• Title/Summary/Keyword: Breakdown point

Search Result 167, Processing Time 0.023 seconds

Study of Discharge in Point-Plane Air Interval Using Fuzzy Logic

  • Bourek, Yacine;Mokhnache, Leila;Nait Said, Nacereddine;Kattan, Rafik
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.410-417
    • /
    • 2009
  • The objective of this paper is to study the discharge phenomenon for a point-plane air interval using an original fuzzy logic system. Firstly, a physical model based on streamer theory with consideration of the space charge fields due to electrons and positive ions is proposed. To test this model we have calculated the breakdown threshold voltage for a point-plane air interval. The same model is used to determine the discharge steps for different configurations as an inference data base. Secondly, using results obtained by the numerical simulation of the previous model, we have introduced the fuzzy logic technique to predict the breakdown threshold voltage of the same configurations used in the numerical model and make estimation on the insulating state of the air interval. From the comparison of obtained results, we can conclude that they are in accordance with the experimental ones obtained for breakdown discharges in different point-plane air gaps collected from the literature. The proposed study using fuzzy logic technique shows a good performance in the analysis of different discharge steps of the air interval.

ROBUST REGRESSION ESTIMATION BASED ON DATA PARTITIONING

  • Lee, Dong-Hee;Park, You-Sung
    • Journal of the Korean Statistical Society
    • /
    • v.36 no.2
    • /
    • pp.299-320
    • /
    • 2007
  • We introduce a high breakdown point estimator referred to as data partitioning robust regression estimator (DPR). Since the DPR is obtained by partitioning observations into a finite number of subsets, it has no computational problem unlike the previous robust regression estimators. Empirical and extensive simulation studies show that the DPR is superior to the previous robust estimators. This is much so in large samples.

Breakdown Characteristic of Transformer Oil Depending on Tip Radius (침전극 곡률 반경에 따른 절연유의 절연파괴 특성)

  • Lee, J.S.;Jeong, S.H.;Lee, H.K.;Lim, K.J.;Kim, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1478-1480
    • /
    • 1997
  • We investigated the breakdown characteristic of mineral oil according to applied voltage and tip radius. In this experiment, electrode system was point-plane geometry. The tip radius of needle was 5, 10, 20 and $25{\mu}m$, respectively. Applied voltage was AC and DC. We measured breakdown voltage for each tip radius with increasing electrode gap, 2mm to 10mm. Under nonuniform electric field, breakdown strength was higher when needle was negative than when needle was positive. Because it is polarity effects due to space charge. And the more sharp tip radius, whether we applied AC or DC, the higher breakdown strength. As tip radius increase, breakdown strength decreases exponentially.

  • PDF

Effective Ionic Wind Generation Utilizing a Cylindrical Corona Discharge Electrode (금속관형 코로나 방전극을 적용한 효과적인 이온풍 발생)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.599-603
    • /
    • 2010
  • A point-mesh type corona system has been well used as a ionic wind blower. However this type corona system suffers from its lower ionic wind generation, because of its lower on-set and breakdown voltages of its very sharp needle point corona electrode. This means that the point corona electrode must act both as an effective ion-generator and a very higher electric field producer in the discharge airgap in order to generate higher ionic wind velocity. In this paper, a cylinder-mesh type discharge system as a ionic wind generator is proposed and investigated. The cylindrical corona electrode can produce many ions from its sharpened edge, and the corona on-set and breakdown voltages are very higher than those of the needle point corona electrode. As a result, this type cylindrical corona electrode might generate a higher ionic wind than the needle point corona electrode.

A Study on a One-step Pairwise GM-estimator in Linear Models

  • Song, Moon-Sup;Kim, Jin-Ho
    • Journal of the Korean Statistical Society
    • /
    • v.26 no.1
    • /
    • pp.1-22
    • /
    • 1997
  • In the linear regression model $y_{i}$ = .alpha. $x_{i}$ $^{T}$ .beta. + .epsilon.$_{i}$ , i = 1,2,...,n, the weighted pairwise absolute deviation (WPAD) estimator was defined by minimizing the dispersion function D (.beta.) = .sum..sum.$_{{i $w_{{ij}}$$\mid$ $r_{j}$ (.beta.) $r_{i}$ (.beta.)$\mid$, where $r_{i}$ (.beta.)'s are residuals and $w_{{ij}}$'s are weights. This estimator can achive bounded total influence with positive breakdown by choice of weights $w_{{ij}}$. In this paper, we consider a more general type of dispersion function than that of D(.beta.) and propose a pairwise GM-estimator based on the dispersion function. Under some regularity conditions, the proposed estimator has a bounded influence function, a high breakdown point, and asymptotically a normal distribution. Results of a small-sample Monte Carlo study are also presented. presented.

  • PDF

V-t Characteristics and Survival Probability of Turn-to-Turn Models for HTS Transformer (고온초전도 변압기를 위한 턴간 모델의 V-t 특성 및 생존 확률)

  • Baek, Seung-Myeong;Cheon, Hyeon-Gweon;Nguyen, Van-Dung;Seok, Bok-Yeol;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.356-362
    • /
    • 2004
  • Using multi wrapped copper by polyimide film for HTS transformer, the breakdown and V-t characteristics of two type models for turn-to-turn, one is point contact model, the other is surface contact model, were investigated under ac and impulse voltage at 77 K. A material that is Polyimide film (Kapton) 0.025 mm thickness is used for multi wrapping of the electrode. Statistical analysis of the results using Weibull distribution to examine the wrapping number effects on V-t characteristics under at voltage as well as breakdown voltage under ac and impulse voltage in $LN_2$ was carried. Also, survival analysis was performed according to the Kaplan-Meier method. The breakdown voltages for surface contact model are lower than that of the point contact model, because the contact area of surface contact model is wider than that of point contact model. At the same time, the shape parameter of the point contact model is a little bit larger than the of the surface contact model. The time to breakdown tn is decreased as the applied voltage is increased, and the lifetime indices slightly are increased as the number of layers is increased. According to the increasing applied voltage and decreasing wrapping number, the survival probability is increased.

  • PDF

A High Breakdown and Efficient GM-Estimator in Linear Models

  • Song, Moon-Sup;Park, Changsoon;Nam, Ho-Soo
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.4
    • /
    • pp.471-487
    • /
    • 1996
  • In this paper we propose an efficient scoring type one-step GM-estimator, which has a bounded influence function and a high break-down point. The main point of the estimator is in the weighting scheme of the GM-estimator. The weight function we used depends on both leverage points and residuals So we construct an estimator which does not downweight good leverage points Unider some regularity conditions, we compute the finite-sample breakdown point and prove asymptotic normality Some simulation results are also presented.

  • PDF

Correlation between Insulation Diagnostic Test and AC Breakdown Test for 3.3 kV Class Induction Motor

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.262-266
    • /
    • 2006
  • The insulation diagnostic test and the AC breakdown test were performed under off-line using the 3.3 kV class induction motor which have been served for 10 years. These tests were conducted in means of nondestructive and destructive test. In this paper, we compared the correlation between the nondestructive and destructive test. Furthermore we setup an experimental condition with moisture and compared the insulation characteristics between moist and dry sample. From the results of the nondestructive and destructive test, it was found that the second AC current, which is the previous step of insulation breakdown, suddenly increased at a point of around 8.5 kV. The insulation breakdown of moist sample occurred at 12-14 kV, which is 4-5 kV lower than dry sample.

Dielectric Breakdown Characteristics of PPLP and GFRP for HTS DC Cable System (고온초전도 DC 케이블 시스템용 PPLP 및 GFRP의 절연 특성)

  • Kim, S.H.;Choi, J.H.;Kim, W.J.;Jang, H.M.;Lee, S.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.3
    • /
    • pp.5-9
    • /
    • 2011
  • DC high-temperature superconducting(HTS) cable system has attracted a great deal of interest from the view point of low loss, dense structure and large capacity. A HTS cable system is made of cable and termination. The insulating materials and insulation technology must be solved for the long life, reliability and compact of cable system. In this paper, we will report on the dielectric breakdown characteristics of insulating materials for HTS cable and termination. The AC, DC and lightning impulse breakdown strength of laminated polypropylene paper(PPLP) and glass fiber reinforced plastic(GFRP) have been measured under nitrogen pressures in the range of 0.l-0.4MPa. PPLP and GFRP are found to have a significantly higher DC breakdown strength. Also, DC surface flashover voltage of negative polarity is slightly higher than that of positive polarity in GFRP.

Effects of Pressure on the Breakdown Characteristics of Cryogenic Liquid and Gaseous Nitrogen (극저온 액체 및 기체 질소의 압력에 따른 절연파괴 특성)

  • 백승명;정종만;김상헌
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.1-4
    • /
    • 2002
  • Electrical properties of liquid nitrogen ($LN_2$) and gaseous nitrogen($GN_2$) have become of great interest again since the discovery of high temperature superconductors . It is very important from a point of superconducting apparatus protection to elucidate breakdown characteristics in $LN_2$ and $GN_2$ at atmospheric and pressurized conditions Therefore. this paper studies the effect of pressure on the breakdown characteristics in $LN_2$ and $GN_2$. Af high voltage is applied to electrode system with uniform and non-unform field in various gap length. And Breakdown voltages of $LN_2$ and $GN_2$ are investigated under AC voltage for Pressure ranging from 0 and 0.5 MPa. This research presented basis information of electrical insulation design for liquid nitrogen immersed HTS power apparatus.