• Title/Summary/Keyword: Break area

Search Result 314, Processing Time 0.034 seconds

Criteria for Determining Working Area and Operating Cost for Long-Term Lease of Agricultural Machinery

  • Shin, Seung Yeoub;Kang, Chang Ho;Yu, Seok Cheol;Kim, Yu Yong;Noh, Jae Seung
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: This research suggests a method of establishing criteria for working area and operating cost for a long-term lease of agricultural machinery. Methods: Eight crops were selected-three food crops and five open-field vegetables-and agricultural machines used for sowing, transplanting, and cultivation in dry-field farming were analyzed. Results: The break-even acreage for agricultural machinery under a long-term lease was found to differ by agricultural machine, ranging from 1.0 to 5.8 ha. In terms of arable land area, the break-even acreages for harvesting machinery and transplanters were 15.6 to 26.1 ha and 6.1 to 8.6 ha, respectively. The working area lessees should secure was divided into two cases: (1) 2.0 to 11.6 ha when leasing individual agricultural machines (sowing and transplanting) for a long-term period, and (2) more than 10 ha when farmers who cultivate beans, potatoes, garlic, onions, and so on lease sowing and transplanting machines as a set. When agricultural machinery was leased for a long term, the operating cost and working time were reduced by 27.6 to 74.4% and 2.5 to 21.6%, respectively, indicating considerable effect. Conclusions: A long-term lease project needs to be promoted to overcome the limitation of short-term leases of agricultural machinery. The local government should lead this project and facilitate the mechanization of dry-field farming. The department in charge of agricultural machinery lease projects needs to set the working area to cover the rate and maintenance cost for farmers who lease agricultural machinery for the long term.

A Forecasting Model for the Floodwave Propagation from the Hypothetical Earth Dam-Break (Earth Dam의 가상파괴로 인한 홍수파의 예측모형)

  • Lee, Jong Tae;Han, Kun Yeun;Lee, Jung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.6 no.4
    • /
    • pp.69-78
    • /
    • 1986
  • The floodwave propagation resulting from the earth dam-break is studied. DBF(Dam-Break Floodwave) model based on the dynamic wave equation is presented by introducing Preissmann scheme and double sweep algorithm. DBF model is applied to the Teton dam, and the numerical results have good agreements with the data observed in the peak elevation profile, the peak discharge, the flood travel time and the flooded area.

  • PDF

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

Development of Numerical Model to Analyze Levee Break (하천제방붕괴 해석모형의 개발)

  • Park, Jae-Hong;Han, Kun-Yeun;Ahn, Ki-Hong
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.571-578
    • /
    • 2009
  • Levee-break Analysis model is developed to predict the variation of breach width according to time and to estimate inundation area and depth in protected lowland. This Model calculate flood depth using 4 point implicit finite difference method in river channel and analyze breach flow based on physical theory introducing soil transport equation and erosion process. Breach analysis model and channel flood model are combined into Levee-Break Model and this model is applied to actual levee break case. Then, this model can simulate reasonably many levee-break parameters such as river stage, breach width, breach formation and so on. If the applicability of this model is proved through applications to more various actual levee-break cases, the suggested model is expected to do more accurate flood analyses on levee break site.

Implementation of Preceding Vehicle Break-Lamp Detection System using Selective Attention Model and YOLO (선택적 주의집중 모델과 YOLO를 이용한 선행 차량 정지등 검출 시스템 구현)

  • Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • A ADAS(Advanced Driver Assistance System) for the safe driving is an important area in autonumous car. Specially, a ADAS software using an image sensors attached in previous car is low in building cost, and utilizes for various purpose. A algorithm for detecting the break-lamp from the tail-lamp of preceding vehicle is proposed in this paper. This method can perceive the driving condition of preceding vehicle. Proposed method uses the YOLO techinicque that has a excellent performance in object tracing from real scene, and extracts the intensity variable region of break-lamp from HSV image of detected vehicle ROI(Region Of Interest). After detecting the candidate region of break-lamp, each isolated region is labeled. The break-lamp region is detected finally by using the proposed selective-attention model that percieves the shape-similarity of labeled candidate region. In order to evaluate the performance of the preceding vehicle break-lamp detection system implemented in this paper, we applied our system to the various driving images. As a results, implemented system showed successful results.

A Numerical Study on Propagation Characteristics of Dam-break Wave through a Porous Structure (다공성 구조물을 통과하는 댐 붕괴파의 전파특성에 관한 수치적 연구)

  • Jeong, Woochang
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.1
    • /
    • pp.11-24
    • /
    • 2014
  • In this study, the characteristics of the propagation of dam-break wave through a porous structure in a water tank is numerically analyzed by using the three-dimensional numerical model (ANSYS CFX model). As results of comparison between the existing measured and simulated water depth distributions in and around a porous structure, the agreement is relatively well satisfied. Moreover, for the case of the presence in part of a porous structure in a water tank, the three-dimensional flow structure is numerically analyzed In general, compared with in the area with a porous structure, the abrupt variation of water depth occurs in the area without a porous structure. It is shown that the porous structure can play a role to decrease the abrupt variation of water depth.

LOS and NLOS Path-loss Characteristics at 3.4, 5.3, and 6.4 ㎓ in an Urban Environment (3.4, 5.3, 6.4 ㎓ 대역 신호의 가시 및 비가시 구간에서의 경로손실 특성)

  • 조한신;박병성;육종관;박한규;이정수
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.127-131
    • /
    • 2002
  • This paper presents the a measured path-loss characteristics in urban line-of-sight(LOS) and non line-of-sight(NLOS) environments for 3.4, 5.3, and 6.4 ㎓ band signals. A two-ray model is applied to analyse the path-loss characteristics in LOS areas. In LOS areas, an empirical break point, whose distance is shorter than a theorical break point, is founded. Further, a sudden power level drop occurs at a transition point from LOS region to NLOS area and different path-loss exponents are occured various cases. The power level drop due to comer loss and path-loss exponents both increase as the distance between the transmitter and the corner increases.

  • PDF

Evaluation of the TEXAS-V Fragmentation Models Against Experimental Data

  • Song Jin H.;Park Ik K.;Nilsuwankosit Sunchai
    • Nuclear Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.276-284
    • /
    • 2004
  • This paper presents the results of the TEXAS-V computer code simulations of FARO L-14, L-28, and L-33. The old break-up model and new break-up model are tested to compare the respective simulations of each. As these experimental data sets cover a wide range of ambient pressures, sub-cooling of the water pool, and the melt jet diameters, the results of the simulations will be beneficial in assessing the TEXAS-V code's capability to predict the steam explosion phenomena in a prototypical reactor case. The current model was found to have some deficiencies, and the modules for the fragmentation, the equation of state, and the interfacial area for each flow regime in TEXAS-V were improved for the simulation of FARO L28 and FARO L-33.

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.