• Title/Summary/Keyword: Breakdown pressure

Search Result 312, Processing Time 0.025 seconds

Prebreakdown Phenomena of $SF_{6}$ Gas in a Non-uniform Field Disturbed by a Metallic Protrusion

  • Lee, Kyoung-Ok;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.137-141
    • /
    • 1996
  • This paper deals with the prebreakdown phenomena of $SF_{6}$ gap stressed by non-oscillating and oscillating impulse voltages in a strong inhomogeneous field disturbed by a fred needle shaped-protrusion on the earth-side electrode. The breakdown voltage-time characteristics were measured for both positive and negative polarities and over the gas pressure range of 0.1∼0.5 MPa, and the temporal developments of the 77breakdown were observed by a shunt of 50 n. The dependence of the leader stopping time on the gas pressure were obtained. The local field enhancement due to the space charges, which is produced by the streamer corona, has influence with the electrical breakdown of the test gap. The test streamer corona is oxy a necessary condition for the electrical breakdown and the subsequent ionization activities launch the leader at the local field region.

  • PDF

Accurate Prediction Method of Breakdown Voltage in Air at Atmospheric Pressure

  • Kim, Nam-Kyung;Lee, Se-Hee;Georghiou, G.E.;Kim, Dong-Wook;Kim, Dong-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.97-102
    • /
    • 2012
  • To predict accurately the breakdown voltage in air at atmospheric pressure, a fully coupled finite element analysis combining the hydrodynamic diffusion-drift equations with Poisson's equation is proposed in the current paper. As three kinds of charged transport particles are nonlinearly coupled with spatial electric fields, the equations should be solved by an iterative numerical scheme, in which secondary effects, such as photoemission and photoionization, are considered. The proposed method has been successfully applied to evaluate the breakdown voltage in circular parallel-plane electrodes. Its validity has been proved through the comparison of the predicted and experimental results. The effects of numerical conditions of the initial charge, photoemission, and background ionization on the discharge phenomena are quantitatively assessed through Taguchi's design of experiment method.

Breakdown Characteristics of $SF_6$ Gas under Non-Uniform Field (불평등 전계중의 $SF_6$가스 절연파괴특성)

  • Seo, Kil-Soo;Moon, In-Wook;Kim, Ik-Soo;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1326-1329
    • /
    • 1995
  • An influences of gap clearance, pressure and applied voltage shape on breakdown characteristics are investigated by using a rod-to-plane electrode in $SF_6$ gas. In case of D.C and A.C, a corona stabilization effect increases the breakdown voltage remarkably for lower pressure than 0.2MPa, whereas incase of negative D.C this effect exists independently of gas pressure. This suggests that an insulation optimization in a pratical apparatus is needed to prevent a corona appearance through the removal of local field enhancement.

  • PDF

A study on the electrical characteristics of the fluorocarbon (Fluorocarbon의 전기적 특성연구)

  • 허창수;조한구
    • Electrical & Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.217-223
    • /
    • 1995
  • In this paper, we investigated physical properties and electrical characteristics of the fluorocarbon that used as coolants for large power gas-insulated transformer. Volume resistivity of the fluorocarbon was .rho.=1.87*10$^{15}$ [.ohm.cm] at 1 atm, 27.deg. C. Dielectric constant was 1.86 and decreases as temperature increase. The breakdown voltage at 1 atm was higher than that of transformer oil. The breakdown voltage of fluorocarbon vapor was about 18kV when pressure in a test chamber increases over lkg/cm$^{2}$. When fluorocarbon was mixed with SF$_{6}$ gas, breakdown voltage of the mixed was higher than that of fluorocarbon. Then fluorocarbon leads to increase over 4kg/cm$^{2}$ in pressure as temperature increase. Therefore, when a gas-insulated transformer is manufactured, the design must be taken into consideration a high-pressure.

  • PDF

The Effect of Surface Roughness on Breakdown in Air (공기중 절연파괴에 있어서 전극표면의 요철에 의한 영향)

  • 오철한;김미태
    • 전기의세계
    • /
    • v.28 no.11
    • /
    • pp.33-36
    • /
    • 1979
  • In a uniform field, when an electrode with a hemispherical protrusion is set in atmosphere, by applying the streamer breakdown criterion and the surface roughness factor, the effect of field distortion due to electrode surface roughness on breakdown is investigated theoretically. A quantitative relation between the threshold of breakdown and the air pressure times the heigh of protrusion is derived by the aid of a computor and the results are compared with that of SF$_{6}$./.

  • PDF

Effects of walking speed on peak plantar pressure in healthy subjects (정상인에서 보행 속도가 발바닥의 최대압력분포에 미치는 영향)

  • Ha, Mi-Sook;Nam, Kun-Woo
    • Journal of Korean Physical Therapy Science
    • /
    • v.22 no.2
    • /
    • pp.43-47
    • /
    • 2015
  • Background : Many factors affect foot and ankle biomechanics during walking, including gait speed and anthropometric characteristics. This study examined the effect of walking speed on peak plantar pressure during the walking. Method : Thirty two normal healthy subjects (16 men, 16 women) were recruited. Peak plantar pressure was investigated using pressure distribution platforms (Pedoscan system) under the hallux heads of the first, second, and third metatarsal bones, and heel. Result : The results also suggest that slow walking speeds may decrease forefoot peak plantar pressure in patients with peripheral neuropathy who have a high risk of skin breakdown under the forefoot(p<0.05). Conclusion : The results also suggest that slow walking speeds may decrease forefoot peak plantar pressure in patients with restricted low extremity range of motion who have a high risk of skin breakdown under the forefoot.

  • PDF

AC Breakdown Characteristics of $Ar/N_2 and Kr/N_2$Gas Mixtures ($Ar/N_2 및 Kr/N_2$혼합가스의 교류절연파괴 특성)

  • Lee, Sang-Woo;Kim, In-Sik;Lee, Dong-In;Lee, Kwang-Sik;Kim, Lee-Kook
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.599-606
    • /
    • 2001
  • In this paper, the ac breakdown characteristics of pure Ar, Kr and $N_2$ gas with gas pressure range of 58.8-137.3[kPa] under uniform and non-uniform fields were investigated, and the measured values were compared with those In Ar/$N_2$ and Kr/$N_2$ gas mixtures with pressure varying. Summarizing the experimental results, the breakdown voltages of Pure $N_2$gas, under uniform and non-uniform fields, were increased about 4.8 and 1.1 times than those of pure Ar gas, and about 4.4 and 1.2 times than those of pure Kr gas, and the ac breakdown voltage increased with the pressure increasing. The breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of Pure $N_2$ gas. In case of Ar(85%)/$N_2$ (15%) and Ar(70%)/$N_2$ (30%) gas mixtures comparing to the pure Ar gas, the breakdown voltages under uniform field were increased about 1.8 and 2.2 times, and under non-uniform field were increased about 1.1 and 1.3 times at the pressure of 101.3[kPa]. Also, in case of Kr(85%)/$N_2$ (15%) and Kr(70%)/$N_2$ (30%) gas mixtures comparing to the pure Kr gas, the breakdown voltages under uniform field were increased about 1.7 and 2.0 times, and under non-uniform field were increased about 1.0 and 1.2 times. Corona inception voltage of Kr(70%)/$N_2$(30%) gas mixtures under non-uniform fields were increased about 1.28 times than those of Ar(70%)/$N_2$ (30%) gas mixtures. In case of practical incandescent lamps, luminous and lifetime of Kr(70%)/$N_2$ (30%) gas mixtures were increased about 1.15 and 1.21 times than those of Ar(70%)/$N_2$ (30%) gas mixtures.

  • PDF

Breakdown characteristics of EPDM/XLPE laminate (XLPE /EPDM laminate의 절연파괴 특성)

  • Nam, Jin-Ho;Suh, Kwang-S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1596-1598
    • /
    • 1999
  • In order to determine what influences the interfacial breakdown between two internal dielectric surfaces. We studied the interfacial breakdown phenomena at several interfacial conditions. With the increase of interfacial pressure, at first breakdown strength in interfaces was increased, and then saturated. Breakdown strength in interface pasted with silicone oil was higher than that with silicone grease. As a function of heat treatment time in a vacuum oven interfacial breakdown strength was increased much in XLPE/EPDM laminates pasted with silicone grease but increased a little in that with silicone oil. As an increase of curing agent in silicone oil and grease, breakdown strength in interfaces was increased and then saturated.

  • PDF

Dynamic Electrical Breakdown Characteristics of Cryogenic Liquid (극저온 액체의 동적 절연파괴 특성)

  • 김상현;김현희;김영석;정종만;정순용
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.321-326
    • /
    • 1998
  • Electrical breakdown characteristics of liquid nitrogen($LN_2$) taking into consideration for application of high $T_c$ superconductor is very important. Also $LN_2$ will be used as both coolant and insulator in superconducting generator. In this paper, we investigated ac breakdown characteristics of cryogenic nitrogen gas above a $LN_2$ for rod-to plane electrode configuration. As result the breakdown mechanism of $LN_2$is dependence on bubble effect. And breakdown voltage is a ratio on bubble s size but electrodes arrangement is to make no difference. The breakdown voltage decreases slightly with increasing flow velocity, it again decreases abruptly with increasing flow velocity. These results were interpreted as the within pressure of rod electrode and Maxwell force.

  • PDF

A Study on the AC Interfacial Breakdown Properties of the Interface between Epoxy/EPDM with Variation of the Spread Oil (도포된 오일의 변화에 따른 Epoxy/EPDM 계면의 교류 절연파괴 특성에 관한 연구)

  • Bae, Deok-Gwon;Jeong, Il-Hyeong;O, Jae-Han;Park, U-Hyeon;Lee, Gi-Sik;Kim, Chung-Hyeok;Lee, Jun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.8
    • /
    • pp.445-450
    • /
    • 2000
  • Many successful developments and microscopic studies have been made on the high quality insulating materials. However, a little attention have given to the macroscopic interface in HV(High Voltage) insulating systems. In this study, AC interfacial breakdown strength and V-t characteristic of the interface between Epoxy/EPDM(ethylene propylene diene terpolymer) are investigated. Electrode system is designed to reduce the charges from electrodes and to have the tangential potentials along the interface between Epoxy/EPDM by FEM(finite elements method). The AC breakdown strength is observed when HV is given to the interface. It is shown that AC interfacial breakdown strength is improved by increasing interfacial pressure and oiling. In particular, it was saturated at certain interfacial pressure level. V-t characteristic is able to extend to the life time of the interface between Epoxy/EPDM. Oiling also plays a good roll in prolongation of the life time.

  • PDF