• 제목/요약/키워드: Break-In

검색결과 3,247건 처리시간 0.037초

소규모 농가에서의 농약의 사용 행태 및 방제복 착용현황에 대한 조사 (Current Attitudes of Pesticide Use and Protective Clothing in Smallholder Farmers of Korea)

  • 유경숙
    • 한국의류학회지
    • /
    • 제28권9_10호
    • /
    • pp.1292-1299
    • /
    • 2004
  • This survey was carried out on 256 smallholder farmers of the Jeonbuk Province to analyze their current behavior in pesticide usage and the use of protective clothing during spray work. The interviewees were at the age of about 50's in both males and females: they performed spray work mainly for their own farms. Many of them were not very well aware of the danger of pesticides and the adequate methods of pesticide handling. Water drinking and smoking during break time were the endangering factors of pesticide intoxication, reaching to 30-60% sprayers. Most of sprayers had experienced the exposures to pesticides during spray work and appealed some subjective clinical symptoms to the exposure, but they seldom sought medical treatments. More than 70% of respondents had not been wearing protective equipments during spray work. The results will be used as basic information in designing the improved protective clothing more acceptable by pesticide sprayers.

LSPM 동기전동기와 유도전동기의 특성 비교 (A Comparison of LSPM Synchronous Motor and Induction Motor)

  • 김병국;조원영;이인제;문지우;김미정;임성환;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.829-830
    • /
    • 2006
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

퍼지 전문가 시스템을 이용한 고장 예측 및 진단 (Fault Prediction and Diagnosis Using Fuzzy Expert System)

  • 최성운;이영석
    • 대한안전경영과학회지
    • /
    • 제1권1호
    • /
    • pp.7-17
    • /
    • 1999
  • As the loss from break-downs and errors, which became more frequent with the growth of elaborateness, complexity and in scale of the plant and equipments, are enormous, the improvement in the reliability, maintenance, safety, and qualify become to have interest. The fault diagnosis is a systematic and unified method to find errors, which is based on the interpretation that data, subconsciously, have noises. But, as most of the methods are inferences based on binomial logic, the uncertainty is not correctly reflected. In this study, we suggest, to manage the uncertainty in the system efficiently on the point of predictive maintenance, We should use fuzzy expert system, which make the decision considering uncertainty possible by taking linguistical variable and fixed quantity by using the fuzzy theory concepts on the basis of an expert's direct observation and experience.

  • PDF

고층 건물 경량화를 위한 첨단 복합재료 상판 (Advanced Composite Material Slabs for Tall Buildings)

  • 김덕현;심도식;김성환
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.126-133
    • /
    • 1997
  • For each construction material used, there is certain theoretical limit in sizes. For tall building construction, the reduction in slab weight is the first step to take in order to break such size limits. In this paper, the feasibility of such objective is proven and given by numerical analysis result. For a typical building slab, both concrete and advanced composite sandwich panels are considered. The concrete slab is treated as a special orthotropic plate to obtain more accurate result. For each panel, the deflection under the dead and live loads is compared, since both tensile and compressive strengths of the composites are far more higher than those of concrete. All types of sandwich panels considered, except one case, have weights less than one tenth of that of reinforced concrete slab, with deflections less than that of the concrete slab. The cost analysis result and manufacturing methods will be reported later.

  • PDF

IMPROVEMENT OF ANAEROBIC DIGESTION RATE OF BIOSOLIDS IN WASTE ACTIVATED SLUDGE(WAS) BY ULTRASONIC PRETREATMENT

  • Oh, Sae-Eun
    • Environmental Engineering Research
    • /
    • 제11권3호
    • /
    • pp.143-148
    • /
    • 2006
  • The ultrasonics is a new technology in waste activated sludge(WAS) treatment. Ultrasonic treatment is well known method for the break up of microbial cells to extract out a variety of intercellular materials inside microorganism cell. This study was done to investigate the effects of the ultrasonic frequency and power on disruption of biosolids in WAS and to examine the effect on methane production of WAS treated by ultrasonics. Biosolids disruption with ultrasound is more effective at ultrasonic frequency of 40 kHz and power of 0.3 watt/mL. In the digestion with WAS pretreated by sonication time for 10 minute at 40 kHz and 0.3 watt/mL, the total quantity of generated methane increased by 75%, as compared with experimental control(non-treatment).

소형 밀폐형 이상 열싸이펀에서 삽입 세선이 기포상승에 미치는 영향 (Effect of a Thin Wire Insert on the Bubble Rise in a Miniature Tow-Phase Closed Thermosyphon)

  • 김원태;이윤표
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.99-109
    • /
    • 1996
  • Experimental investigations are carried out for the characteristics of bubble rise in the Miniature Two-Phase closed Thermosyphon(MTPCT) with a thin wire insert. The working fluids applied as experimental media are of three kinds: water, methanol, and ethanol. The effects of combination of the inclination with diametric ratio $\alpha$(=d$_{0}$/D$_{I}$) on rising velocity of a large bubble in the thermosyphon are explicitly analyzed. The realm of a movable bubble and the critical value of $\alpha$ are iteratively pursued to interpret the region Figures-of-Break, rooted in the governing physics relations, according to the application of working fluid. Experimental results are compared with those of analysis and critical ranges for $\alpha$ and D$_{I}$ were ascertained from comparisons.isons.

  • PDF

휨시험에 의한 에폭시 균열주입제의 변형특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Deformation of Repaired Epoxy Resin by Flexural Strength Test)

  • 김재성;배준영;김경덕;강석표;곽주호;김정환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.269-272
    • /
    • 2005
  • Epoxy resins are gradually becoming some of the most important and versatile polymers in modem civil engineering. Because epoxy resins have some unigue properties, such as toughness, versatility of viscosity and curing conditions, good handling characteristics, high adhesive strength, inertness, low shrinkage compared to most other thermo-setting resins and concrete, and resistance to chemicals, they have found many applications in construction castings, repair materials, road or bridge deck pavements, coatings, and as structural or non structural adhesives. In this applications, epoxy resins are widely used for polymer concretes, grouting materials, injection glues, and sealants. In this paper, characteristics of deformation of repair material after repaired have been investigated by viscosity of repair material and the width of crack. It is believed that flexural strength of epoxy resin with low viscosity is high because tensile strength is high and elongation at break is low, fracture energy is low.

  • PDF

FRP Rods로 보강한 콘크리트 보의 전단 내하력의 평가 (Estimation of Shear Carrying Capacity on Concrete Beams, Reinforced with FRP Rods)

  • 최익창;연준희;고재용
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 2004
  • The purpose of this study is to estimate the contribution of concrete and shear reinforcement, in shear carrying capacity, on concrete beams, reinforced with steel and/or FRP rods. The experimental tests for 12 concrete beams, reinforced with steel and/or FRP rods, are carried out. Experimental parameters includes the mechanical properties of reinforcements in shear and bending, and the ratio of shear reinforcement. This study compares the experimental results of shear carrying capacity in concrete beams, reinforced with steel and/or FRP rods, with the proposed equations. According to the experimental results, the effect of the concrete in concrete beams reinforced with FRP rods is decreased with decreasing Young's modulus of longitudinal tensile reinforcement. This results from the large deflection of concrete beams reinforced with decreasing Young's modulus of longitudinal tensile reinforcement. Also, the contribution of shear reinforcement is smaller than the calculated value, using the truss analogy. This results from the fact that the stress redistribution is not exhibited after the break of shear reinforcement.

직류방식 전기철도에서 강제배류기의 절연협조 (Insulation Coordination of Forced Drainage in Electric Railway)

  • 민병훈;어익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 1999
  • The forced drainage set up to decrease the cathodic protection in each kind of steel conduit laid under the ground is so proscribed to be maintained less than 60V in its output voltage that insulation coordination is easy to be left out of account, on the basis of 60V of working voltage. When railway or subway break down during the service of a subway, 1,500 voltage approximating to line voltage flows through the load terminal of the drainage (rail and underground conduit) though momentary in the worst case. And so, an accident followed by dielectric breakdown, fire and damage by a fire is expected. Therefore, I suggest that insulation coordination should be considered against such a thing on designing, producing and setting up forced drainage.

  • PDF

수차발전기 회전자 Coil 이탈 원인분석 및 방지대책 (The Preventive measure and the cause analysis for field coils breaking away from the rotor in hydro generator)

  • 김승효;문형태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1021-1023
    • /
    • 2000
  • This paper presents the preventive measure and the cause for field coils breaking away from the rotor, which lately occurred when No.1 hydro generator was operating in Chung-Ju Dam No.2 Hydro Power Station. In findings, we ascertained the truth of contact between rotor rim and field coils, and think that field coils will break away from the rotor because of mechanical stress according as continuous operation after completion. 1985. Therefore, we conclude that the preventive measure for such a phenomenon is that stopper should be installed between rotor rim and field coils, and bolts should be tightened because of operating characteristic however there are not the design standards for installing stopper in generator rotor internationally.

  • PDF