• Title/Summary/Keyword: Breakdown pressure

Search Result 312, Processing Time 0.026 seconds

AC Breakdown Characteristics in Ar/$N_2$ and Kr/$N_2$ Gas Mixtures (Ar/$N_2$ 및 Kr/$N_2$ 혼합 가스의 교류절연파괴 특성)

  • Lee, Sang-Woo;Kim, Lee-Kook;Kim, In-Sik;Cu, Kyung-Chul;Lee, Dong-In;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1744-1746
    • /
    • 2001
  • In this paper, we investigated the breakdown characteristics of Ar, Kr and $N_2$ gas in pure states with pressure range of 58.8-137.3[kPa] under uniform and non-uniform fields, and the measured values are compared with those in Ar/$N_2$ gas mixtures. From these results, the breakdown voltages of $N_2$ gas in uniform field were increased about 4.8 and 4.4 times than those of Ar and Kr gas, respectively. Breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of $N_2$ gas. Breakdown voltages of Ar(70%)/$N_2$(30%) gas mixtures in the pressure of 101.3[kPa] (gap length : 3[mm]) were increased 1.9 times than those of pure Ar gas.

  • PDF

Dielectric Insulation Properties of Double Pancake Coil Type HTS Transformer (Double Pancake Coil형 고온초전도 변압기의 전기적 절연 특성)

  • 백승명;정종만;이현수;한철수;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.151-156
    • /
    • 2003
  • High temperature superconductor can only be applied against an engineering specofication that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and AC breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. The Breakdown of LN$_2$ is dominated electrode shape and distance. The influence of pressure on breakdown voltage is discussed with th different electrode. For the electrical insulation design of turn-to-turn insulation for the HTS transformer, we tested breakdown strength of insulation sheet under varying pressure. And we investigated surface flashover properties of LN$_2$ and complex conition of cryogenic gaseous nitrogen(CGN$_2$) obove a LN$_2$ surface. The surface voltage of GFRP was measured as a function of thickness and electrode distance in LN$_2$ and complex condition of CGN$_2$ above a LN$_2$ surface. this research presented information of electrical insulation design for double pancake coil(DPC) type HTS transformer.

AC Breakdown Voltage Simulation of SF6/N2 Mixture in Non-Uniform Field and Its Comparison with Experimental Values (불평등 전계에서 SF6/N2 혼합가스의 AC 절연파괴전압 시뮬레이션 및 실험값와의 비교)

  • Lee, Byung-Taek;Hwang, Cheong-Ho;Lee, Tae-Ho;Huh, Chang-Su;Chang, Yong-Moo;Lee, Ki-Taek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1416-1422
    • /
    • 2010
  • $SF_6$ is the most commonly used insulating gas in electrical systems. But In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. At present study the breakdown characteristics of $SF_6/N_2$ mixtures in Non-uniform field was performed. In this paper, The simulation value are compared with experiment values. Streamer breakdown criterion was used for predicting breakdown voltage. For accurate simulation this simulation apply utilization factor using CST(computer simulation technology) EM $studio^{tm}$ program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. The pressure range of gas mixtures was 0.4 MPa to 0.7 MPa. The rod-plane was used and mixture ratio is $SF_6$ 20% : $N_2$ 80%. The gap lengths are 10mm to 70mm. As the pressure increase, this simulation value does not correspond to the experiment value. So this simulation need surface roughness factor. As a result of applying surface roughness factor this simulation decrease a relative error (|experiment value - simulation value| /simulation value).

Characteristics of Laser-Induced Breakdown Spectroscopy (LIBS) at Space Environment for Space Resources Exploration (우주 자원 탐사를 위한 레이저 유도 플라즈마 분광분석법의 우주 환경에서의 특성 분석)

  • Choi, Soo-Jin;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.4
    • /
    • pp.346-353
    • /
    • 2012
  • The Laser-Induced Breakdown Spectroscopy (LIBS) has great advantages as an analytical technique, namely real-time analysis without sample preparation, ideal for mobile chemical sensor for space exploration. The LIBS plasma characteristics are strongly dependent on the surrounding pressure. In this study, seven types of target (C, Ti, Ni, Cu, Sn, Al, Zn) were investigated for their elemental lifetime. The target was located in vacuum chamber which has the pressure range of 760 to $10^{-5}$ torr. As the pressure is decreased, the elemental lifetimes of carbon and titanium declined, while all other targets showed increased lifetimes until reaching 1 torr and declined with continued pressure decrease. The boiling point and electronegativity amongst the physicochemical properties of the samples are used to explain this peculiarity.

Breakdown Voltage and Partial Discharge Characteristics at the Simulated Interface in a Prefabricated Joint for Ultra High Voltage Cable (초고압용 조립형 접속함 모의계면에서 압력에 따른 절연파괴 및 부분방전 특성)

  • Kim, J.N.;Baek, J.H.;Shin, D.S.;Lee, C.Y.;Kim, C.S.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1099-1101
    • /
    • 1999
  • PJB(Prefabricated Joint Box) is consisted of three major components ; an epoxy unit, a stress relief cone and a spring unit. The insulation structure of PJB is maintained by the interfacial pressure, and the dielectric performance at the interface depends on the interfacial pressure which is regarded as the most important factor for preventing breakdown failure. This experiment was performed to investigate breakdown voltage characteristic and partial discharge patterns under the controlled pressure conditions at the simulated interface. Finally, this paper presents the optimal pressure conditions at the interface by analyasing the PD patterns.

  • PDF

Electrical Breakdown and Flashover Characteristics of Gaseous Helium at Cryogenic Temperature (극저온 헬륨가스의 절연파괴 및 연면방전 특성)

  • Kwag, Dong-Soon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.38-42
    • /
    • 2012
  • Fixtures such as bushings in terminations of high temperature superconducting(HTS) power cable systems are subjected to high voltages, which have to transition from ambient to cryogenic temperatures. As such it is imperative to ensure the integrity of the dielectrics under all operating conditions, including thermal aspects brought about by the passage of current. Gaseous helium(GHe) at high pressure is regarded as a potential coolant for superconducting cables. The dielectric aspects of cryogenic helium gas are both complex and demanding. In this experimental study we looked at the interface between a smooth epoxy surface and high pressure helium gas in a homogeneous electric field. The alternating current(AC) flashover voltages of epoxy samples are presented. The results have been analyzed by using Weibull statistics. In addition to the behavior of the epoxy in gaseous helium as a function of pressure and temperature we also present data of the characteristics of the epoxy in mineral oil and in liquid nitrogen($LN_2$). The breakdown characteristics of a uniform field gap in gaseous helium as a function of pressure and temperature under AC, direct current(DC) and lightning impulse voltages are also given. Electric field calculations have been made for one of the experimental geometries in an attempt to explain some of the anomalies in the experimental results.

AC Electrical Breakdown Characteristics of an Epoxy/Mica Composite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.200-203
    • /
    • 2012
  • Epoxy/mica composite was synthesized, in order to use it as an impregnation resin in a vacuum pressure impregnation (VPI) process, for manufacturing a high voltage rotary machine. The average particle size of the mica was 5~7 ${\mu}m$ and its content was 0, 20, 30 and 40 wt%. A plasticizer or a low molecular aliphatic epoxy was also used, to decrease the viscosity of the composite. The AC electrical breakdown strength was estimated in sphere-to-sphere electrodes, and the electrical breakdown data were estimated by Weibull statistical analysis. The electrical breakdown strength became higher with the addition of mica; and that of the system with 20 wt% mica was highest. The electrical breakdown strength of the system with an aliphatic epoxy was higher than that of the system with a, plasticizer.

A Study on the Dielectric Strength in Section of Winding in SF6 Gas Transformer ($SF_6$ 가스절연변압기에서 권선의 섹션에 대한 절연내력 연구)

  • Heo, U-Haeng;Ha, Yeong-Sik;Hong, Jeong-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.152-158
    • /
    • 2000
  • This paper deal with the experimental discussion about the impulse and AC dielectric strength of SF6 gas insulated transformer. Test sample is measured the dielectric breakdown voltage about modeling of the first and second section which is the weakest for surge voltage. The AC breakdown voltage is appeared 1.4 times than impulse breakdown voltage, so we can estimate that the impulse breakdown voltage is severe to AC breakdown voltage, and when the impulse is applied, in case of lmm tapping with Nomex paper, the characteristics of dielectric breakdown voltage is same to that in oil immersed transformer when SF6 gas pressure is 2.2kg/$cm^2$G.

  • PDF

AC Breakdown Characteristics of Pure Ar, $N_2$ Gas and Ar/$N_2$ Gas Mixutres under Uniform and Non-Uniform Fields (평등 및 불평등 전계하에서 순수 Ar, $N_2$가스와 Ar/$N_2$혼합 가스의 교류절연파괴 특성)

  • 이상우;김인식;이동인;이광식;김이국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, the AC breakdown characteristics of pure Ar and $N_2$gas with gas pressure range of 58.8~137.3[kPa] under uniform and non-uniform fields were investigated, and the measured values were compared with those in Ar/$N_2$gas mixtures with pressure varying. Summarizing the experimental results, the breakdown voltages of pure $N_2$gas, under uniform and non-uniform fields, were increased about 4.8 and 1.1 times than those of pure Ar gas, and the AC breakdown voltage increased with the pressure increasing. The breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of $N_2$gas. In case of Ar(85%)/$N_2$(15%) and Ar(70%)/$N_2$(30%) gas mixtures comparing to the pure Ar gas, the breakdown voltages under uniform field were increased about 1.5 and 2.1 times, and under non-uniform field were increased about 1.1 and 1.3 times at the pressure of 101.3[kPa]. Also, corona inception voltage of Ar(70%)/$N_2$(30%) gas mixtures under non-uniform field were increased about 1.5 times than those of pure Ar gas.

  • PDF

Dielectric Characteristics of $SF_{6}$ Gas Stressed by VFTO in Inhomogeneous Field (불평등전계중에서 과도과전압에 대한 $SF_{6}$가스의 절연특성)

  • 이복희;이창준;길경석;안창환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.306-309
    • /
    • 1995
  • This paper describes the dielectric characteristics of $SF_{6}$ gas in a non-uniform electric field under overvoltages. The breakdown voltage-time characteristics and the breakdown voltage-gas pressure characteristics are measured within a gas pressure range extending from 0.1 to 0.5 [Mpa] for the plane electrode system with a needle-shaped protrusion. The curvature radius of the needle protrusion is 0.5[mm]. Also, the growth process of the predischarge are simultaneously observed. As a result, it is found that the breakdown mechanism and predischarge phenomena are closely associated with the polarity and waveforms of the testing voltage.

  • PDF