• 제목/요약/키워드: Branch Type Runner System

검색결과 7건 처리시간 0.025초

편측 분기형 러너 배열을 가진 다수 캐비티 사출금형에서의 충전 불균형도 (The Filling Imbalance in Multi-Cavity Injection Molds with Unary Branch Type Runner Lay-out)

  • 강철민;정영득
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.72-75
    • /
    • 2003
  • Almost all injection molds have multi-cavity runner system for productivity and are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, filling imbalances have been observed though geometrically balanced runner lay-out are used. Generally, these filling imbalances are due to thermal unbalance, viscosity, characteristic of polymers and so on. These kinds of filling imbalances has already been reported by Beaumont[1] since 1997. In this study, we presented filling imbalaces in balanced runner that has unnary branch type lay-out through experimental tests. As a result of experiments, we could present the processing conditions for the balanced filling in geometrically balanced runner that has unnary branch type lay-out

  • PDF

편측 분기형 러너 배열을 가진 다수 캐비티 사출금형에서의 충전 불균형도 (The Filling Imbalance in Multi-Cavity Injection Molds with Unary Branch Type Runner Lay-out)

  • 강철민;정영득
    • 소성∙가공
    • /
    • 제13권7호
    • /
    • pp.580-585
    • /
    • 2004
  • Almost all injection molds have multi-cavity runner system fur productivity and are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, filling imbalances have been observed though geometrically balanced runner lay-out. Generally, these filling imbalances are due to thermal unbalance, viscosity, characteristic of polymers and so on. These kinds of filling imbalances have already been reported by Beaumont since 1997, but his research has mainly focused on filling imbalance at binary runner. In this study, we conducted an experimental study about the filling imbalances in unary branch runner as well as binary branch runner and inquired into the causes of filling imbalances. The results could be summarized as fellowing: Filling imbalances existed in multi-cavity mold with unary branch runner, it could be decreased by optimizing processing condition such as increasing injection rate, and it is almost proportion to each polymer's temperature sensibility.

나뭇가지형 러너시스템을 갖는 사출금형에서의 충전 불균형 (Filling Imbalance in Injection Mold with Branch Type Runner System)

  • 한동엽;정영득
    • Design & Manufacturing
    • /
    • 제1권1호
    • /
    • pp.45-50
    • /
    • 2007
  • Recently, the study for filling imbalance in thermoplastic polymer has gradually been increased. However, it is hard to find the researches for filling imbalance of thermoplastic elastomer(TPE). The experiment of filling imbalance was conducted for thermoplastic vulcanize(TPV) and PP, ABS polymers in the mold with un-geometrically balanced runner system(Branch Type Runner System). In this experiment, the effects of the melt temperature, injection pressure and injection speed on the filling imbalance were investigated.

  • PDF

사출금형의 러너시스템 형상에 따른 균형 충전도 (Degree of Filling Balance according to Runner Shapes in Injection Mold)

  • 한동엽;정영득
    • 한국정밀공학회지
    • /
    • 제25권10호
    • /
    • pp.144-149
    • /
    • 2008
  • Configuration of filling imbalance which is originated from imbalanced share rate of melt on runner is changed by runner layout, runner shape, material property, injection pressure, injection speed, melt temperature and mold temperature. In this paper, we conducted a study of runner layout and shape that are main factors of filling imbalance. Other factors such as the sharp corner effect and the groove corner effect are recently released were also considered. The results of study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Especially, this study suggests a new runner system for filling balance by adapting the two effects of unary branch type runner at multi cavity mold and theoretical investigated flow in the sharp corner type runner.

사출금형의 러너시스템 형상에 따른 균형 충전도 (Degree of Filling Balance according to Runner Shapes in Injection Mold)

  • 한동엽;정영득
    • Design & Manufacturing
    • /
    • 제6권1호
    • /
    • pp.52-57
    • /
    • 2012
  • Aspect of filling imbalance that is originated from imbalanced share rate in runner is changed by material property, runner layout that are factors of changing viscosity and by injection pressure, injection speed, melt temperature and mold temperature that are injection conditions. In this paper, we made a study of runner system that is one of factor of filling imbalance and Sharp Conner Effect and Groove Corner Effect that are recently released. The study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Also, we suggested runner system for filling imbalance by adapting the two effects at multi cavity of unary branch type and theoretical investigated flow in the Shrap Conner runner type.

  • PDF

편측 분기형 러너시스템을 가진 사출금형에서 엘라스토머 TPV의 충전 불균형 (Filling Imbalance of Elastomer TPVs in Injection Mold with Unary Branch Type Runner System)

  • 한동엽;정영득
    • 한국정밀공학회지
    • /
    • 제25권4호
    • /
    • pp.47-52
    • /
    • 2008
  • Recently, the study for filling imbalance in thermoplastic polymer has gradually been increased. However, it is hard to find the researches for filling imbalance of thermoplastic elastomer(TPE). The experiment of filling imbalance was conducted for the three kinds of thermoplastic vulcanizes(TPVs) and PP polymer in the mold with geometrically balanced runner system(Unary Branch Type Runner System). In this experiment, the effects of the melt temperature, injection pressure and injection speed on the filling imbalance were investigated. There was also the imbalance in TPV injection molding process as well as in conventional injection molding with plastics. The tendency of filling imbalance in TPV injection molding specially decreased by taking place the hesitation of TPV melt.

편측 분기형 러너시스템을 가진 사출금형에서 엘라스토머 TPV의 충전 불균형 (Filling imbalance of elastomer TPVs in injection mold with unary branch type runner system)

  • 한동엽;박태원;정영득
    • Design & Manufacturing
    • /
    • 제2권4호
    • /
    • pp.5-10
    • /
    • 2008
  • Recently, the study for filling imbalance in thermoplastic polymer has gradually been increased. However, it is hard to find the researches for filling imbalance of thermoplastic elastomer(TPE). The experiment of filling imbalance was conducted for the three kinds of thermoplastic vulcanizes(TPVs) and PP polymer in the mold with geometrically balanced runner system(Unary Branch Type Runner System). In this experiment, the effects of the melt temperature, injection pressure and injection speed on the filling imbalance were investigated. There was also the imbalance in TPV injection molding process as well as in conventional injection molding with plastics. The tendency of filling imbalance in TPV injection molding specially decreased by taking place the hesitation of TPV melt.

  • PDF