• 제목/요약/키워드: Brazed Part

검색결과 8건 처리시간 0.014초

이종재 브레이징 접합계면의 응력해석 (The Stress Analysis of Dissimilar Materials in Brazed Interface by BEM)

  • 오환섭;김시현;김성재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.769-772
    • /
    • 1997
  • In this study, By employing two dimensional(2-D) Boundary Element Method(BEM) stress analysis was carried to investigate stress distributions on the brazing joint of a Hardmetal and a HSS. Two model was proposed to analyze stress singularity in brazed interface. The stress results from the BEM were considered influence of the kind of materials , thickness of filled metal and length of vertical brazing adhesive. From those obtained results , the peak point of stress was founded in the lower part of two interface was made by brazing. As the thickness and length changed, the maximum stress tended to change in the peak point.

  • PDF

Al-Si계 필러메탈을 이용한 A1050알루미늄의 브레이징 접합조건에 관한 연구 (A Study on the Brazing Bondinf Conditions of A1050 Using Al-Si Alloy Filler Metal)

  • 김정일;김영식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권1호
    • /
    • pp.66-72
    • /
    • 1993
  • The brazing of Al to Al using Al-Si alloy filler metal was performed under different bonding conditions such as ratio of lap length to plate thickness, surface roughness and joint clearance of the lap joint. The adopted thickness of the base metal in this experiments were two kinds of 4mm and 7mm which were most commonly used in various field. Influence of several bonding conditions of Al/Al joint was quantitavely evaluated by bonding strength test, and microstructural analysis at the interlayer were performed by optical microscope. From above experiments, the optimum bonding conditions of the brazing bonding of Al/Al using Al-Si alloy filler metal was determined. The major results obtained are as follows. 1) The fracture occurs at brazed joint in the conditions of that the ratio of lap length to plate thickness is less than 2 in case of 7mm plate thickness. 2) The ratio of lap length to plate thickness which the fracture occurs at base metal is decreased with the decreasing of the plate thickness. 3) The joint strength is not affected by the surface roughness and joint clearance of the brazed part. 4) The heat-treatment of the brazed joint contribute to eliminate the boundary between the base metal and filler metal. However, the joint strength is not affected by the heat-treatment.

  • PDF

WBK 의 구조적 특성에 대한 와이어 굴곡 효과 (Effect of Strut Waviness on Structural Performance of Wire-Woven Bulk Kagome Cores)

  • 이기원;강기주
    • 대한기계학회논문집A
    • /
    • 제35권9호
    • /
    • pp.1099-1103
    • /
    • 2011
  • 기존의 WBK(와이어 직조 카고메)의 기계적 강도와 강성은 WBK 를 구성하는 요소가 반듯하다는 가정 아래에서 계산되었다. 실제 WBK 의 요소는 3 차원 나선형상을 이루고 있어 계산된 이론 해와 실험 결과값과 차이를 보인다. 이번 연구에서는 정확한 WBK 의 기계적 강도와 강성을 위해 하나의 트러스 요소의 굴곡 효과와 브레이징 접합 부를 고려하여 계산하였다. 또한 예측한 이론 해의 검증을 위한 경계주기조건(PBC) 유한요소해석을 수행하여 실험 결과값과 비교 분석하였다.

LTCC/Kovar 간의 Brazing 특성 연구 (Study on the Brazing Characteristics of LTCC/Kovar)

  • 이우성;조현민;임욱;유찬세;이영신;강남기
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 추계 기술심포지움 논문집
    • /
    • pp.57-57
    • /
    • 2000
  • 본 논문에서는 MCM 및 패키지의 Lid로 사용되는 합금인 Kovar (Fe-Ni-Co alloy) 와 LTCC (Low Temperature Co-fired Ceramics) 간의 Brazing 특성을 연구하였다. 기존에 사용되고 있는 알루미나 패키지의 경우, 주로 80$0^{\circ}C$ 이상의 온도에서 Brazing을 실시하고 있으며, 조성은 Ag-Cu 계열을 사용하고 있다. 하지만, LTCC 의 경우, 소결온도가 85$0^{\circ}C$ 내외로서 기존의 방법을 그대로 적용하기는 어려움이 있다. 또한 Brazing 특성에 따른 접착 강도는 Brazing Alloy 의 영향뿐만 아니라 LTCC 와 전도체 전극사이의 Metallization 에 크게 영향을 받는다. 따라서, 본 논문에서는 Brazing Alloy의 종류 (Ag-Cu, Au-Sn) 및 Brazing 조건에 따른 Brazing 특성뿐만 아니라, 전도체 전극내 유리질 함량에 따른 Brazing 특성을 평가하여 LTCC/Kovar 간의 최적의 Brazing 조건을 구현하고자 하였다.

  • PDF

대향류 핀삽입형 재생증발식 냉방기의 냉방성능 (Cooling Performance of a Counterflow Regenerative Evaporative Cooler with Finned Channels)

  • 문현기;이대영
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.462-469
    • /
    • 2008
  • A regenerative evaporative cooler has been fabricated and tested for the evaluation of cooling performance. The regenerative evaporative cooler is a kind of indirect evaporative cooler comprised of multiple pairs of dry and wet channels. The air flowing through the dry channels is cooled without any change in the humidity and at the outlet of the dry channel a part of air is redirected to the wet channel where the evaporative cooling takes place. The regenerative evaporative cooler fabricated in this study consists of the multiple pairs of finned channels in counterflow arrangement. The fins and heat transfer plates were made of aluminum and brazed for good thermal connection. Thin porous layer coating was applied to the internal surface of the wet channel to improve surface wettability. The regenerative evaporative cooler was placed in a climate chamber and tested at various operation condition. The cooling performance is found greatly influenced by the evaporation water flow rate. To improve the cooling performance, the evaporation water flow rate needs to be minimized as far as the even distribution of the evaporation water is secured. At the inlet condition of $32^{\circ}C$ and 50%RH, the outlet temperature was measured at $22^{\circ}C$ which is well below the inlet wet-bulb temperature of $23.7^{\circ}C$.

Cu-Si계 삽입금속을 사용한 페라이트계 스테인리스강의 아크 브레이징에서 인장성질에 미치는 입열량의 영향 (Effect of the Heat Input on the Tensile Properties in Arc Brazing of Ferritic Stainless Steel using Cu-Si Insert Alloy)

  • 김명복;김상주;이봉근;원신건;윤병현;우인수;강정윤
    • 대한금속재료학회지
    • /
    • 제48권4호
    • /
    • pp.289-296
    • /
    • 2010
  • The effects of heat input and different microstructureswere investigated on the tensile-shear properties of an arc-brazed joint of theferritic stainless steel 429EM using a Cu-Si insert alloy. The brazing speed was fixed at 800 mm/min whilethe brazing current varied from 80 to 120A. For abrazing current lower than 100A, fracturing occurred at the joint root in the direction perpendicular to the tensile load. As the brazing current increased to 120A, fracturing occurred at the base metal or the joint root. The joint and the base metal had very similar yield and tensile load values. However, the amount of elongation was decreased considerably compared to when the base metal was used. The fracturing began at the triple point of the root part and was classified into three types. The difference in the tensile-shear properties was closely related to the three fracture types.

핵연료조사리그 계장선 통과부위의 밀봉을 위한 유도 브레이징 시스템 개발 (Development of Induction Brazing System for Sealing Instrumentation Feedthrough Part of Nuclear Fuel Test Rig)

  • 홍진태;김가혜;허성호;안성호;정창용;손광재;정양일
    • 대한기계학회논문집A
    • /
    • 제37권12호
    • /
    • pp.1573-1579
    • /
    • 2013
  • 핵연료의 연소성능을 시험하기 위해서는 시험 루프에 설치된 조사리그 내에 냉각수가 순환되도록 설계되어야 한다. 이때, 조사리그 내 냉각수는 $300^{\circ}C$, 15.5 MPa 의 고온 고압으로 순환시키기 때문에 냉각수의 밀봉은 핵연료 조사리그를 제작할 때 가장 중요한 공정 중 하나이다. 특히 15 개의 계장선이 조사리그의 압력경계부위를 통과하게 되는데, 이의 밀봉을 위해 일반적으로 브레이징 공정이 적용된다. 본 연구에서는 조사리그 브레이징용 진공챔버 및 고주파 유도가열기를 포함하는 유도 브레이징 시스템을 개발하고, 다양한 실험을 통해 산화막이 발생하지 않는 공정변수를 검토하였으며, 브레이징 제품의 인장시험, 단면검사, 밀봉성능검사 등을 통해 브레이징 공정의 건전성과 밀봉성능을 검증하였다.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.