motors are presented. Six different types of insulation techniques are applied to 26 motors. The insulation characteristics are analyzed with partial discharge, discharge inception voltage, AC current, and dissipation factor tests Also, insulation breakdown tests by high voltage pulses are performed, and the corresponding breakdown voltages obtained.

회전기계의 고장안전진단 사례연구 (A Case Study of the Breakdown Evaluation to the Rotary Machine)

  • 홍태용;박수홍
    • 한국전자통신학회논문지
    • /
    • 제10권2호
    • /
    • pp.189-194
    • /
    • 2015
  • 본 연구에서는 회전기계에서 발생할 수 있는 고장에 대한 안전진단에 대한 사례연구이다. 각각의 회전기계에 대하여 진동분석을 통한 고장발생유무를 각종의 측정 데이터를 이용하여 분석하여 향후에 발생할 수 있는 고장에 대한 안전진단에 대한 방법을 연구하였다. 본 연구에서 제안한 상태 감시 및 진단 방법을 적용한 결과, 회전기계의 추후 고장을 예측할 수 있었다.

계면이 존재하는 PET flim의 절연파괴와 전기전도특성에 관한 연구 (A Study on the Property of the Breakdown Strength and the Electrical Conduction of the PET Flim being Interface)

  • 강무성;오재형;박대희;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.221-223
    • /
    • 1996
  • The test on the breakdown strength and the electrical conduction property about the PET flim have been done when the interface exist and do not exist between the PET flim. The PET flim that does not exist the interface uniformly maintained the breakdown strength as the temperature increase. But, the breakdown strength of the PET flim inserted carbon black flim decreased as the temperature increase. The initial current of the PET flim inserted carbon black flim was higher than the PET flim and the uniformly distributed between 2.2E-9 and 2.5E-9 above 5kV/mm.

  • PDF

온도변화에 따른 $SF_6$ 가스의 절연특성 (Characteristics of Dielectries in $SF_6$ Accoding to a change in Temperature)

  • 이복희;김회구;박건훈;이규선;김동성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1436-1437
    • /
    • 2007
  • This paper presents the experimental results of the dielectric characteristics with temperature changes under highly non-uniform electric field in $SF_6$ gas. The impulse preliminary breakdown developments were investigated by the measurement of predischarge current and breakdown voltage. As a result, the first stremer corona is initiated at the tip of needle electrode, and bridges the test gap. Also the first stremer corona onset and breakdown voltages the negative polarity was much higher than that in the positive polarity in same temperature. In addition, the varition of temperature have a little effect on the positive polarity. On the other hand, in some cases negative polarity corona onset and breakdown voltages increased with increasing a high temperature.

  • PDF