• 제목/요약/키워드: Breakdown cause

검색결과 204건 처리시간 0.033초

Partial Discharge Measurements of Artificial Defects in HTS Transformer Model using HFCT

  • Lee, S.H.;Shin, W.J.;Park, T.G.;Koo, J.Y.;Lee, B.W.
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 2009
  • Partial discharge measurements in cryogenic dielectric materials of HTS transformer are very important because partial discharge was regarded as primary source for ageing and breakdown of cryogenic materials. But, partial discharge measurement techniques and its effects in low temperature high voltage environments were not suggested and there exist only a few reports on this research fields. Therefore, in order to implement reliable HTS transformers, partial discharge diagnosis techniques for cryogenic materials of HTS transformers were investigated using partial discharge (PD) pattern analysis methods. In this works, four different types of artificial defects including turn to turn insulation, free moving particle, void and protrusion, have been fabricated since it was commonly regarded that they might cause the sudden service failures of the power apparatus. For this purpose, these defects are installed into the dielectric materials in liquid nitrogen and experimental investigations have been carried out for the diagnosis of HTS transformer. And various PD patterns caused by the amount of quench of superconductors were analyzed. Throughout this works, the different PD patterns in cryogenic dielectric materials in liquid nitrogen, and PD measuring technique could be the fundamental steps to establish diagnosis technologies of HTS transformer for power applications.

  • PDF

지중송전선로 안전관리 방안 (OF케이블) (A Study on the Safety Checking and Testing method of the underground power transmission line (OF Cable))

  • 최종수;박강서;전준만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.429-434
    • /
    • 2009
  • 본 논문에서는 지중송전케이블의 안전관리방안에 대하여 정리하였고, 그에 따른 전기재해의 예방은 안정적인 전력공급과 설비운용에 있어 큰 비중을 차지한다. 최근 전력구내 OF케이블에서 화재가 발생하여 자칫 전력공급계통 마비로 이어져 광역정전과 심각한 사회문제를 초래시킬 수 있었던 바, 엄정한 검사를 통하여 이와 같은 유사사례 사고를 미연에 방지함은 물론 OF케이블에 대한 검사능력 배양과 선진기술 축적으로 향후 전기안전관리 향상 및 전기재해를 예방함으로써 안정적인 전력공급을 도모하기 위함이다.

  • PDF

전자빔 조사 폴리머의 전자 분포의 축퇴 과정 (Decay Process of Charge Distribution in E-beam Irradiated Polymers)

  • 최용성;김형곤;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.69-72
    • /
    • 2008
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

PMOS 소자가 삽입된 부분웰 구조의 N형 SCR 소자에서 정전기 보호 성능 향상을 위한 최적의 CPS 이온주입에 대한 연구 (Study on the Optimal CPS Implant for Improved ESD Protection Performance of PMOS Pass Structure Embedded N-type SCR Device with Partial P-Well Structure)

  • 양준원;서용진
    • 한국위성정보통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.1-5
    • /
    • 2015
  • PPS 소자가 삽입된 부분웰 구조의 N형 실리콘 제어 정류기(NSCR_PPS) 소자에서 정전기 보호 성능의 향상을 위한 CPS 이온주입조건의 최적화에 대해 연구하였다. 종래의 NSCR 표준소자는 on-저항, 스냅백 홀딩 전압 및 열적 브레이크다운 전압이 너무 낮아 정전기 보호소자의 필요조건을 만족시키지 못해 적용이 어려웠으나, 본 연구에서 제안하는 CPS 이온주입과 부분웰 이온주입을 동시에 적용한 변형 설계된 소자의 경우 스냅백 홀딩 전압을 동작전압 이상으로 증가시킬 수 있는 향상된 정전기 보호성능을 나타내어 고전압 동작용 마이크로 칩의 정전기보호 소자로 적용 가능함을 확인하였다.

NSCR_PPS 소자에서 채널차단 이온주입 변화에 따른 최적의 정전기보호소자 설계 (Optimal Design of ESD Protection Device with different Channel Blocking Ion Implantation in the NSCR_PPS Device)

  • 서용진;양준원
    • 한국위성정보통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.21-26
    • /
    • 2016
  • PPS 소자가 삽입된 N형 실리콘 제어 정류기(NSCR_PPS) 소자에서 채널차단영역의 이온주입 변화가 정전기 보호 성능에 미치는 영향을 연구하였다. 종래의 NSCR 표준소자는 on 저항, 스냅백 홀딩 전압 및 열적 브레이크다운 전압이 너무 낮아 마이크로칩의 정전기보호소자로 적용이 어려웠다. 그러나 본 연구에서 제안하는 채널 차단 영역의 이온주입 조건을 변화시켜 각각 변형설계된 소자에서는 채널 차단 이온주입이 정전기 보호성능의 향상에 영향을 주는 중요한 파라미터였으며, CPS_PDr+HNF 구조의 변형소자는 정전기보호소자의 설계창을 만족시키는 향상된 정전기보호성능을 나타내어 고전압 동작용 마이크로 칩의 정전기보호 소자로 적용 가능함을 확인하였다.

옥외용 실리콘 고무의 침식요인에 관한 연구 (The erosion factor of silicone rubber for outdoor use)

  • 서광석;김정호;이호열;박용관;양계준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.117-120
    • /
    • 1998
  • It is analyzed the erosing process of the polymeric insulator for outdoor use with the inclined plane method. Materials used are the different type of silicone rubber, they have the content of filler and component each other. As the content of filler added to improve the tracking and erosion resistance. It has the difference of electrical performance and erosion rate. The dry-band arc is also the parameter of accelerating erosion, and appear in the form of leakage current, and the activities of leakage current has a close relationship with the surface hydrophobicity. In this paper, the erosion growth is observed by measuring the time from the voltage application to the whole breakdown, and the erosion depth. In addition, it is measured the hydrophobicity and leakage current to be a cause of erosion by the erosion steps, studied SEM, EDX for observing the transformation of surface structure by erosing.

  • PDF

지중송전계통에서 절연접속함 위치 및 접지방식 변경의 효용성 평가 (Effectiveness Evaluation According to Change of IJ Joint Box Location and Grounding System in Underground Transmission System)

  • 고광만;이종범
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.247-253
    • /
    • 2015
  • Dielectric breakdown accidents have been mainly occurred in the vicinity of service entrance section in underground power transmission systems. One cause among them is due to the excessive component value of sheath located around service entrance of cable. In this paper, as one of the alternative to prevent these accidents, the change of cross bond grounding system and the location change of IJ(Insulation Joint) are suggested. Also, to evaluate effectiveness of this changing system, circulating current and induced voltage of sheath were analyzed in steady and transient state. By comparison of the analytical results for the several possible changing systems, a grounding system and location of IJ which has the smallest sheath component values is proposed. In this paper, analysis to evaluate the proposed system is carried out by EMTP/ATPDraw. It can be used as a valuable operational material to prevent accident of the service entrance section in underground power transmission system.

WEDM 가공특성에 대한 방전액의 전기전도율의 영향 (Electrical Conductivity of Dielectric on WEDM Characteristics)

  • 김창호;여홍태
    • 대한기계학회논문집A
    • /
    • 제27권10호
    • /
    • pp.1800-1808
    • /
    • 2003
  • This work deals with the electrical conductivity of dielectric on output parameters such as metal removal rate and surface roughness value of a carbon steel(SM25C) and sintered carbides cut by wire-electrical discharge machining(W-EDM). Dielectric has several functions like insulation, ionization, cooling, the removal of waste metal particles. The presence of minute particles(gap debris) in spark gap contaminates and lowers the breakdown strength of dielectric. And it is considered that too much debris in spark gap is generally believed to be the cause of arcing. Experimental results show that increases of cobalt amount in carbides affects the metal removal rate and worsens the surface quality as a greater quantity of solidified metal deposits on the eroded surface. Lower electrical conductivity of the dielectric results in a lower metal removal rate because the gap between wire electrode and workpiece reduced. Especially, the surface characteristics of rough-cut workpiece and wire electrode were analyzed too. Debris were analyzed also through scanning electron microscopy(SEM) and surface roughness tester. Micro cracks and some of electrode material are found on the workpiece surface by energy dispersive spectrometer(EDS).

362kV 50kA 다빈도 차단기 고장원인 분석 및 대책에 관한 연구 (A Study of Insulation Breakdown Cause Analysis and Measure of 362kV 50kA Circuit Breaker for Shunt Reactor Switching)

  • 최영성;전상동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.408-409
    • /
    • 2015
  • 한국전력공사에서는 2015년 4월말 기준 808개의 변전소를 운전 중에 있다. 변압기 용량으로 보면 299,734MVA에 달하고 있으며, 매년 증가하는 전력수요에 맞추어 신규 변전소 건설과 더불어 변전설비가 계속하여 확충되고 있다. 또한, 계절별 및 시간대별 부하변동에 따른 변전소 모선의 전압변동에 대응하기 위하여 Sh.C(Shunt Condenser), Sh.R(Shunt Reactor), SVC(Static Var Compensator) 등 다양한 무효전력보상 및 조절 설비들이 지속적으로 설치되고 있다. 이들 무효전력보상 설비들은 주로 변전소 모선에 전용 차단기를 통하여 연결되어 운전되고 있으며, 전용 차단기는 매일 시간대별 부하변동에 대응하여 개폐빈도가 많은 다빈도 차단기로서 잦은 개폐조작에 따른 내구성이 필요하며 변전소 모선전압을 기준전압 범위 이내로 안정적으로 유지하기 위한 신뢰성이 요구되고 있다. 본 논문에서는 345kV Sh.R 개폐용 동일유형의 345kV 50kA 1점절 다빈도 차단기에서 차단조작시 발생한 차단부 절연파괴 고장의 원인을 분석하고 재발방지를 위한 대책에 대하여 논하였다.

  • PDF

배전용 전력케이블 시스템 포괄진단 설비 개발 (Development of Global Insulation Assessment System for Medium Voltage power Cable System)

  • 이동영
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.66-72
    • /
    • 2003
  • 본 연구에서는 국내 배전계통에 사용 중인 전력케이블에 대한 평균열화평가시스템을 개발하였다. 절연진단의 최소한의 목적은 전력공급의 중단을 초래할 수 있는 열화 즉, 사고가능성이 논은 전력케이블을 효율적으로 선별하고 경제적으로 관리하는데 있다. 따라서 이러한 최소한의 진단 목표를 달성하기 위한 가장 효율적인 진단원리로 열화시정수법을 채택하고 감쇠전압을 측정변수로 하여 진단설비를 개발하였다. 현장적용성 시험 및 파괴강도 시험 결과 열화상태 평가결과와 파괴강도의 상관관계를 확인하였으며 본 연구를 통해 개발된 진단장치는 사고를 초래할 수 있는 열화의 효율적이고 경제적인 선별 및 관리에 유용한 설비가 될 수 있음을 알았다.